AIFEN 868D

Contents

AIFEN-868D Hot Air Rework Station User Manual

Model: 868D

1. Safety Precautions

Pay attention to the safety precautions below before using this de-soldering station.

  1. Follow the manual to use this de-soldering station. DO NOT use it for unspecified purposes.
  2. The air outlet and its nearby areas are extremely hot. Be careful so as not to be burnt.
  3. In the idle state, the handle must be placed on the handle rack in a correct manner. DO NOT place it on the working station or another place. After the job is done, allow the de-soldering station to cool down below 100°C (entering into the sleeping mode) before turning off the power switch.
  4. Keep the air outlet unblocked. Any blockage must be cleared.
  5. DO NOT place a sharp object on the air outlet hose as the latter may be damaged.
  6. When using this de-soldering station, maintain at least 2mm between the air outlet and the target item.
  7. Different wind nozzles with slightly different temperatures can be selected for different applications.
  8. If this de-soldering station will be not used for a long time, pull out the power plug.
  9. Handle the de-soldering station with care. DO NOT tap on the handle or violently shake the station.
  10. Regularly check and maintain this station. DO NOT use it when it has damages, especially when the power cable or air gun handle wire is damaged.
  11. DO NOT use this station when it is wet or when your hands are wet; otherwise you may risk a short circuit or electric shock.
  12. DO NOT use this station near inflammable gases or other combustible substances. After using this station, DO NOT place it around inflammable gases or other combustible substances immediately.
  13. The wall surface, ceiling, floor, arch bar and other places may contain combustible substances. Using the de-soldering station in these places may ignite these substances, which can be difficult to discover and thus may result in property loss or casualties. When working in these places, move the hot air de-soldering handle back and forth wherever possible. The handle's lingering or pause at a position may ignite the combustible substances near this position.
  14. Children are unaware of how dangerous electric products can be. DO NOT use or store this station in a place accessible to a child. DO NOT allow a child to get near or touch this station.

2. Product Overview

2.1. Product Features

  • Multiple protection functions and key functions for enhanced safety and usability.
  • Real-time operation facilitated by a magnetic switch control lever; placing the handle in its holder immediately initiates hibernation.
  • Automatic sleep function allows parameters to be set while in a dormant state.
  • Sensor closed-loop, microcomputer zero-trigger temperature control ensures quick heating, stable and precise temperature adjustment, free from wind influence.
  • Vortex brushless fan provides adjustable air flow over a wide range, adaptable to various uses.
  • Automatic cooling function extends the life of the heating element and protects the hot air handle.

2.2. Applications

  • Suitable for dismantling and soldering a variety of components such as SOIC, CHIP, QFP, PLCC, BGA, etc.
  • Ideal for thermal shrinkage, baking, paint removal, adhesive removal, unfreezing, pre-heating, sterilization, and plastic soldering.
  • Adjustable air volume extends its applicable range to applications requiring small or large air volume.
  • Suitable for lead-free hot air de-soldering applications.

2.3. Components

The AIFEN-868D Hot Air Rework Station includes the main unit, hot air gun, various nozzles, and a handle holder.

AIFEN-868D Hot Air Rework Station with hot air gun and nozzles

Figure 1: AIFEN-868D Hot Air Rework Station with main unit, hot air gun, and included nozzles.

Control panel of AIFEN-868D showing LED display, temperature and air volume adjustment buttons, and power switch

Figure 2: Front panel of the AIFEN-868D, showing the LED display for temperature and air volume, adjustment buttons, and power switch.

Various hot air nozzles including cyclone and straight air types with different diameters (7mm, 10mm, 12mm)

Figure 3: Included hot air nozzles, featuring both cyclone and straight air types in various sizes (7mm, 10mm, 12mm).

3. Setup

3.1. Initial Setup

  1. Place the desoldering station on a flat, stable work surface.
  2. Select the appropriate air nozzle for your task and install it onto the hot air gun. For general use, a larger size air nozzle is often recommended.
  3. Place the hot air gun handle securely in its holder on the side of the main unit.
  4. Connect the power cord to the station and then to a suitable power outlet.

3.2. Temperature Unit Conversion

To switch between Celsius (°C) and Fahrenheit (°F):

  • With the machine powered off, press and hold the "TEMP ▲" button.
  • While holding the button, turn on the power switch.
  • The machine will directly convert and display the temperature unit.

4. Operating Instructions

4.1. Basic Operation

  1. Turn on the power switch.
  2. Remove the hot air gun handle from its holder. The system will enter normal working mode, and the temperature will stabilize. The display will show the "set temperature" and "actual temperature".
  3. After completing your work, place the handle back into its holder. The station will automatically enter cold air cooling mode for the heating element.
  4. Once the temperature drops below 100°C, the station will enter sleep mode.
  5. If the station will not be used for a long time, turn off the power switch.

Note: To prolong the life of the heating element and protect IC chips, use the lowest effective temperature and highest possible air volume for your task.

4.2. Temperature and Air Volume Settings

4.2.1. Temperature Setting

  • Increase Temperature: Press "TEMP ▲" once to increase by 1°C. Press and hold "TEMP ▲" for rapid increase until released.
  • Decrease Temperature: Press "TEMP ▼" once to decrease by 1°C. Press and hold "TEMP ▼" for rapid decrease until released.

4.2.2. Air Volume Setting

  • Increase Air Volume: Press "AIR ▲" once to increase by 1 level. Press and hold "AIR ▲" for rapid increase until released.
  • Decrease Air Volume: Press "AIR ▼" once to decrease by 1 level. Press and hold "AIR ▼" for rapid decrease until released.

4.2.3. Temperature Calibration

If calibration is needed:

  • With the machine powered off, press and hold both "TEMP ▲" and "TEMP ▼" buttons simultaneously.
  • While holding the buttons, turn on the power switch. This will enter the temperature calibration interface.
  • Use the "TEMP ▲" and "TEMP ▼" buttons to adjust the temperature.
  • After 5 seconds of inactivity, the machine will automatically save the setting and exit calibration mode.

4.3. Sleep Mode

The station features an automatic sleep function to save energy and prolong component life.

  • Entering Sleep: When the hot air gun handle is placed correctly in its holder, the system automatically initiates large air volume cooling. Once the display temperature falls below 100°C, the system enters sleep mode.
  • Waking from Sleep: Simply remove the hot air gun handle from its holder, and the system will immediately enter the working state, heating up to the set temperature.

5. Maintenance

5.1. Heating Element Replacement

Important: Always ensure the station is cooled down and powered off before attempting to replace the heating element.

  1. Loosen the handle's anti-scalding sheath on the hot air gun and remove it.
  2. Unscrew the three screws that secure the steel pipe (which contains the heating element).
  3. Carefully remove the old heating element.
  4. Install the new heating element, ensuring it is properly seated, and reassemble the handle in reverse order.
Diagram showing the components of the hot air gun handle: handle sheath, handle shell, heater parts, and handle line

Figure 4: Exploded view of the hot air gun handle, illustrating the heating element (heater parts) and other components for replacement.

Note: The steel pipe of this product may show slight yellowing after high-temperature aging (over 500°C). This is normal aging and does not affect performance.

5.2. General Cleaning

  • Keep the air outlet unblocked. Regularly check for and clear any blockages.
  • Wipe the exterior of the station with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Regularly inspect the power cable and hot air gun handle wire for any damage. Do not use the station if any damage is found.

6. Troubleshooting

This section addresses common issues you might encounter with your AIFEN-868D Hot Air Rework Station.

ProblemPossible CauseSolution
Station does not power on.No power supply; power switch off; faulty power cord.Check power connection; ensure power switch is ON; inspect power cord for damage.
Hot air gun not heating.Heating element failure; loose connection; station in sleep mode.Remove handle from holder to wake from sleep; check connections; replace heating element if faulty.
Air flow is weak or inconsistent.Air outlet blocked; fan malfunction.Clear any blockages from the air outlet; ensure air volume setting is appropriate.
Temperature display is inaccurate.Needs calibration.Perform temperature calibration as described in Section 4.2.3.

If you encounter issues not listed here or if the suggested solutions do not resolve the problem, please contact customer support.

7. Specifications

ParameterValue
Power700W
Input VoltageAC220V 50/60HZ or AC110V 50/60HZ (model dependent)
Temperature Range100°C - 500°C (212°F - 932°F)
Air Volume Range20 - 100 levels
Dimensions (L x D x H)175mm x 245mm x 175mm
Weight1.65kg

8. User Tips

Based on user feedback, here are some tips for getting the most out of your AIFEN-868D Hot Air Rework Station:

  • The station heats up very fast and cools down automatically in sleep mode when the hot air gun is placed in its holster, making it efficient for quick tasks.
  • The buttons for controlling temperature and air volume are intuitive and easy to use, allowing for precise adjustments.
  • Many users find the station to be well-calibrated directly from the factory, providing accurate temperature control out of the box.
  • It is highly effective for personal use and hobbyist electronics repair, such as replacing game controller sticks or other SMD components.
  • Consider using the appropriate nozzle type (cyclone for wider heating, straight for focused work) and size for optimal results.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's terms or contact the point of purchase. Keep your purchase receipt as proof of purchase.

A detailed user manual is also available in PDF format for download: AIFEN-868D User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.