Myoslim 15 Tesla 6500W Muscle Stimulator RF Body Sculpting Machine

Contents

Myoslim Muscle Stimulator RF Body Sculpting Machine User Manual

Model: 15 Tesla 6500W Muscle Stimulator RF Body Sculpting Machine

Brand: Myoslim

1. General Information

The EMSZERO series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.

Advanced HI-EMT Technology:

The EMSZERO series employs advanced HI-EMT technology, utilizing high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth, and deep internal structural reshaping.

Touch-Controlled Display:

The touch-controlled display significantly simplifies device operation, allowing clear visibility of information from various positions. The brightness of the display is adjustable to accommodate different office lighting conditions. User-friendly, the screen guides you throughout the entire treatment process.

Real-time Monitoring and Guidance:

Throughout the treatment process, the display shows remaining treatment time, utilized channels and treatment methods, applied treatment types, attachments used, and other necessary information. This aids users in real-time monitoring of treatment progress and provides necessary guidance.

Upgradeability:

As your therapeutic needs evolve, you may wish to upgrade your equipment later on. The EMSZERO series offers flexible upgrade options to meet your future treatment requirements.

1.1 Indications for Use

EMSZERO is intended to be used for:

  1. Improvement of abdominal tone, strengthening of the abdominal muscles, and development of a fitter abdomen.
  2. Strengthening, toning, and firming of buttocks, thighs, and calves.
  3. Improvement of muscle tone and firmness, for strengthening muscles in arms.

1.2 Operating Environment

The operating environment of the EMSZERO instrument series is crucial to ensuring the effectiveness and safety of the device.

  • Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
  • Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
  • Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
  • Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
  • Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
  • Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
  • Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.

1.3 Patient Profile

This machine is suitable for patients who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.

1.5 Contraindications

Contraindications for use include:

  • Wounds on the skin (or avoiding wounds when using)
  • Patients with heart disease (such as those with arrhythmias), especially those with pacemakers
  • Cancer patients
  • Patients with infectious diseases
  • Pregnant women, lactating women, menstrual period
  • Major surgery patients, diabetic patients
  • Having any metal in the body
  • People with cerebrovascular disease (stroke patients)

1.6 Possible Side Effects

These effects may include but are not limited to:

  • Muscle soreness
  • Reduction in muscle fat
  • Temporary muscle spasms
  • Transient joint or muscle tendon pain
  • Localized redness or skin flushing

2. Safety Precautions and Warnings

Precautions before use:

  • Do not use when feeling full; wait at least one hour after meals.
  • Before using the instrument, remove any metal jewelry you are wearing.
  • Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
  • Start at the lowest intensity level and gradually increase it according to the user's skin tolerance.
  • It is forbidden to eat or drink during the operation. Try to eat at least one hour after the operation.

3. Device and Accessories

3.1 Front and Rear Panel of the Main Unit

Front view of the instrument:

Front view of the EMSzero main unit with two handles and a display screen.

Figure: Front view of the EMSzero main unit, showing the display screen, EMS handles, and power switch.

Note: The handle can only be used by the original machine and cannot be used interchangeably.

Rear view of the instrument (Magnetic thin handle plug):

Rear view of the EMSzero main unit showing handle connections, power input, and switches.

Figure: Rear view of the EMSzero main unit, detailing the handle connections, power plug, and switch.

3.2 Handle

Diagram of a single EMSzero handle.

Figure: Diagram of a single EMSzero handle.

3.3 List of Accessories

SerialNameQuantityPicture
1Host1 setEMSzero host unit
2Handle2EMSzero handle
37*100CM belt2
4Power cable1
5Electronic manual1 copy

4. Device Installation

1. Handle Film Application

Diagram illustrating the application of protective film to the handle.

Figure: Apply the black protective film to the working part of the handle.

2. Installing the Handle

Diagram showing how to install the handles onto the main unit.

Figure: Align the hole and fasten the clip, then lock the key ring to secure the handle connection.

3. Connecting Power

Diagram for connecting the power cable to the machine and the socket.

Figure: Connect one end of the power cord to the machine and the other end to the socket.

4. Pressing the Back Switch

Diagram showing the location and function of the back power switch.

Figure: The back switch controls the main power. Ensure the light is on for power on, and off for power off.

5. Pressing the Front Switch

Diagram showing the location and function of the front power button.

Figure: Single-click the front button to power on. Long press to power off.

5. Basic Device Operation

5.1 Handle Exchange

The handle must be calibrated every time it is installed or replaced.

Warning: When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

5.2 Device Start Up/Shut Down

  1. Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
  2. Move the manual switch on the rear panel to the "o" position.
  3. Press the button on the front panel.
  4. When the treatment is finished, press and hold the power button to turn off the machine.

5.3 Navigation Controls

5.3.1 Setting the Therapy by Controls

Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:

Screenshot of the EMSzero control screen showing two handles and basic settings.

Figure: Control screen showing navigation controls, channel selector, stop therapy, start/pause therapy, and therapy parameter settings.

5.4 Unit Settings

Mode 1 Operation Interface:

Screenshot of the EMSzero control screen for Mode 1 operation.

Figure: Mode 1 operation interface. Remove the handle from the frame, fix it with the belt to the target area. Frequency for Mode 1 is 5-60Hz.

Mode 1 Detailed Settings:

Screenshot of the EMSzero control screen for detailed Mode 1 settings.

Figure: Adjust handle operation time and intensity. Click start/stop to begin. The work button suspends the work, and the back button returns to the previous screen.

Mode 2 Operation Interface:

Screenshot of the EMSzero control screen for Mode 2 operation.

Figure: Mode 2 operation interface. Remove the handle from the frame, fix it with the belt to the target area. Frequency for Mode 2 is 30-100Hz.

Mode 2 Detailed Settings:

Screenshot of the EMSzero control screen for detailed Mode 2 settings.

Figure: Adjust intensity/stage frequency/time for Mode 2. Click start/pause to begin or pause. The back button returns to the previous screen.

Language Settings:

Screenshot of the EMSzero control screen showing language settings.

Figure: Screen for selecting the device language.

Sound Adjustment:

Screenshot of the EMSzero control screen showing sound adjustment.

Figure: Screen for adjusting the device sound volume.

Brightness Adjustment:

Screenshot of the EMSzero control screen showing brightness adjustment.

Figure: Screen for adjusting the display brightness.

Set Date and Time:

Screenshot of the EMSzero control screen showing date and time settings.

Figure: Screen for setting the current date and time.

System Adjustment and Technician Settings: These sections allow for advanced system configurations and access for technical personnel, often password-protected.

6. Therapy

6.1 Preparing the Therapy

  1. Communicate with patients.
  2. Ensure good health.
  3. Stay hydrated.
  4. Wear appropriate clothing.
  5. Avoid eating in large quantities.
  6. Familiarize yourself with the treatment process.
  7. Avoid drinking alcohol.

6.2 Placing the Handle

Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.

The handles can be placed on various body areas:

  • Belly: Handles are placed on the abdominal area.
  • Buttock: Handles are placed on the gluteal muscles.
  • Arm: Handles are placed on the arm muscles.
  • Thigh: Handles are placed on the thigh muscles.
  • Calf: Handles are placed on the calf muscles.
  • Arse: Handles are placed on the gluteal area.

Video: Demonstration of applying the EMSzero handles to the abdomen and operating the device.

7. Maintenance and Repair

7.1 Maintenance

7.1.1 Daily Inspection

Managers must regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.

7.1.2 Cleaning

Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off.

7.1.3 Replacing the Fuse

When replacing the fuse, in order to prevent electric shock, please turn off the power and unplug the power plug. The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included.

8.2 Cleaning of the Surface of the Device

The logo of the machine is silk screen printed. The rest of the parts are spray painted. Please use cotton paper towels or ordinary toilet paper moistened with water to wipe clean; do not use alcohol-based detergents.

8.3 Cleaning of Accessories that Come into Contact with Patient

The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.

8.4 Storage

The instrument should be stored in the original packaging box, placed in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C, and the relative humidity should not be greater than 93%. It is not allowed to be placed near harmful gases, flammable, or explosive substances and corrosive gases.

8.6 Common Faults and Troubleshooting Methods

Fault PhenomenonCausesExclusions and Workarounds
Device not workingThe power plug is not inserted into the socket
Power switch not on
Power fuse failure
Check the power
Check the power switch
Replace the fuse
Handle not workingCheck the handle for loose connectionReseat the handle

9. Technical Parameters

NameSpecification
Brand Namemyoslim
Item TypeMassage & Relaxation
Power SupplyAlternating Current (AC110V-220V 50/60Hz)
MaterialCotton, ABS
Hand InstrumentYes
ElectronicNo
High-concerned chemicalNone
Output maximum power0-6000W
Frequency5-200HZ
Energy Intensity15 Tesla
MAX FREQUENCY200HZ
TechnologyHigh-Intensity Focused Electromagnetic (HIEMT)+RF
NameEMSzero Body Shaping Machine
Target AreaBody, Legs/Arms, Abdomen, Hips
FunctionWeight Loss, Cellulite Reduction, Body Slimming, Fat Burning
Featurebody contouring, body slimming, body sculpt, muscle build, fat removal, skin tight, butt lift, muscle build, muscle stimulation, EMS Cellulite Reductions
LanguagesChinese, English, Japanese, Portuguese, Korean, Spanish, French, Russian
ServiceSupport customized logo
ApplicationFor Home Use, For Commercial
Screen size7.0 inches
Machine colorWhite

9.1 Electromagnetic Compatibility (EMC)

Radiated Electromagnetic Field Immunity Test:

  • Port: Enclosure
  • Basic Standard: IEC 61000-4-3:2020
  • Test Level: 30V/m with 80% AM. 1kHz Modulation.
  • Standard require: A
  • Tester: Sam Liu
  • Temperature: 25°C
  • Humidity: 54%

Test Equipment:

DescriptionManufacturerModelIdentifierCal. DateCal. Due
Signal GeneratorIFA2023BN/A15/03/202214/03/2023
Power AmplifierAR150W1000N/A15/03/202214/03/2023
Power AntennaAR25S1G4AN/A15/03/202214/03/2023

Block Diagram of Test Setup:

The block diagram illustrates a 7x4x3 meter chamber with an EUT (Equipment Under Test) and support. A signal generator and power amplifier feed into a power antenna. The EUT is monitored using a camera, and a PC controller manages the signal generator and power amplifier from a control room. The setup includes measurements for height (1.5M) and distance (3M, 0.8M).

User Tips

  • For best results, commit to multiple sessions, especially for stubborn areas like the abdomen and thighs.
  • The device's cooling system is effective, ensuring smooth operation without overheating.
  • The treatments offer progressive and natural results, making it suitable for professional use in salons.
  • The EMSzero machine can be highly effective for postpartum repair and local shaping.
  • The pads adhere well, and intensity levels are suitable for various users, including beginners.

Frequently Asked Questions (FAQ)

Q: What languages does the device support?
A: The device supports Chinese, Japanese, Korean, French, Spanish, Portuguese, English, and Russian.
Q: Does this machine come with a 110V US plug?
A: Yes, the machine can be equipped with a 110V US plug.
Q: Can I purchase additional handles (leg and arm), or a pelvic floor handle later?
A: Yes, you can purchase extra handles, including leg & arm handles and a pelvic floor handle, at a later time if needed.

10. Warranty and Manufacturer

Warranty Information

The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) if it has an intact appearance.

The main machine is guaranteed for one year (excluding fragile parts and other non-warranty scope or expired warranty period). Maintenance and updates are available, with maintenance fees charged appropriately.

If the instrument is broken and needs to be sent back for repair, the buyer shall bear the return shipping cost within six months from the date of purchase, and the seller shall bear the shipping-in cost. After six months, the buyer shall bear all shipping costs.

Free warranty service is not provided for failures caused by personal reasons, including:

  • Faults caused by unauthorized disassembly and modification of this product.
  • Faults caused by accidental fall.
  • Failure caused by lack of reasonable maintenance.
  • Failure to operate according to the correct instructions in this instruction manual.

For detailed warranty terms, please refer to the official user manual PDF: View User Manual (PDF)

11. Manufacturer

Guangzhou Xinwei Electronic Technology Co., Ltd.