1. Introduction
This manual provides instructions for the installation, operation, maintenance, and troubleshooting of the G3/4 2 Way Water Inlet N/C Normal Closed Pressure Electric Solenoid Valve, model FCD-180B. Solenoid valves are automated basic components that electromagnetically control fluids. They are designed to adjust the direction, flow, speed, and other parameters of the medium in industrial control systems and are also suitable for household appliances.
Figure 1: G3/4 Solenoid Valve, highlighting arbitrary angle installation.
2. Safety Information
- Ensure the power supply is disconnected before installation or maintenance.
- Verify that the voltage of the solenoid valve matches your power supply (AC 220V).
- Do not exceed the specified water pressure range (0.02-0.8MPa).
- Installation should be performed by qualified personnel if you are unsure.
- Avoid exposing the valve to temperatures outside the 0-40°C range.
3. Package Contents
Upon unpacking, please ensure all items are present and undamaged:
- 1 x Solenoid Valve (FCD-180B)
4. Specifications
| Feature | Specification |
|---|---|
| Model Number | FCD-180B |
| Material | Brass |
| Rated Voltage | AC 220V (50-60Hz) |
| NC or NO | Normally Closed |
| Actuator Mode | Without Manual And Instruction |
| Structure | Control |
| Port Size | G3/4 |
| Media | Water |
| Temperature of Media | Medium Temperature (0-55°C) |
| Power | Solenoid |
| Standard or Nonstandard | Standard |
| Pressure | High Pressure (0.02-0.8MPa) |
| Environmental Condition | Altitude ≤ 2500m |
| Environment Temperature | 0-40°C |
| Air Relative Humidity | < 95% (at 25°C) |
| Working Mode | Only work under water pressure |
| Working Method | Short-term quota system (intermittent periodic duty-type) |
| Insulation Class | Class E |
| Applicable Fluid | Water (0-55°C) |
| Flow Rate (L/min) | > 5 > 11 > 18 > 32 (Corresponding Water Pressure) |
| Life Span | More than 100,000 times |
| Weight | Approx. 230g |
| Power Source | AC |
| Is Smart Device | No |
| Origin | Mainland China |
| Certification | NONE |
5. Setup and Installation
The solenoid valve is designed for easy installation and can be installed at an arbitrary angle. It is cast with high-quality brass material, ensuring precision and reliability. It is also moisture-proof and anti-corrosion with high-temperature resistance.
- **Preparation**: Ensure the water supply is turned off and the system is depressurized before beginning installation.
- **Orientation**: The valve can be installed at any angle. Observe the flow direction arrow on the valve body to ensure correct orientation in your piping system.
- **Connection**: Connect the G3/4 threaded ends of the valve to your water pipes. Use appropriate sealing tape (e.g., PTFE tape) on the threads to ensure a watertight seal.
- **Electrical Wiring**: Connect the AC 220V power supply to the solenoid coil terminals. Ensure proper insulation and secure connections.
- **Testing**: Slowly turn on the water supply and check for any leaks. Then, apply power to the solenoid valve to verify it opens, and remove power to verify it closes.
Figure 2: Example of solenoid valve installation in a pipe system.
Figure 3: Detailed views of the solenoid valve, including the internal filter screen.
6. Operation
This is a Normally Closed (N/C) solenoid valve. This means:
- When no power is applied to the coil, the valve remains closed, preventing fluid flow.
- When AC 220V power is applied to the coil, the valve opens, allowing fluid to flow through.
- The valve is designed for a short-term quota system (intermittent periodic duty-type) and only works under water pressure.
7. Maintenance
The solenoid valve is designed for sustainable use and requires minimal maintenance. Regular checks can help ensure its longevity and proper function:
- **Periodic Inspection**: Periodically inspect the valve for any signs of leaks, corrosion, or damage to the wiring.
- **Cleaning**: If the valve's performance degrades, it may be due to debris in the water. Disconnect power and water supply, then carefully disassemble the valve to clean any internal screens or passages. Reassemble securely.
- **Environmental Conditions**: Ensure the valve operates within the specified environmental temperature and humidity ranges to prevent premature wear.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Valve does not open when powered |
|
|
| Valve does not close when power is removed |
|
|
| Buzzing noise and pipe vibration |
|
|
| Reduced flow rate |
|
|
9. User Tips
- This valve is confirmed to be Normally Closed (N/C), meaning it opens when power is applied and closes when power is removed.
- It can be effectively integrated with a 220V smart switch for automated control in home automation systems.
- Ensure adequate water pressure for optimal operation, as some users have noted it performs best at higher pressures.
10. Frequently Asked Questions (FAQ)
- Q: What is the thread specification of the product?
- A: The product features a regular G3/4 thread.
- Q: Does the valve open when current is applied and close when there is no current?
- A: Yes, this is a Normally Closed (N/C) valve. It opens when power is applied and closes automatically when power is removed.
11. Warranty and Support
For any issues or questions not covered in this manual, please contact the seller or manufacturer for support. Keep your purchase receipt for warranty claims.
A detailed user manual in PDF format is available for download at User Manual (PDF).