1. Introduction
This manual provides comprehensive instructions for the safe and effective use of the MASTFUYI Smart Digital Multimeter (Models FY107A, FY107B, FY107C). This device is designed for electrical measurements, offering a wide range of functions including AC/DC voltage, resistance, capacitance, continuity, diode, frequency, temperature, non-contact voltage (NCV) detection, and live wire checking. Its smart auto-ranging feature simplifies operation, making it suitable for both professionals and DIY enthusiasts.

2. Safety Information
Always adhere to safety precautions when using electrical testing equipment. Failure to do so may result in electric shock, fire, or personal injury. Keep this manual for future reference.
2.1 General Safety Guidelines
- Do not exceed the maximum input values specified for each function.
- Ensure the test leads are properly connected and in good condition before use.
- Do not use the multimeter if it appears damaged or if the battery cover is not properly closed.
- Avoid using the device in wet environments or during electrical storms.
- Always disconnect power to the circuit under test before making resistance, capacitance, or continuity measurements.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC, as these pose a shock hazard.
3. Product Overview and Parts
The MASTFUYI Smart Digital Multimeter is designed for ease of use and durability. Familiarize yourself with its components:

3.1 Key Components
- Display Screen: Large LCD for clear readings.
- Function Buttons: SEL (Select), HOLD, NCV, LIVE.
- Power Button: On/Off switch.
- Input Jacks: COM (Common), INPUT (for voltage, resistance, capacitance, frequency, diode, continuity, temperature).
- NCV Sensor: For non-contact voltage detection.
- Flashlight: For illuminating work areas.
- Battery Compartment: Located on the back.
4. Setup and Preparation
4.1 Package Contents
Upon opening the package, ensure all items are present:

- MASTFUYI Smart Digital Multimeter
- Test Leads (Red and Black)
- Temperature Probe (for models with temperature function)
- User Manual
- Storage Bag
4.2 Battery Installation
The multimeter requires AAA 1.5V batteries (typically 2 or 3, depending on the model). To install:
- Locate the battery compartment on the back of the multimeter.
- Unscrew the battery cover and remove it.
- Insert the batteries, ensuring correct polarity (+ and -).
- Replace the battery cover and secure it with the screw.
4.3 Connecting Test Leads
Connect the test leads to the appropriate input jacks:
- Insert the black test lead into the "COM" (Common) jack.
- Insert the red test lead into the "INPUT" jack for most measurements (voltage, resistance, capacitance, frequency, diode, continuity, temperature).
5. Operating Instructions
The MASTFUYI Smart Digital Multimeter features an "Auto" mode for simplified operation, automatically detecting the measurement type. You can also manually select functions using the "SEL" button.
5.1 Power On/Off
Press the red power button to turn the multimeter on or off. The device will display "Auto" upon startup.
5.2 AC/DC Voltage Measurement
To measure voltage:
- Ensure the multimeter is in "Auto" mode or manually select voltage mode using the "SEL" button.
- Connect the test leads in parallel to the circuit or component you wish to measure.
- The display will show the voltage reading (AC or DC) and frequency (for AC).


5.3 Resistance Measurement
To measure resistance:
- Ensure the circuit is de-energized.
- Connect the test leads across the component.
- The multimeter will display the resistance value in Ohms (Ω).
5.4 Capacitance Measurement
To measure capacitance:
- Ensure the capacitor is discharged before testing.
- Connect the test leads across the capacitor terminals.
- The display will show the capacitance value in Farads (F).
5.5 Continuity Test
For continuity testing:
- Ensure the circuit is de-energized.
- Connect the test leads across the circuit path or component.
- A continuous beep indicates a complete circuit (low resistance).
5.6 Diode Test
To test a diode:
- Ensure the diode is isolated from the circuit.
- Connect the red lead to the anode and the black lead to the cathode.
- A forward voltage drop will be displayed. Reverse the leads; an open circuit (OL) should be displayed.
5.7 Temperature Measurement
For models equipped with a temperature probe:
- Connect the temperature probe to the input jacks.
- Select the temperature function (if not in auto mode).
- Place the probe on or in the object to be measured. The temperature will be displayed in Celsius (°C) and Fahrenheit (°F).
5.8 Non-Contact Voltage (NCV) Detection
To detect AC voltage without contact:
- Press the "NCV" button.
- Move the top of the multimeter near the conductor.
- The screen will indicate "---" for low voltage and "----" for high voltage, accompanied by an audible alarm.

5.9 Live Wire Checking
To identify live wires:
- Press the "LIVE" button.
- Insert the red test lead into the socket or touch the conductor.
- The screen will display "LIVE" and an alarm will sound if a live wire is detected.
5.10 Additional Functions
- HOLD: Press the "HOLD" button to freeze the current reading on the display. Press again to release.
- Backlight: The display has a backlight for use in low-light conditions.
- Flashlight: Activate the built-in flashlight for illuminating dark work areas.
- Auto Power Off: The multimeter will automatically power off after a period of inactivity to conserve battery life.
6. Maintenance
6.1 Cleaning
Wipe the multimeter casing with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and free from scratches.
6.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Follow the battery installation steps in Section 4.2.
6.3 Storage
If the multimeter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Multimeter does not power on. | Dead or incorrectly installed batteries. | Check battery polarity or replace with new batteries. |
| Inaccurate readings. | Low battery, incorrect mode selection, or damaged test leads. | Replace batteries, ensure correct mode, check test leads for damage. |
| "OL" (Overload) displayed. | Measurement exceeds the device's range or an open circuit. | Ensure the measurement is within the specified range. For continuity/resistance, check for an open circuit. |
| No NCV detection. | NCV function not activated or weak signal. | Press the NCV button to activate. Ensure the sensor is close to the AC voltage source. |
8. Specifications
| Feature | Specification |
|---|---|
| Is Smart Device | Yes |
| DIY Supplies | Electrical |
| Measuring Capacitance Range | 10nF-60mF |
| Measuring Resistance Range | 50Ω-60MΩ |
| AC Voltage | 100mV-750V |
| DC Voltage | 100mV-1000V |
| Certification | CE, FCC |
| Origin | Mainland China |
| Package Length | 20 cm |
| Package Width | 12 cm |
| Package Height | 5 cm |
| Package Weight | 0.287 kg |
9. User Tips
- The multimeter's "Auto" function is highly convenient. It automatically detects the type of measurement (voltage, resistance, continuity) and selects the appropriate range, eliminating the need for manual range selection. This simplifies testing and speeds up your work.
10. Warranty and Support
This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For detailed warranty information, technical support, or service inquiries, please refer to the official product documentation or contact the seller directly.