Ziqqucu Universal Control Board 300W

Contents

Universal Air Conditioning Fan Control Board Instruction Manual

Model: Universal Control Board 300W

Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Ziqqucu Universal Air Conditioning Fan Control Board. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Universal Air Conditioning Fan Control Board with remote and panel

Figure 1: Universal Air Conditioning Fan Control Board, Remote Control, and Control Panel.

Key Features:

  • High-quality PCB+ABS material construction.
  • Natural wind function for enhanced comfort.
  • Integrated 7-hour timer function.
  • High power output (300W) for stable performance.
  • Universal design for easy replacement and installation without welding.
  • Compact size for versatile application.
  • Includes an ultra-thin remote control for convenient operation.

Package Contents

  • 1 x Control Board (KTS-002)
  • 1 x Remote Control (SKQ MODEL-10)
  • 1 x Button Control Panel (KTS Controller)

Setup and Installation

Safety Precautions:

  • Ensure the power supply to the appliance is disconnected before beginning any installation work.
  • Only qualified personnel should perform electrical installations.
  • Verify all connections are secure to prevent short circuits or electrical hazards.

Pre-installation Steps:

  1. Before connecting the new control board, carefully identify all existing connection lines from your fan unit.
  2. Confirm the function of each line (e.g., power, fan speed, swing, cold).
  3. It is recommended to test the fan motor directly by applying power to it (bypassing the control board) to ensure the motor itself is in good working condition. Only proceed with connecting to the new control board if the motor operates normally.

Wiring Instructions:

Refer to the wiring diagram below for correct connections. Ensure each wire is connected to its corresponding terminal on the control board.

Wiring diagram for the universal air conditioning fan control board

Figure 2: Wiring Diagram for the Control Board.

  • AC220V Power Input (L, N): Connect the main power supply lines.
  • Public COM: Common line for various functions.
  • SW (Swing): Connect to the swing motor.
  • COLD: Connect to the cold air function component (e.g., water pump for evaporative coolers).
  • FAN (Speed Line 1, 2, 3): Connect to the respective fan speed windings.
  • Motor Zero Line: Connect the common return line for motors.
  • Matching Panel: Connect the ribbon cable from the button control panel to the designated connector on the main board.
Warning and simplified wiring diagram on product packaging

Figure 3: Simplified Wiring Diagram and Warning from Packaging.

Important Warning from Packaging:

  1. Firstly, the board detects whether the fan can work properly, and then it detects whether the load has short circuit components.
  2. Verify that the connection is okay before the power test can be carried out!

Operating Instructions

The control board can be operated using either the included remote control or the button control panel.

Remote Control (SKQ MODEL-10):

  • ON/SPEED: Press to power on the fan. Subsequent presses cycle through fan speeds (Low, Medium, High).
  • TIME: Press to set the operating timer (e.g., 1 hour, 2 hours, 4 hours).
  • SWING: Press to activate or deactivate the oscillation (swing) function.
  • COLD: Press to activate or deactivate the cold air function.
  • SLEEP: Press to activate or deactivate sleep mode, which typically reduces fan speed and noise.
  • OFF: Press to power off the fan.

Button Control Panel (KTS Controller):

  • ON/OFF: Press to power on or power off the fan.
  • Speed (SLOW, Medium, High): Press the Speed button to cycle through fan speeds.
  • Swing: Press to activate or deactivate the oscillation function.
  • Cold: Press to activate or deactivate the cold air function.
  • Time (1H, 2H, 4H): Press the Time button to set the operating timer.

The board also features a natural wind function, which simulates natural breezes by varying fan speed.

Maintenance

  • Keep the control board and its components dry. Avoid exposure to water or excessive humidity.
  • Clean the control panel and remote control with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Ensure proper ventilation around the control board if it is housed in an enclosure.
  • Periodically check wiring connections for looseness or corrosion.

Troubleshooting

  • No Power / Fan Not Responding:
    • Check the main power supply to the fan unit.
    • Verify all wiring connections according to the diagram (Figure 2).
    • Ensure the fan motor is functional (as tested in pre-installation).
    • Check for any physical damage to the control board or components.
  • Specific Function Not Working (e.g., Swing, Cold):
    • Check the wiring for that specific function.
    • Ensure the corresponding motor or component is functional.
  • Remote Control Not Working:
    • Ensure the remote control has a working battery (CR2025 button cell). The remote ships with a built-in battery.
    • Check for any obstructions between the remote and the control board's IR receiver.
  • Short Circuit Detection: The board has built-in detection for short circuits. If the fan does not operate, first ensure the fan motor is working, then check for any shorted components in the load.

Specifications

ParameterValue
Input VoltageAC110-220V (50/60HZ)
Fan Output Power300W
Pendulum Wind Power100W
Cold Wind Power100W
Main Board Dimensions (L x W)86mm x 40mm (3.38in x 1.57in)
Remote Control Dimensions (L x W)85mm x 40mm (3.34in x 1.57in)
Control Panel Dimensions (L x W)88mm x 40mm (3.46in x 1.57in)
Total WeightApproximately 83.1g
TypeDrive IC
ConditionNew
OriginMainland China
Dimensions of the control board, remote, and panel

Figure 4: Component Dimensions.

User Tips

  • This control board is an effective replacement part for repairing various air conditioning fans and electric fans.
  • Users have found it to be a perfect fit and easy to install, successfully fixing their fan units.
  • Always double-check all connections before powering on for the first time to ensure proper operation and prevent damage.

Warranty and Support

For warranty information, please refer to the terms provided by your retailer or contact the seller directly. For additional technical details or support, you may consult the official user manual PDF available at: User Manual PDF.