1. Introduction
This manual provides essential information for the safe and efficient operation, installation, maintenance, and troubleshooting of your Jiayin JYPC-4 Electromagnetic Pump. This self-priming pump is designed for applications requiring precise fluid metering, such as in coffee machines. Please read this manual thoroughly before use and retain it for future reference.

2. Safety Instructions
WARNING: Always disconnect the power supply before performing any installation, maintenance, or troubleshooting procedures.
- Power-Off Operation: Disconnect power supply before any shutdown or intervention.
- No Dry Running: Do not operate the pump without liquid. Dry running can cause severe damage to the pump.
- Liquid Only: Use only clean, particle-free liquid to prevent clogging and damage to internal components.
- Choking Hazard (Small Parts): This product contains small parts. Not suitable for children under 3 years.
Please observe all local and national safety regulations when installing and operating this device.
3. Installation (Setup)
3.1. Mounting
- Vertical Mounting: Ensure stable and upright installation to optimize pump performance and longevity.
3.2. Connections
- Inlet/Outlet Sealing: Ensure all connections at the inlet and outlet are properly sealed to prevent liquid leakage.
- Inlet Filtration: Install a suitable filter at the inlet to remove impurities from the liquid, protecting the pump from damage and clogging.
3.3. Electrical Connection
The pump operates on AC 220V-240V, 50Hz. Ensure your power supply matches these specifications. A wiring diagram is typically provided with the product for correct electrical connection. If a visual wiring diagram is not available, consult a qualified electrician for installation.
4. Operation
Once properly installed and connected, the Jiayin JYPC-4 pump is designed for continuous operation within its specified parameters. Ensure the liquid supply is clean and consistent. Avoid operating the pump dry, as this will lead to immediate damage.

5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your pump.
- Filter Cleaning: Periodically inspect and clean the inlet filter to prevent blockages and maintain efficient flow.
- Seal Inspection: Check seals for wear and tear. Replace worn seals to prevent leaks and maintain pressure.
- Tubing Inspection: Ensure all tubing is securely tightened and free from kinks or damage.
- Pump Cleaning: If the pump is used with liquids that may leave residue, periodic cleaning of the pump's internal components may be necessary.
6. Troubleshooting
Refer to the table below for common issues and their solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No Liquid Output | Air in system, clogged filter, no power supply | Bleed air from the system, clean the inlet filter, check power supply connections. |
| Low Pressure | Worn seals, loose tubing, debris in pump | Replace seals, tighten tubing connections, remove any debris from the pump. |
| Excessive Noise | Loose mounting, dirty pump, worn plunger | Reinforce mounting, clean the pump, replace the plunger if worn. |
7. Specifications
The following table details the technical specifications of the Jiayin JYPC-4 Electromagnetic Pump:

| Parameter Item | Parameter Value |
|---|---|
| Product Model | JYPC-4 |
| Maximum Pressure | 2.5 bar |
| Average Flow Rate | 200 cc/min |
| Rated Voltage | 220V ~ 50Hz |
| Rated Power | 22W |
| Noise Level | 54 dB |
| Power Source | Electric |
| Application | Metering |
| Theory | Electromagnetic Pump |
| Structure | Self-Priming Pump |
| Standard or Nonstandard | Standard |
| Pressure | Low Pressure |
| Usage | Water |
| Origin | China Mainland |
| Certification | None |
8. User Tips
- For optimal performance, ensure the pump is always supplied with clean, filtered water.
- Regularly check for any signs of leakage around connections and address them promptly.
- If the pump is integrated into an appliance, ensure the appliance's power requirements match the pump's specifications.
- Store the pump in a dry, clean environment when not in use for extended periods.
9. Warranty & Support