WESA BZ-05-HUI

Contents

WESA Double Power Socket User Manual

Model: BZ-05-HUI

1. Introduction

This manual provides instructions for the safe installation, operation, and maintenance of your WESA Double Power Socket. Please read this manual thoroughly before installation and keep it for future reference.

WESA Grey Double Power Socket front view

Figure 1: WESA Double Power Socket (Front View)

2. Safety Information

WARNING: Risk of electric shock. Installation should only be performed by a qualified electrician or a person with appropriate electrical knowledge.

  • Always disconnect power at the main circuit breaker or fuse box before installing or servicing the socket.
  • Ensure all wiring connections are secure and correctly insulated.
  • Do not install in wet or damp locations unless specifically rated for such environments.
  • Do not exceed the rated current or voltage of the socket.
  • Keep children away from electrical outlets.

3. Package Contents

Please check the package for the following items:

  • 1 x WESA Double Power Socket Unit
  • Mounting Screws (typically included)

If any items are missing or damaged, please contact your retailer.

4. Setup and Installation

This socket is designed for wall-embedded installation. Follow these steps carefully:

  1. Power Disconnection: Turn off the main power supply to the circuit at your electrical panel. Verify that the power is off using a voltage tester.
  2. Prepare the Wall Box: Ensure you have a standard wall-mounted electrical box installed in your desired location.
  3. Wiring Connections:
    WESA Double Power Socket dimensions and wiring diagram

    Figure 2: Product Dimensions and Rear View with Wiring Terminals

    Refer to Figure 2 for the terminal layout. Connect the electrical wires as follows:

    • Connect the Live (Phase) wire (usually brown or red) to the terminal marked 'L'.
    • Connect the Neutral wire (usually blue or black) to the terminal marked 'N'.
    • Connect the Ground (Earth) wire (usually green/yellow) to the terminal marked with the ground symbol (⌂).
    • Ensure all wire ends are stripped to the appropriate length (approx. 10-12mm) and securely fastened in their respective terminals.
  4. Mounting: Carefully place the wired socket into the wall box. Use the provided mounting screws to secure the socket to the wall box. Do not overtighten.
  5. Install Faceplate: Attach the decorative faceplate to the socket unit.
  6. Power Restoration: Turn the main power supply back on at your electrical panel.
  7. Testing: Test the socket with a known working appliance to ensure proper functionality.

For detailed wiring diagrams and local electrical codes, consult a qualified electrician or refer to the official user manual PDF: WESA Double Power Socket User Manual PDF.

5. Operating Instructions

Once installed and power is restored, the WESA Double Power Socket operates like any standard electrical outlet. Simply plug your EU-standard electrical appliances into the sockets. Ensure the appliance's power requirements do not exceed the socket's rated capacity.

6. Maintenance

  • Cleaning: To clean the socket, first ensure power is disconnected. Wipe the surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as this may damage the finish or internal components.
  • Inspection: Periodically inspect the socket for any signs of damage, loose connections, or discoloration. If any issues are found, disconnect power and consult a qualified electrician.

7. Troubleshooting

ProblemPossible CauseSolution
No power from the socket.
  • Circuit breaker tripped or fuse blown.
  • Loose wiring connection.
  • Faulty appliance.
  • Check and reset the circuit breaker or replace the fuse.
  • Disconnect power and check wiring connections (consult an electrician).
  • Test with a different appliance.
Socket feels warm.
  • Overloaded circuit.
  • Loose connection.
  • Unplug some devices.
  • Disconnect power and check wiring connections (consult an electrician). If warmth persists, discontinue use and seek professional help.

If troubleshooting steps do not resolve the issue, or if you are unsure about performing any electrical work, please contact a qualified electrician.

8. Specifications

Brand:WESA
Model Number:BZ-05-HUI
Rated Current:16A
Socket Type:EU Standard (220V)
Installation Type:Wall Embedded
Material:Plastic (Flame Retardant)
Grounding:Standard Grounding
Number of Slots:2
Standard Dimensions:104mm x 83mm x 38mm (4.09in x 3.26in x 1.49in)
Certification:CE, RoHS, WEEE
Origin:Mainland China

9. User Tips

  • Always ensure the appliance plug is fully inserted into the socket to prevent arcing and overheating.
  • Avoid overloading the socket by plugging in too many high-power devices simultaneously.
  • For a clean aesthetic, ensure the wall box is flush with the wall surface before mounting the socket.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or your point of purchase. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.