GRN-FLASHING LM02A

Contents

LED Module Light User Manual

Model: LM02A (SMD 5050) | Brand: GRN-FLASHING

1. Introduction

This manual provides detailed instructions for the safe and effective installation, operation, and maintenance of your GRN-FLASHING LM02A LED Module Lights. These modules are designed for various applications, including shop advertising, decorative lighting, signboards, and letter light-boxes.

Overview of GRN-FLASHING LED modules showing various colors and individual module design
Figure 1: GRN-FLASHING LED Module Lights in various colors.

2. Safety & Warnings

Important Safety Information: Read all instructions before use. Failure to follow these instructions may result in damage to the product or personal injury.

  • Keep the device and its cord out of reach of children under 3 years old.
  • Keep away from children unless supervised by an adult.
  • Do not use this product for purposes other than its intended use.
  • Inspect the product before each use; do not use if damaged.
  • Follow installation and operation guidelines to avoid injury.
  • Do not expose to water or moisture.

3. Product Information

3.1 Manufacturer & EU Representative

Detail Manufacturer EU Authorized Representative
Name Shenzhen Lvseshuxing Technology Co., LTD GAVIMOSA CONSULTORIA, SOCIEDAD LIMITADA
Address 708, Floor 7, Unit 2, Building B, Xinglongfu Chuangke Park, Yousong Road, Yousong Community, Longhua Street, Longhua District, Shenzhen, 518110 CASTELLANA 9144, 28046 Madrid
Contact Person YiQi Wen Jorge Wilson
Tel 18820779209 +34 696313170
E-mail 52680771@qq.com compliance.gavimosa@outlook.com

3.2 Compliance Information

The object of the declaration described above is in conformity with the relevant Union harmonization legislation.

Directives Standard/Specification
CE-RED 2014/53/EU EN IEC 62311:2020
EN IEC 60598-2-1:2021 used in conjunction with EN IEC 60598-1:2021 + AMD11:2022
ETSI EN 301 489-1 V2.2.3 (2019-11)
ETSI EN 301 489-17 V3.2.4 (2020-09)
ETSI EN 300 328 V2.2.2 (2019-07)
CE-RoHS 2011/65/EU EN IEC 63000:2018

4. Setup & Installation

Follow these steps for proper installation of your LED module lights:

  1. Check Voltage: Before connecting, verify that the voltage of your LED module light bar matches the output voltage of your DC power supply. These modules operate on DC 12V.
  2. Power Supply Connection: Connect the LED modules to a compatible DC power supply. The red wire of the LED module is the positive electrode (V+), and the black wire is the negative electrode (V-). Ensure correct polarity to prevent damage.
  3. Controller Integration (Optional for RGB/Dimmable): If using RGB or dimmable modules, connect a suitable controller between the DC power adapter and the LED lights. Refer to the controller's manual for specific connection details.
  4. Surface Preparation: Ensure the surface where you intend to install the LED modules is clean, dry, and smooth.
  5. Adhesive Application: Carefully tear off the protective film from the adhesive tape on the back of each LED module.
  6. Mounting: Firmly press the LED module onto the desired surface. Ensure good contact for optimal adhesion.
Close-up of several LED modules, highlighting the wiring and construction
Figure 2: Close-up view of LED modules and their wiring.

4.1 Wiring Diagram

The following diagram illustrates a typical installation schematic:

Figure 3: Installation Schematic for LED Module Lights.

5. Operation

Once properly installed and powered, your LED module lights are ready for use.

  • Power On/Off: The lights will illuminate once power is supplied to the DC power adapter. To turn them off, disconnect the power or use a switch if one is integrated into your setup.
  • Color Control (for RGB modules): If you have RGB modules and a compatible controller, use the controller to select desired colors, adjust brightness, or choose dynamic lighting modes.
Video 1: Demonstration of LED module color changing capabilities.

The LED modules are available in various single colors and RGB options:

RGB LED modules with multi-colored wiring
RGB Modules
Blue LED modules illuminated
Blue Modules
Warm white LED modules illuminated
Warm White Modules
Green LED modules illuminated
Green Modules

6. Maintenance

To ensure the longevity and optimal performance of your LED module lights, follow these maintenance guidelines:

  • Cleaning: Gently wipe the surface of the LED modules with a soft, dry cloth. For stubborn dirt, a slightly damp cloth can be used, but ensure no moisture enters the module housing. Do not use harsh chemicals or abrasive cleaners.
  • Inspection: Periodically check the wiring for any signs of wear, fraying, or loose connections. Ensure the adhesive remains secure.
  • Environmental Conditions: While rated IP65 waterproof, avoid prolonged exposure to extreme weather conditions or submersion in water. The working environment temperature range is -40°C to +80°C.

7. Troubleshooting

If you encounter issues with your LED module lights, refer to the following common problems and solutions:

Problem Possible Cause Solution
Lights do not turn on
  • No power supply
  • Incorrect wiring polarity
  • Faulty power adapter/controller
  • Damaged module
  • Check power source and connections.
  • Verify red wire to V+ and black wire to V-.
  • Test power adapter/controller with another device or replace.
  • Inspect modules for visible damage; replace if necessary.
Lights flicker or dim
  • Loose connection
  • Insufficient power supply
  • Overloaded circuit (too many modules)
  • Check all wiring connections for tightness.
  • Ensure power supply meets total wattage requirements.
  • Reduce the number of modules or use a more powerful power supply/amplifier.
Colors are incorrect (RGB)
  • Controller malfunction
  • Incorrect controller settings
  • Check controller connections and settings.
  • Refer to controller manual for proper configuration.

8. Specifications

Feature Detail
Product NameLED Module Light
Model NumberLM02A
Brand NameGRN-FLASHING
Item TypeLED Modules
LED TypeSMD 5050
LED Quantity (per module)5 pcs
VoltageDC 12V
Power SourceDC
Luminous Flux60-249
Emitting ColorWhite/Red/Warm White/Blue/Green/Yellow/RGB
View Angle120°
Waterproof IP GradationIP65
MaterialPVC
Length75mm
Width12mm
Height5mm
Working Environment-40°C to +80°C
CertificationRoHS, CE
Warranty1 year
Package Includes20pcs LED Modules

9. User Tips

  • For outdoor applications, ensure all connections are properly sealed and protected from direct water exposure, despite the IP65 rating, to maximize lifespan.
  • When planning your installation, consider the total power draw of all modules to select an appropriately sized power supply and, if needed, LED amplifiers to prevent voltage drop and ensure uniform brightness.
  • Test the modules and connections before final mounting to easily identify and resolve any issues.

10. Warranty & Support

This product comes with a 1-year warranty from the date of purchase. For technical support, warranty claims, or any inquiries, please contact the manufacturer or EU authorized representative using the contact information provided in Section 3.1 of this manual.

A detailed user manual in PDF format is also available for download. You can find it by searching for the product model LM02A on the manufacturer's support page or by referencing the original product listing.

© 2024 GRN-FLASHING. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.