keepLiNK KP-9000-9XHP-X

Contents

KeepLiNK 9-Port Multi-Gigabit PoE Switch User Manual

Model: KP-9000-9XHP-X

Brand: keepLiNK

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your KeepLiNK Multi-Gigabit PoE Switch. Please read this manual thoroughly before using the device to ensure proper setup and functionality. The product is designed for multi-gigabit performance, offering 8-PoE 2.5Gb Ethernet ports and 1-SFP+ 10Gb Uplink, making it suitable for various network needs including WiFi 6 access points, security cameras, and NAS devices.

KeepLiNK Multi-Gigabit PoE Switch KP-9000-9XHP-X
Figure 1: KeepLiNK Multi-Gigabit PoE Switch (Model KP-9000-9XHP-X) with 8-2.5Gb PoE and 1-10Gb SFP+ ports. Features include Plug & Play, Fan-less design, and Built to Last construction.

2. Packing List

Please check the contents of your package against the following list. If any items are missing or damaged, please contact your vendor.

  • Device (KeepLiNK Multi-Gigabit PoE Switch)
  • AC power cord (for built-in power supply device)
  • Power adapter (for non-built-in power devices)
  • Hanging ears, screws (for rack mounted device)
  • User manual
  • Certificate of conformity

3. Setup and Installation

3.1 Installation Precautions

Adhering to these precautions will help ensure the safe and reliable operation of your switch.

Network Cable Selection

  • For 100Mbps RJ45 interfaces, use Cat5 or above Ethernet cable.
  • For 1000Mbps/2.5GE/5GE RJ45 interfaces, use Cat5e or above Ethernet cables.
  • For 10GE RJ45 interfaces, use Cat6a or above Ethernet cables.

Fiber Optic Cable Precautions

  • Fiber optics and connectors must be used in conjunction with compatible optical modules.
  • The bending radius of the optical fiber should not be less than 40mm.

Safety Precautions for Equipment Installation

  • Always ensure the power is OFF during installation.
  • Verify that the power supply voltage matches the switch's requirements.
  • Before powering on, confirm the power circuit is not overloaded.
  • To avoid electric shock, do not open the casing of the switch while it is in operation, or attempt repairs yourself.

Precautions for Equipment Installation Environment

  • Maintain appropriate temperature and humidity to ensure long-term stable operation and extend service life.
  • Regularly remove dust, maintain clean indoor air, and ensure proper grounding to prevent static electricity.
  • Keep the switch away from high-frequency, high-power, and high-current equipment to minimize electromagnetic interference.
  • For lightning protection, ensure good contact between the rack, power sockets, and ground. Use signal lightning protectors for outdoor wiring.

3.2 Switch Installation

The switch supports desktop, rack, and wall-mounted installations. Choose the method suitable for your environment.

Rack Mounted Installation

  1. Attach the provided hanging ears to both ends of the device using screws.
  2. Slide the device parallel to the tray into the cabinet.
  3. Secure the device with cabinet screws.
Rack Mount Installation Diagram
Figure 2: Diagram illustrating the process of installing the switch into a rack using hanging ears and screws.

Desktop Installation

  • Place the switch on a flat, secure desktop.
  • Ensure adequate ventilation and heat dissipation space around the switch.
  • Do not place heavy objects on top of the switch.

Wall Mounting Installation

  1. Fix screws on the wall according to the position of the wall mounting holes on the switch. Ensure a distance of 3mm ± 0.5mm between the nuts and the wall.
  2. Align the wall mounting holes on the device with the screws for installation and fixation.
Wall Mount Installation Diagram
Figure 3: Diagram showing the steps for wall mounting: punching holes, embedding nails, and mounting the switch.

4. Operating Instructions

4.1 Product Indicator Lights

The switch features various indicator lights to provide real-time status information. Refer to the table below for their definitions.

Sign Definition Status Description
PWR/P Power indicator light Green light always on Power is connected
Green light off Power is not connected
AI POE AI light Green light on AI POE started
Green light off AI POE not started
SYS/NMS/S/N System light Green light on System working
Green light off System not started
100Mbps copper port Connection status indicator light Left light (Speed) Yellow light always on 100M speed
Yellow light off 10M speed
Right light (Link/act) Green light always on Port connected
Green light off Port not connected
Green light blink Port connected and data transmission/reception
(Specific indicator lights are subject to the actual product)
1000Mbps copper port Connection status indicator light Left light (Speed) Yellow light always on 1000M speed
Yellow light off 10/100M speed
Right light (Link/act) Green light always on Port connected
Green light off Port not connected
Green light blink Port connected and data transmission/reception
(Specific indicator lights are subject to the actual product)
2.5G copper port Connection status indicator light Left light (Speed) Yellow light on 2.5G speed
Yellow light off or green light always on 10/100/1000M speed
Right light (Link/act) Green light always on Port connected or 10/100/1000M speed
Green light off Port not connected
Light blink Port connected and data transmission/reception
(Specific indicator lights are subject to the actual product)
10G copper port Connection status indicator light Left light (Speed) Yellow light on 10G speed
Green light on 5G speed
Right light (Link/act) Light blink Data transmission and reception
Yellow light on 2.5G rate
Green light on 1G rate
Light off Port not connected
10G downlink fiber port Connection status indicator light Link/act Yellow light always on 10G speed
Green light always on 1G rate
Light off Port not connected
Light blink Port connected and data transmission/reception
(Specific indicator lights are subject to the actual product)
Optical port connection status indicator light Link/act Green light on Port connected
Green light off Port not connected

4.2 DIP Switch Settings

The DIP switches allow for configuration of various functions. The specific definitions may vary based on the product version (Non-PoE, PoE, or Lite Management). Always refer to the actual product for precise settings.

DIP Switch Definition for Non-PoE Switch

DIP switch specification Sequence Definition of DIP switch Description
4 DIP Switch 1 Reserve Reserve
2 Extend 250m long distance transmission (downlink port)
3 Port Isolation Port isolation
4 Storm Control Suppress broadcast data

DIP Switch Definition for PoE Switch

DIP switch specification Sequence Definition of DIP switch Description
4 DIP Switch 1 AI POE Auto detect and reboot unresponsive PoE devices for recovery
2 Extend 250m long distance transmission (PoE port)
3 Port Isolation Port isolation
4 Storm Control Suppress broadcast data
3 DIP Switch 1 Extend 250m long distance transmission (PoE port)
2 Standard Normal mode
3 Port Isolation Port isolation
2 DIP Switch 1 Extend 250m long distance transmission (PoE port)
2 AI PoE/Reserve AI PoE/Reserve

DIP Switch Definition for Lite Management Switches

DIP switch specification Sequence Definition of DIP switch Description
3 DIP Switch 1 Web-managed WEB management
2 Standard Normal mode
3 Port Control Port isolation

4.3 PoE Powered Function

This feature is applicable to PoE switches. The standard PoE power supply includes protocol detection, power pin sequence detection, power output, anomaly protection, and link anomaly monitoring.

  • PoE protocols supported: IEEE802.3af (15.4W), IEEE802.3at (30W), and IEEE802.3bt (90W).
  • Standard PoE power supply pin sequence: 1,2+/3,6-.
  • Standard PoE++ power supply pin sequence: 1,2,4,5+/3,6,7,8-.
  • Standard PoE switches automatically detect and provide power to standard PoE devices. Non-PoE devices will not be powered on and will only transmit data.
Key Features and PoE Power Supply Diagram
Figure 4: Key features of the switch, including 8x 1G/2.5G Ethernet Ports, 8x PoE+ Ports, 1x 1G/10G SFP+ Port, silent operation, and desktop or wall mount options. The rear panel shows the AC input.

4.4 Web Management (for Lite Management Models)

This section applies only to models with Lite Management capabilities. For first-time use:

  1. Connect the device to a PC and ensure the device initialization is complete.
  2. Configure the PC's IP address to be in the same network segment as the switch's default IP address.
  3. Open a PC browser and input "http://192.168.1.168". Press "Enter" to access the network management login interface.
  4. Enter the default username "admin" and password "admin" to log in.
Web Management Login Screen
Figure 5: Example of a web management login screen, showing fields for Username, Password, and Language selection.

4.5 Console Port Management

For advanced configuration, you can use the console port:

  1. Connect a console port cable between your PC and the switch's console port.
  2. Open terminal simulation software on your PC.
  3. Establish a connection, select the serial port, and configure communication parameters:
    • Transmission rate: 115200
    • Data bit: 8
    • Check digit: None
    • Stop bit: 1
    • Flow control method: None

5. Maintenance

To ensure the longevity and optimal performance of your KeepLiNK switch, follow these maintenance guidelines:

  • Environmental Control: Maintain the switch in an environment with stable temperature and humidity as specified in the installation precautions.
  • Cleaning: Regularly clean the device to prevent dust accumulation, which can affect performance and lead to overheating. Use a soft, dry cloth.
  • Ventilation: Ensure that the ventilation openings are clear and unobstructed to allow for proper airflow and heat dissipation. The fan-less design relies on passive cooling.
  • Cable Management: Keep network and power cables organized to prevent accidental disconnections or damage.
  • Firmware Updates: Periodically check the manufacturer's website for any available firmware updates. Follow the provided instructions carefully for any update procedures.

6. Troubleshooting

This section provides solutions to common issues you might encounter with your switch.

6.1 General Network Issues

  • No Power: Check the power cord connection and ensure the power outlet is functional. Verify the PWR/P indicator light is on.
  • No Link/Activity:
    • Ensure network cables are securely connected to both the switch and the connected device.
    • Verify the correct cable type is used for the port speed (e.g., Cat5e for Gigabit).
    • Check the Link/Act indicator light for the specific port. If off, the port is not connected. If blinking, there is data transmission.
    • Test with a different cable or port.
  • Slow Network Speed:
    • Check the speed indicator light (Left light) for the port to confirm the negotiated speed (e.g., Yellow for 2.5G, Green for 5G, Yellow for 10G).
    • Ensure connected devices support the desired multi-gigabit speeds.
    • Verify cable quality and length meet specifications for higher speeds.

6.2 PoE Device Issues

  • PoE Device Not Powering On:
    • Ensure the connected device is PoE-compatible (IEEE802.3af/at/bt).
    • Check the AI POE indicator light. If off, AI POE is not started.
    • If using a PoE switch with AI PoE function, ensure the DIP switch for AI PoE is enabled (if applicable). This feature can auto-detect and reboot unresponsive PoE devices.
    • Verify the total PoE power budget of the switch is not exceeded by all connected devices.
  • Unresponsive PoE Devices: If a PoE device becomes unresponsive, the AI PoE function (if enabled via DIP switch) can automatically detect and reboot it for recovery.

6.3 Management Access Issues (for Lite Management Models)

  • Cannot Access Web Interface:
    • Ensure your PC's IP address is in the same subnet as the switch's default IP (e.g., 192.168.1.x).
    • Verify the correct IP address (http://192.168.1.168) is entered in the browser.
    • Confirm the DIP switch for "Web-managed" is set correctly (if applicable).
    • Try clearing browser cache or using a different browser.
  • Incorrect Login Credentials: The default username and password are "admin" and "admin". If changed and forgotten, a factory reset might be required (refer to advanced documentation or support).

7. Specifications

Below are the technical specifications for the KeepLiNK KP-9000-9XHP-X Multi-Gigabit PoE Switch.

Feature Specification
Brand NamekeepLiNK
Model NumberKP-9000-9XHP-X
Switch TypeGigabit Switch
Number of Interfaces9 (8-PoE and 1-SFP+)
Ethernet Interfaces8-PoE and 1-SFP+
FunctionPOE, VLAN Support
VLANYes
Transmission Rate10000 Mbps (10Gbps SFP+ uplink)
Switch Capacity60Gbps
Communication ModeFull-Duplex & Half-Duplex
CertificationCE, FCC, RoHS
Input voltageAC100-240V/50-60Hz
Standby Power10W
PoE Port1-8
PoE ProtocolIEEE802.3af/at
PoE Power Budget135W
PoE Pinout1,2,3,6
Max Power each port30W
Packet forwarding rate44.64Mpps
MAC address table4K
Buffer8.1Mbit
Forwarding delay<10us
MDX/MDIXYes
Jumbo Frame16Kbytes
Operating temperature-10℃~+50℃
Storage temperature-40℃~+70℃
Thermal methodsFan-less
Dimension190 x 140 x 44 mm
Installation MethodDesktop or wall mount
Weight0.8 kg
Front view of KeepLiNK Multi-Gigabit PoE Switch
Figure 6: Front view of the KeepLiNK Multi-Gigabit PoE Switch, showing the 2.5G Ethernet ports and the 10G SFP+ port.

8. User Tips

Based on user experiences, here are some helpful tips for getting the most out of your KeepLiNK switch:

  • Quiet Operation: Many users appreciate the fan-less design, noting its very quiet operation, making it suitable for home or office environments where noise is a concern.
  • Excellent for PoE Devices: The switch is highly recommended for powering PoE surveillance cameras, IoT devices, and WiFi access points (like Unifi APs) without issues.
  • Speed Boost: Users have reported significant increases in home network speeds, reaching 2.5Gbit and improving data transfer rates.
  • Plug-and-Play: For basic network expansion, the switch is largely plug-and-play, requiring no complex configuration.
  • Managed Features: While primarily unmanaged for basic use, the "Lite Management" models offer web-based configuration for advanced settings like VLANs, which can be accessed via a browser.
  • Physical Size: Be aware that the physical dimensions might be slightly thicker than some western counterparts, which could be a factor for tight installations.
Multi-Gigabit Performance Diagram
Figure 7: Diagram illustrating the multi-gigabit performance of the switch, connecting various devices like WiFi 6 Access Points, Security Cameras, 2.5G NAS, and IP Phones.
Unmanaged Switches are Plug-and-Play Diagram
Figure 8: Diagram emphasizing the plug-and-play nature of unmanaged switches, showing direct connections to devices like WiFi Access Points, IP Cameras, Computers, and Ready NAS without complex setup.

9. Warranty and Support

9.1 After-sales Service Letter of Commitment

Within seven days from the date of sale, if the entire device fails, you may choose to repair, replace, or return it. If a performance failure occurs within seven days to one year from the date of sale (based on the purchase invoice and proof of three guarantees), the machine can be repaired or replaced.

Beyond the one-year hardware warranty period, the cost of replacing hardware will be borne by the user, and no additional costs will be added by our company.

9.2 Other Service Commitments

We provide 7x24 hour after-sales support services.

9.3 Circumstances Without Warranty Coverage

Failure or damage of equipment (including parts) under the following circumstances are not covered by warranty:

  • Accessories supplied by other companies (e.g., power supply, adapter) are guaranteed by their respective manufacturers.
  • The entire machine and parts have exceeded the warranty period.
  • Equipment failure or damage not caused by repair, alteration, or demolition by personnel from our company.
  • Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, or inputting inappropriate voltage.
  • Failure or damage caused by the use of non-genuine or unpublished software.
  • Failures or losses caused by natural disasters, such as force majeure (e.g., earthquakes and fires).

9.4 Warranty Card Information

A warranty card is included with the product. Please retain your purchase invoice and fill in the following details for warranty purposes:

  • User name
  • User address
  • Post code
  • Contact address
  • Contact person
  • Tel
  • E-mail
  • Product model number
  • Serial number
  • Date of purchase

For a complete digital version of this user manual, you can refer to the PDF document: User Manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.