1. Introduction
The NJTY T21L is a multi-purpose instrument designed for high measurement accuracy, fast response speed, and a high safety level. It features a special chip with up to 6000 counts, composed of high-precision AD and a high-speed digital processor. This design ensures accurate measurements, high resolution, fast calculation speed, and high-speed true effective value calculation of AC 1KHz. The device is software calibrated, maintaining accuracy over long-term use.
Its aesthetic design makes it suitable for various industrial applications, with a safe and reliable circuit. The multimeter offers numerous measurement functions and a user-friendly interface, catering to professional engineers and maintenance personnel. It can measure DC and AC voltage, DC and AC current, resistance, capacitance, inductance, temperature, diode, and perform circuit continuity testing.
For convenience in dark environments, this instrument is equipped with a backlight and an illumination lamp.
2. Safety Information
Safety Instructions
When using this meter, the user must comply with all standard safety regulations concerning:
- Protection against electric shocks.
- Preventing the misuse of the instrument's safety procedures.
To ensure personal safety, always use the provided test probes, check them before use, and ensure they are intact.
Safety Signs
| Symbol | Description |
|---|---|
| ▲ | Warning |
| ~ | AC (alternative current) |
| --- | DC (direct current) |
| ⏚ | Ground |
| ☐ | Double insulation |
| CE | European Union standard |
| ⚡ | High voltage warning |
| CAT II | Category overvoltage protection |
Precautions for Use
- The meter may become unstable or show large errors near devices with strong electromagnetic interference.
- Do not use the meter if its appearance or the test probes are damaged.
- Incorrect use may compromise the meter's safety functions.
- Exercise caution when working near bare conductors or busbars.
- Do not use this instrument near explosive gas, vapor, or dust.
- Always use the correct input function for the selected measurement range.
- Do not switch gears while measuring voltage or current.
- The input value must not exceed the specified limit for each range to prevent damage.
- Do not touch unused input terminals when the instrument is connected to a circuit under test.
- Use caution to prevent electric shock when measuring voltages exceeding 60 VDC or 30 VAC.
- When measuring with test probes, place your finger behind the guard ring.
- Before changing the range, ensure the test probes are disconnected from the circuit.
- Before measuring resistance, diode, capacitance, or performing a continuity test, ensure the circuit under test is powered off and all high-voltage capacitors are discharged.
- Do not measure resistance on a live circuit or perform a buzzer test on a live circuit.
- Before current measurement, check the meter's fuse.
- Before connecting the meter to a circuit for current measurement, turn off the circuit's power.
- When repairing TVs or measuring power conversion circuits, be aware of high-amplitude voltage pulses to avoid damaging the meter.
Input Protection Measures
- The limit voltage for voltage measurement is 600V.
- The limit voltage for capacitance or diode measurement is 250 ACV or its equivalent RMS voltage.
- When measuring μA and mA current, the meter is protected by a 600mA/250V fuse.
3. Panel Diagram
- Illumination
- NCV sensing area
- LED display
- Buzzer
- Backlight/illumination button
- "FUNC/Hz" selection button
- Gear rotary switch
- Hz/VΩMAL C input socket
- COM input socket
- 10A input socket
- HOLD key
- NCV indicator
4. Monitor Symbols Explanation
| Symbol | Description |
|---|---|
| Battery low voltage display | |
| Auto power off | |
| - | Negative polarity input indication |
| AC | Alternative input indication |
| DC | Direct input indication |
| ))) | In continuity test mode |
| →|← | In diode test mode |
| L | Inductance measurement |
| AUTO | Auto ranging mode |
| H | Data hold mode |
| °C, °F | Temperature |
| % | Duty cycle |
| NCV | Non-contact voltage detection mode |
| V, mV | Volt, unit of Voltage |
| A, mA, μA | Ampere, unit of current |
| Ω, KΩ, MΩ | Ohm, unit of resistor |
| Hz, KHz, MHz | Hz, hertz, unit of frequency |
| mF, μF, nF, pF | Farah, unit of capacitance |
| H, mH, μH | Inductance unit |
5. Technical Specifications
Comprehensive Indicators
- Operating conditions: 600V CAT II, Pollution grade: 2, Height: under 2000m
- Working temperature: 0-40 °C (<80%RH)
- Storage temperature: -10-60 °C (<70%RH, remove battery)
- Test/calibrate surrounding temperature: 25 °C ±2°C
- Maximum voltage between measurement end and ground: 600V
- Fuse protection: "μA/mA" fuse 600mA/250V; "A" fuse 10A/250V
- Conversion rate: Approximately 3s/second
- Display: 6000 counts LED display
- Overload indication: 'OL' displayed
- Low voltage display: displayed when working voltage is low
- Input polarity indicator: "-" shown automatically
- Power: 3 x 1.5V AAA Batteries
- Dimensions: 147mm (L) x 71mm (W) x 45mm (H)
- Weight: Approximately 220g (battery excluded)
Accuracy Index
Accuracy: ± (%reading + digit), one year warranty from the manufacture date.
Conditions: Surrounding temperature from 18 °C to 28 °C, <80%RH.
Direct Current Voltage (DCV)
| Range | Resolution | Accuracy |
|---|---|---|
| 60mV | 0.01mV | ± (0.5%Readings + 5digits) |
| 600mV | 0.1mV | |
| 6V | 0.001V | |
| 60V | 0.01V | |
| 600V | 0.1V |
Input resistance: 10MΩ
Maximum input voltage: 600VDC
Alternative Current Voltage (TRMS)
| Range | Resolution | Accuracy |
|---|---|---|
| 60mV | 0.01mV | ± (1%Readings + 4digits) |
| 600mV | 0.1mV | |
| 6V | 0.001V | |
| 60V | 0.01V | |
| 600V | 0.1V |
Input resistance: 10MΩ
Maximum input voltage: AC600V
Frequency response: 40HZ to 1KHZ true RMS
Resistance
| Range | Resolution | Accuracy |
|---|---|---|
| 600Ω | 0.1Ω | ± (0.8%Readings + 5digits) |
| 6KΩ | 0.001KΩ | |
| 60KΩ | 0.01KΩ | |
| 600KΩ | 0.1KΩ | |
| 6MΩ | 0.001MΩ | |
| 60MΩ | 0.01MΩ |
Overload protection: 250V DC/AC
Open circuit voltage: 0.52V
Diode and Buzzer
| Function | Testing Condition | Open-circuit Voltage |
|---|---|---|
| →|← | The display shows the approximate value of the forward voltage of the diode | 3.2V |
| ))) | When the internal resistance is lower than 600Ω, the buzzer sounds and the red indicator light lights up | 1V |
Overload protection: 250V DC/AC
Direct Current
| Range | Resolution | Accuracy |
|---|---|---|
| 600μA | 0.1μA | ± (1.2%Readings + 5digits) |
| 6000μA | 1μA | |
| 60mA | 0.01mA | |
| 600mA | 0.1mA | |
| 6A | 0.001A | ± (3%Readings + 5digits) |
| 10A | 0.01A |
Overload protection: μA/mA range fuse (600mA/250V); 10A range fuse (10A/250V).
When the measurement current is greater than 10A, continuous measurement time cannot exceed 10 seconds to prevent solder joint melting. After measurement, stop current measurement for at least 1 minute before re-measuring.
Alternative Current
| Range | Resolution | Accuracy |
|---|---|---|
| 600μA | 0.1 μA | ± (1.2%Readings + 5digits) |
| 6100μA | 1μA | |
| 60mA | 0.01mA | |
| 600mA | 0.1mA | |
| 6A | 0.001A | ± (3%Readings + 5digits) |
| 10A | 0.01A |
Overload protection: μA/mA range fuse (600mA/250V); 10A range fuse (10A/250V).
Maximum input current: mA level: 600mA AC effective value; 10A level: 10A AC effective value.
When the measurement current is greater than 10A, continuous measurement time cannot exceed 10 seconds to prevent solder joint melting. After measurement, stop current measurement for at least 1 minute before re-measuring.
Frequency response: 40Hz-1KHz, true RMS.
Frequency
| Range | Resolution | Accuracy |
|---|---|---|
| 9.999Hz | 0.001Hz | ± (1.5%Readings + 5digits) |
| 99.99Hz | 0.01Hz | |
| 999.9Hz | 0.1Hz | |
| 9.999KHz | 0.001KHz | |
| 99.99KHz | 0.01KHz | |
| 999.9KHz | 0.1KHz | |
| 9.999MHz | 0.001MHz |
Input voltage range: 200mV-10V AC RMS
Overload protection: 250V DC/AC
Capacitance
| Range | Resolution | Accuracy |
|---|---|---|
| 6000pF | 1pF | ± (4.0%Readings + 5digits) |
| 60nF | 0.01nF | |
| 600nF | 0.1nF | |
| 6μF | 0.001μF | |
| 60μF | 0.01 μF | |
| 600μF | 0.1μF | |
| 6mF | 0.001mF | |
| 60mF | 0.01mF | |
| 100mF | 0.1mF |
Overload protection: 250V DC/AC
Temperature
| Range | Resolution | Temperature Range | Accuracy |
|---|---|---|---|
| °C | 1°C | -20°C ~ 1000°C | ± (1.0% + 3) Readings |
| °F | 1°F | -4°F ~ 1832°F | ± (1.0% + 3) Readings |
Overload protection: 250V DC/AC
Inductance
| Range | Resolution | Accuracy |
|---|---|---|
| 600μH | 0.1μH | ± (4.0%Readings + 5digits) |
| 6mH | 0.001mH | |
| 60mH | 0.01mH | |
| 600mH | 0.1mH | |
| 6H | 0.001H | |
| 60H | 0.01H |
Overload protection: 250V DC/AC
6. Setup
Battery Installation
The instrument uses three AAA 1.5V batteries as the power supply. The battery must be properly installed in the battery compartment.
When the low voltage symbol appears, replace the battery immediately. Insufficient battery power can lead to incorrect readings, electric shock, or personal injury.
To replace the battery:
- Turn off the power of the instrument.
- Pull all test probes out of the input sockets.
- Use a screwdriver to loosen the screws fixing the battery cover.
- Remove the battery cover.
- Remove the old batteries.
- Replace with new 3 x 1.5V AAA batteries.
- Install the battery cover and close the screws.
7. Operating Instructions
On/Off Operation
Turn the gear switch to any measurement position to turn on the multimeter. If there is no operation for about 15 minutes after powering on, the instrument will beep and enter sleep mode. Press any button or rotate the gear switch to restart.
"HOLD" Key: Data Hold Function
- During measurement, short press the HOLD key to freeze the current display value (voltage, current, resistance, capacitance, inductance). Short press again or rotate the gear switch to cancel.
- Press and hold the HOLD button to turn on the multimeter. Three beeps will indicate that the automatic shutdown function is canceled. The device will restart and restore the auto-shutdown function.
"FUNC/Hz" Key: Function Selection
- In AC/DC voltage and AC/DC current measurement modes, this button switches between current and voltage levels. When measuring AC voltage or current, long press "FUNC/Hz" to switch to frequency measurement (0~1KHz signals with voltage below 250V).
- In the resistance, capacitance, on-off, diode measurement range, short press "FUNC/Hz" to cycle through these modes.
Backlight and Lighting Functions
- Short press the key to turn on/off the backlight. If no operation for 30 seconds, the backlight turns off automatically.
- Long press the button to turn on the lighting (flashlight), and the backlight will also activate. Short press again to turn off both. If no operation for 30 seconds, both turn off automatically.
- When the backlight is on, long pressing the button for 2 seconds can also turn on the lighting. If no operation for 30 seconds, both turn off automatically.
ACV and DCV Measurement
▲ Do not measure any voltage greater than AC600V or DC600V to prevent electric shock or damage to the instrument.
- Turn the rotary switch to the "mV" or "V" position, and press "FUNC/Hz" to select DC or AC.
- Connect the black test lead to the COM input socket and the red test lead to the V input socket.
- Use the other ends of the test probes to measure the voltage of the circuit under test (connect in parallel).
- The display shows the measured voltage. For DC voltage, if the red test lead touches the negative pole, a "-" polarity symbol will be displayed.
Notice:
- In DC or AC 600mV and 6V ranges, if no test probe is connected, the meter may show some readings. Short-circuit the "V-Ω" and "COM" terminals to zero the display.
- Under AC voltage function, long press "FUNC/Hz" to measure the frequency of the AC voltage source.
- The AC voltage value measured is the true effective value (RMS). For sine waves and other waveforms (without DC offset), such as square waves, triangle waves, and step waves, these measurements are accurate.
Resistance Measurement
▲ To avoid damage, power off the circuit and discharge all high-voltage capacitors before measuring resistance.
- Turn the rotary switch to the "Ω" position and press "FUNC/Hz" to select the "Ω" range.
- Connect the black test probe to the COM input socket and the red test probe to the "V/Ω" input socket.
- Use the other ends of the test probes to measure the resistance of the circuit under test.
- The display shows the measured resistance value.
Notice:
- The measured resistance value on a circuit may differ from the resistor's rated value due to parallel resistance and capacitance.
- For accurate low resistance measurement, first short-circuit the test leads and record their resistance value. Subtract this value from subsequent measurements.
Diode Measurement
▲ To avoid damage, power off the circuit and discharge all high-voltage capacitors before measuring diodes.
- Turn the rotary switch to the "→|←" position and press "FUNC/Hz" to select the "→|←" range.
- Connect the black test lead to the COM input socket and the red test lead to the V/Ω input socket.
- Connect the black test probe to the cathode and the red test probe to the anode of the diode.
- The meter displays the forward conduction voltage value. If the test probe polarity is reversed, the meter will display "OL".
Buzzer Test (Continuity)
▲ To avoid damage, power off the circuit and discharge all high-voltage capacitors before performing a continuity test.
- Turn the rotary switch to the "Ω" position and press "FUNC/Hz" to select the "))) " range.
- Connect the black test lead to the COM input socket and the red test lead to the V/Ω input socket.
- Use the other ends of the test probes to measure the resistance of the circuit. If the resistance is less than 600Ω, the indicator light will illuminate, the buzzer will sound continuously, and the display will show the resistance value.
Capacitance Measurement
▲ To avoid damage, power off the circuit and discharge all high-voltage capacitors before measuring capacitance.
- Turn the rotary switch to the "F" position and press "FUNC/Hz" to select the "F" range.
- Connect the black test probe to the COM input socket and the red test probe to the "V/Ω" input socket.
- Touch the two terminal pins of the capacitor with the test probes. The display will show the measured capacitance value.
Notice:
- When measuring large capacitance, it may take some time for the reading to stabilize.
- When measuring polarized capacitance, pay attention to the correct polarity to avoid damaging the instrument and ensure measurement accuracy.
Frequency Measurement
▲ Do not test any voltage higher than 250V to prevent electric shock or damage to the instrument.
- Turn the rotary switch to the "Hz%" position.
- Connect the black test probe to the COM input socket and the red test probe to the "Hz" input socket.
- Use the other ends of the test probes to measure the frequency value of the circuit under test.
- Press "FUNC/Hz" to display frequency and duty cycle respectively.
Current Measurement
▲ Never attempt to measure current on a circuit where the open circuit voltage to ground exceeds 250V. If the fuse blows, the meter may be damaged or you may be injured. Always check the meter's fuse before measuring current. Short-circuit measurement of mains power supply is prohibited.
When measuring, use the correct input socket, function range, and range. When the test probe is plugged into the current input socket (μA, mA, A), do not connect the two test probes in parallel to any circuit, as this risks burning out the instrument or electric shock.
- Turn the rotary switch to the "μA", "mA", or "A" position, and press "FUNC/Hz" to select AC or DC.
- Connect the black test lead to the COM input socket. If the measured current is less than 600mA, connect the red test probe to the VΩMA input socket. If the current is between 600mA and 10A, connect the red test probe to the 10A input socket.
- Disconnect the circuit to be tested. Connect the black test lead to the lower voltage end of the disconnected circuit and the red test lead to the higher voltage end.
- Connect power to the circuit and read the display. If the display shows "OL", the input exceeds the selected range. After powering off, turn the rotary switch to a higher range.
- In ACA measurement state, long press "FUNC/Hz" to display the frequency of the AC signal 0~1KHz.
NCV Test (Non-Contact Voltage Detection)
- Rotate the rotary switch to the "NCV" position.
- Place the top of the meter (NCV sensing area) close to the conductor. If AC voltage is detected, the indicator light will illuminate based on signal strength, and the buzzer will emit different frequencies.
Notice:
- Voltage may still be present even when not indicated. Do not rely solely on non-contact voltage detectors to determine voltage presence. Detection can be affected by factors like socket design, insulation thickness, and type.
- If voltage is input to the meter's input terminal, the voltage sensor indicator light may also light up due to induced voltage.
- External interference (e.g., flashlights, motors) may mistakenly trigger non-contact voltage detection.
Temperature Measurement
- Turn the rotary switch to the "°C (°F)" position. The instrument will display the ambient temperature.
- Remove the test leads and insert the thermocouple into the "COM" and "VΩMA" input terminals, observing correct polarity.
- The meter will display the approximate temperature value transmitted from the thermocouple.
Inductance Measurement
- Turn the rotary switch to the "L" position.
- Connect the black test probe to the COM input socket and the red test probe to the "VΩMAL" input terminal.
- Touch both ends of the inductance device with the test probes. The display will show the measured inductance value.
8. Maintenance
General Maintenance
- To avoid electric shock or damage, do not get the inside of the meter wet.
- Before opening the case or battery cover, turn off the power and ensure the test probes are disconnected from the circuit.
- Clean the instrument case regularly with a damp cloth and a small amount of detergent. Do not use abrasives or chemical solvents.
- Dirty or damp input sockets can cause oxidation of metal surfaces, affecting readings.
Replacing Fuses
Only use designated fuses (600mA/250V, 10A/250V fast-blow fuses). To avoid electric shock or personal injury, turn off the multimeter before opening the battery cover to replace a new fuse. Ensure the test lead is disconnected from the circuit being measured.
To replace a fuse, follow the same steps as battery replacement (Section 6. Setup), and replace the damaged fuse with a new one (a spare fuse is typically located under the battery cover).
Long-Term Storage
If the instrument will not be used for a long time, remove the batteries to prevent leakage and damage. Store in a cool, dry place, avoiding high temperatures and humidity.
9. Troubleshooting
- "OL" Display: If the display shows "OL" during measurement, it means the measured value exceeds the current range. Switch to a higher range. If it appears during diode measurement, it indicates reversed polarity or an open circuit.
- Unstable Readings: Unstable readings can occur near devices with strong electromagnetic interference. Move away from such devices. For large capacitance measurements, allow some time for the reading to stabilize.
- Low Battery Indicator: If the battery low voltage symbol appears, replace the AAA batteries immediately to ensure accurate readings and prevent potential hazards.
- Meter Not Turning On: Ensure batteries are correctly installed and charged. If the meter entered sleep mode, press any button or rotate the gear switch to wake it up.
- Inaccurate Readings: Ensure test probes are clean and undamaged. Verify the correct measurement function and range are selected. For resistance, compensate for test lead resistance if measuring very low values.
10. User Tips
- Probe Quality: While the included probes are functional, some users recommend replacing them with higher-quality, more sensitive probes for enhanced performance, especially for precise measurements.
- Magnetic Back: Utilize the magnetic back feature to conveniently attach the multimeter to metal surfaces, freeing up your hands during work.
- Backlight Usage: The LCD display can appear dim in certain lighting conditions. Always use the backlight function for better readability, especially in darker environments.
- Inductance and Capacitance: This multimeter is highly praised for its ability to measure inductance (down to 0.1μH) and large capacitance values (up to 100mF), making it suitable for a wide range of electronic projects and repairs.
- Auto-Ranging: The auto-ranging feature simplifies operation by automatically selecting the correct measurement range, reducing the chance of errors.
11. Warranty and Support
This product comes with a one-year warranty from the manufacturing date. For technical support, service, or warranty claims, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
For additional documentation, including a PDF user manual, please refer to the official product page or contact customer service. (Note: A PDF user manual is available at https://manuals.plus/m/b4b10ecb5528f1d6a701ef567296551b9b626bfac80e636b3dd0bde95b98da1a)