KONLEN KL-T2-T Tuya WIFI Temperature Controller

User Instruction Manual

1. Introduction

The KONLEN KL-T2-T is a WIFI digital temperature controller designed for precise temperature monitoring and control. It supports both heating and cooling applications and can be managed via the Tuya Smart App or manual buttons. Key features include real-time temperature display, remote control, programmable temperature limits, and alarm notifications for out-of-range temperatures.

This controller is suitable for a wide range of commercial and industrial applications, including HVAC systems, thermal processes, boilers, breeding, aquaculture, incubation, and intelligent electromechanical equipment.

KONLEN KL-T2-T Temperature Controller

Front view of the KONLEN temperature controller with its sensor.

Application scenarios for KONLEN temperature controller

Illustrates various application scenarios for the controller, including wine cellars, chicken farms, and exhaust fan control, based on temperature thresholds.

2. Main Features

  • Real-Time Supervision: Controller and App display real-time temperature simultaneously.
  • Remote Control: Start/stop heating or cooling equipment remotely via the App.
  • Preset Working Modes: Automatically turn equipment on/off based on preset temperature values for heating or cooling.
  • Temperature Alarms: Set upper and lower temperature limits with real-time push notifications to your smartphone.
  • Offline Manual Operation: Buttons A and B allow manual ON/OFF control and setting of auto-start/stop temperatures even when WIFI is offline. Alarm notifications require an active network connection.
  • Time Period Control: Supports up to 9 groups of time period temperature control for energy saving and consumption reduction.
  • History Record: View device status and historical temperature curve charts from the App log.
  • Compact Installation: Designed to fit most power meter boxes or waterproof enclosures.

3. Specifications

Feature Specification
Product Size 91mm × 36mm × 59mm
Installation Standard 35mm mounting rail
Power Supply (Version A) AC90V to 250V
Power Supply (Version B) DC5V
Temperature Sensor Cable Length 2 meters
Detecting Temperature Range -40°C to +140°C
Measurement Error ±1°C
Output 1 relay output (Normal Open or Normal Closed)
Relay Lifespan Approx. 100,000 times ON/OFF
Contact Current Capacity 10A (resistive load 2000W), 2A (inductive load 400W motor/water pump)
Working Environment Temperature -10°C to 50°C
Package Dimensions (L x W x H) 13cm x 9cm x 8cm
Package Weight 0.186 kg

Important Note: For larger loads, an AC contactor must be added to prevent damage.

4. Setup

4.1. Physical Installation

The device is designed for installation on a standard 35mm mounting rail. It can be installed in a power meter box or a waterproof box. The temperature sensor with its 2-meter cable is waterproof and suitable for indoor and outdoor detection. However, the controller itself is NOT waterproof and must be located indoors.

KONLEN controller with sensor cable

Product with 2-meter sensor cable, showing power supply details.

Multiple KONLEN controllers in an electrical panel

Multiple KONLEN temperature controllers installed side-by-side in an electrical panel.

KONLEN controller in a protective box

A KONLEN temperature controller installed within a protective, transparent blue electrical box.

4.2. Wiring Diagram

Refer to the diagram below for correct wiring connections. Ensure all connections are secure before powering on the device.

Wiring diagram for KONLEN temperature controller

Detailed wiring diagram for the KONLEN temperature controller.

  • Terminals 1, 2, 3 (Relay Output): This is a switch output with no voltage.
    • 1 & 2: Normally Closed (N.C)
    • 2 & 3: Normally Open (N.O)
    • 2: Common (COM)
  • Terminals 4, 5 (Working Power Input): Connect your power supply here. Version A: AC90V to 250V; Version B: DC5V.
  • Terminals 6, 7 (Temperature Sensor): Connect the temperature sensor here. There is no distinction between positive and negative terminals.
  • Terminals 8, 9: Not used.

5. Operating Instructions

5.1. App Installation

  1. Download the Tuya Smart App from Google Play Store (for Android) or Apple App Store (for iOS).
  2. Install the Tuya Smart App on your smartphone.
  3. Register a new account using your email address.

5.2. WIFI Configuration (App Device Addition)

  1. Before adding the temperature controller, ensure Bluetooth is enabled on your phone.
  2. Open the Tuya Smart App and tap the "Add Device" (+) option. The app will automatically search for nearby devices. If the device is not found, press and hold the left button (CONFIG) on the controller for 3-5 seconds until the display shows "---", indicating it has entered WIFI configuration mode.
  3. Follow the in-app prompts to add the device and configure WIFI. Note: The device only supports 2.4G WIFI, not 5G WIFI. Most 5G routers also include 2.4G; switch to the 2.4G network for connection.
  4. Wait approximately 15 to 50 seconds for the configuration to complete.
Tuya App Wi-Fi network selection

App screenshot illustrating the step to select a 2.4 GHz Wi-Fi network and enter the password during device configuration.

Tuya App device added successfully

App screenshot confirming "Device added successfully" after Wi-Fi configuration.

5.3. App Instruction Overview

The KONLEN Temp Control app interface provides comprehensive control and monitoring:

KONLEN Temp Control App Interface

Screenshot of the KONLEN Temp Control app interface, highlighting various settings and real-time data display.

  1. Device Name: Can be edited.
  2. Real-Time Temperature: Displays the current temperature.
  3. Work Mode: Indicates heating or cooling mode.
  4. Sensor Status: Shows the status of the temperature sensor.
  5. Control Relay Switch ON/OFF: Manually turn the relay on or off. Note: This is only effective when the current temperature is between the preset start and stop temperature values.
  6. Alarm ON/OFF: Enable or disable the alarm function for upper/lower temperature limits.
  7. Log: Access status records and historical temperature curve charts. App History Record

    The "History Record" feature within the app, displaying relay ON/OFF status, alarm messages, and a historical temperature curve chart.

  8. Set Start-Temperature: Define the temperature at which the equipment should start.
  9. Set Stop-Temperature: Define the temperature at which the equipment should stop.
  10. Set Alarm Temperature (Lower Limit): Configure the minimum temperature for alarm notification.
  11. Set Alarm Temperature (Upper Limit): Configure the maximum temperature for alarm notification.
  12. Temperature Calibration: Adjust the temperature reading for accuracy.
  13. Relay Output Delay: Set a time delay for the relay to start.
  14. Set Control Time Period: Configure specific time schedules for temperature control.
  15. Set Temperature Control Schedule: Manage multiple time-based control schedules.

5.4. Preset Heating or Cooling Working Mode

  • Cooling Mode: Activated when the preset start temperature is higher than the stop temperature. For example, if the temperature is ≥25°C, cooling equipment starts; if ≤10°C, it stops.
  • Heating Mode: Activated when the preset start temperature is lower than the stop temperature. For example, if the temperature is ≤5°C, heating equipment starts; if >20°C, it stops.

5.5. Set Upper and Lower Limit Value of Temperature Alarm

You can set a temperature range (e.g., 12.5°C to 37.9°C). If the temperature falls outside this range, the controller will send a push alarm notification to your smartphone via the App.

TuyaSmart High/Low Temperature Alarm

Depicts the temperature alarm feature, showing notifications for high and low temperature limits via the TuyaSmart app.

Notes:

  1. Ensure App notification authority is enabled in your phone's settings (App > Me > Settings > App Notification).
  2. To enable the alarm function, light up the alarm icon in the App's main interface. To disable alarm messages, click the alarm icon again.

5.6. Time-Period Control

After setting the work mode (cooling or heating), you can add up to 9 groups of time periods for control. Settings are only active during their specified time periods, optimizing energy saving and consumption. For example, in cooling mode with a start temperature of 30°C and stop temperature of 15°C, if you set control periods from 8:00-10:00 and 16:00-18:00, the refrigeration equipment will automatically manage temperature within these times. Outside these periods, manual relay control is possible.

5.7. Manual Control Temperature Controller

  1. Press the right button for 2 seconds to enter temperature value setting. The digital display will show P00 or P01. P00 is for start temperature, P01 is for stop temperature.
  2. Continue to press the right button for 2 seconds to select either P00 or P01.
  3. Short press the left button to increase the set value; short press the right button to decrease the set value. Long pressing these buttons allows for fast adjustment.

Tip: If no button is operated within 2 seconds, the device will return to the temperature value display.

Note: In normal working mode, long press the right button to enter start/stop temperature setting. After setting the start temperature, wait 2 seconds to return to selection mode, then select and set the stop temperature. While these two parameters can be set via the App, other functions like time period and alarm can only be configured through the App.

6. User Tips

  • Many users find this controller excellent for underfloor heating systems and remote boiler operation due to its reliable temperature control and Wi-Fi capabilities.
  • The setup process, especially connecting to the Tuya Smart App, is generally straightforward and easy to configure.
  • The alarm and Wi-Fi functions are highly praised for their effectiveness and ease of connection.
  • While the sensor cable is waterproof, remember that the main controller unit is not. Always install the controller indoors or within a suitable waterproof enclosure.
  • The temperature display on the device and in the app is in Celsius.
  • The sensor type is likely NTC 10 kOhm, though not explicitly stated in the manual.

7. Maintenance

To ensure optimal performance and longevity of your KONLEN KL-T2-T temperature controller, follow these general maintenance guidelines:

  • Cleaning: Periodically wipe the device with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Environment: Ensure the controller is kept within its specified working environment temperature range (-10°C to 50°C) and away from direct moisture, excessive dust, or corrosive substances.
  • Connections: Regularly check all wiring connections for tightness and signs of wear or corrosion.
  • Sensor Care: While the sensor is waterproof, avoid physical damage to the cable or probe.
  • Software Updates: Keep the Tuya Smart App updated to the latest version to benefit from new features and bug fixes.

8. Troubleshooting

  • Device not found during App setup: Ensure Bluetooth is enabled on your phone. If still not found, press and hold the CONFIG button on the device for 3-5 seconds until "---" appears on the display to enter Wi-Fi configuration mode.
  • Cannot connect to Wi-Fi: Verify that your Wi-Fi network is 2.4GHz. The device does not support 5GHz networks. Most modern routers support both; ensure your phone is connected to the 2.4GHz band during setup.
  • No alarm notifications: Check your phone's settings to ensure notification permissions are granted for the Tuya Smart App. Also, confirm that the alarm function is enabled within the app (alarm icon is lit).
  • Temperature readings seem inaccurate: Use the temperature calibration feature in the App (point 12 in App Instruction Overview) to adjust the reading if necessary.
  • Equipment not turning on/off as expected:
    • Verify the preset start and stop temperatures are correctly configured for heating or cooling mode.
    • Check if the current temperature is within the range where manual control is effective (for manual relay switch).
    • If using time-period control, ensure the current time falls within an active schedule.
    • Inspect wiring connections for the relay output to ensure they are secure and correct.
  • Device display shows no power: Check the power input connections (Terminals 4, 5) and ensure the power supply matches the device version (AC90V-250V for Version A, DC5V for Version B).
  • Sensor not detecting temperature: Ensure the temperature sensor is correctly connected to Terminals 6, 7.

9. Warranty & Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.

An additional user manual in PDF format is available for download: View User Manual (PDF).