Aramox FCD-180B

Contents

G3/4 2 Way Water Inlet N/C Normal Closed Pressure Electric Solenoid Valve FCD-180B

Model: FCD-180B | Brand: Aramox

1. Introduction

This manual provides instructions for the installation, operation, maintenance, and troubleshooting of the G3/4 2 Way Water Inlet N/C Normal Closed Pressure Electric Solenoid Valve, model FCD-180B. Solenoid valves are automated basic components that electromagnetically control fluids. They are designed to adjust the direction, flow, speed, and other parameters of the medium in industrial control systems and are also suitable for household appliances.

Solenoid valve with text 'Can be installed by arbitrary angle'

Figure 1: G3/4 Solenoid Valve, highlighting arbitrary angle installation.

2. Safety Information

  • Ensure the power supply is disconnected before installation or maintenance.
  • Verify that the voltage of the solenoid valve matches your power supply (AC 220V).
  • Do not exceed the specified water pressure range (0.02-0.8MPa).
  • Installation should be performed by qualified personnel if you are unsure.
  • Avoid exposing the valve to temperatures outside the 0-40°C range.

3. Package Contents

Upon unpacking, please ensure all items are present and undamaged:

  • 1 x Solenoid Valve (FCD-180B)

4. Specifications

Feature Specification
Model NumberFCD-180B
MaterialBrass
Rated VoltageAC 220V (50-60Hz)
NC or NONormally Closed
Actuator ModeWithout Manual And Instruction
StructureControl
Port SizeG3/4
MediaWater
Temperature of MediaMedium Temperature (0-55°C)
PowerSolenoid
Standard or NonstandardStandard
PressureHigh Pressure (0.02-0.8MPa)
Environmental ConditionAltitude ≤ 2500m
Environment Temperature0-40°C
Air Relative Humidity< 95% (at 25°C)
Working ModeOnly work under water pressure
Working MethodShort-term quota system (intermittent periodic duty-type)
Insulation ClassClass E
Applicable FluidWater (0-55°C)
Flow Rate (L/min)> 5 > 11 > 18 > 32 (Corresponding Water Pressure)
Life SpanMore than 100,000 times
WeightApprox. 230g
Power SourceAC
Is Smart DeviceNo
OriginMainland China
CertificationNONE

5. Setup and Installation

The solenoid valve is designed for easy installation and can be installed at an arbitrary angle. It is cast with high-quality brass material, ensuring precision and reliability. It is also moisture-proof and anti-corrosion with high-temperature resistance.

  1. **Preparation**: Ensure the water supply is turned off and the system is depressurized before beginning installation.
  2. **Orientation**: The valve can be installed at any angle. Observe the flow direction arrow on the valve body to ensure correct orientation in your piping system.
  3. **Connection**: Connect the G3/4 threaded ends of the valve to your water pipes. Use appropriate sealing tape (e.g., PTFE tape) on the threads to ensure a watertight seal.
  4. **Electrical Wiring**: Connect the AC 220V power supply to the solenoid coil terminals. Ensure proper insulation and secure connections.
  5. **Testing**: Slowly turn on the water supply and check for any leaks. Then, apply power to the solenoid valve to verify it opens, and remove power to verify it closes.
Solenoid valve installed in a pipe system

Figure 2: Example of solenoid valve installation in a pipe system.

Collage showing various views of the solenoid valve, including the internal filter screen.

Figure 3: Detailed views of the solenoid valve, including the internal filter screen.

6. Operation

This is a Normally Closed (N/C) solenoid valve. This means:

  • When no power is applied to the coil, the valve remains closed, preventing fluid flow.
  • When AC 220V power is applied to the coil, the valve opens, allowing fluid to flow through.
  • The valve is designed for a short-term quota system (intermittent periodic duty-type) and only works under water pressure.

7. Maintenance

The solenoid valve is designed for sustainable use and requires minimal maintenance. Regular checks can help ensure its longevity and proper function:

  • **Periodic Inspection**: Periodically inspect the valve for any signs of leaks, corrosion, or damage to the wiring.
  • **Cleaning**: If the valve's performance degrades, it may be due to debris in the water. Disconnect power and water supply, then carefully disassemble the valve to clean any internal screens or passages. Reassemble securely.
  • **Environmental Conditions**: Ensure the valve operates within the specified environmental temperature and humidity ranges to prevent premature wear.

8. Troubleshooting

Problem Possible Cause Solution
Valve does not open when powered
  • No power supply or incorrect voltage.
  • Debris obstructing the valve mechanism.
  • Insufficient water pressure.
  • Check power connections and ensure AC 220V.
  • Clean the valve internals.
  • Ensure water pressure is within 0.02-0.8MPa.
Valve does not close when power is removed
  • Debris obstructing the valve mechanism.
  • Coil malfunction.
  • Clean the valve internals.
  • Contact support for coil replacement.
Buzzing noise and pipe vibration
  • Loose mounting or pipe connections.
  • Water hammer or flow turbulence.
  • Ensure valve and pipes are securely mounted.
  • Consider installing a water hammer arrestor or flow restrictor if necessary.
Reduced flow rate
  • Debris in the valve or pipes.
  • Valve passage hole is small (inherent design).
  • Clean the valve and check for pipe blockages.
  • Note that the valve has a specific flow rate; if higher flow is needed, a different valve might be required.

9. User Tips

  • This valve is confirmed to be Normally Closed (N/C), meaning it opens when power is applied and closes when power is removed.
  • It can be effectively integrated with a 220V smart switch for automated control in home automation systems.
  • Ensure adequate water pressure for optimal operation, as some users have noted it performs best at higher pressures.

10. Frequently Asked Questions (FAQ)

Q: What is the thread specification of the product?
A: The product features a regular G3/4 thread.
Q: Does the valve open when current is applied and close when there is no current?
A: Yes, this is a Normally Closed (N/C) valve. It opens when power is applied and closes automatically when power is removed.

11. Warranty and Support

For any issues or questions not covered in this manual, please contact the seller or manufacturer for support. Keep your purchase receipt for warranty claims.

A detailed user manual in PDF format is available for download at User Manual (PDF).

© 2024 Aramox. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.