1. Introduction
The Gaqqee HW-400 Car Paint Thickness Tester is a precision instrument designed for non-destructive measurement of coating and paint thickness on metal surfaces. It utilizes principles of electromagnetic induction and eddy current effect to automatically detect substrate characteristics. This device is widely used in manufacturing, metal processing, chemical industry, commodity inspection, and laboratories, providing simple and convenient operation with high accuracy.
Its large screen display shows the working mode, number of readings, and current capacity, making it an essential tool for material surface treatment in various environments, including workshops and outdoor settings.
Figure 1: Gaqqee HW-400 Paint Thickness Tester and included accessories.
2. Safety Information
- Always handle the device with care to prevent damage to the probe or display.
- Do not expose the device to extreme temperatures, humidity, or corrosive environments.
- Ensure batteries are inserted correctly according to polarity markings. Remove batteries if the device will not be used for an extended period.
- Keep the device away from strong magnetic fields, which may affect its accuracy.
- This device is for non-destructive testing; avoid using it on surfaces that may be damaged by light pressure from the probe.
3. Package Contents
Please check the package for the following items:
- HW-400 Host Unit (1)
- User Manual (1)
- Calibration Sheets (6 pieces: 0.05mm, 0.10mm, 0.25mm, 0.50mm, 1.00mm, 2.00mm) (1 set)
- Iron Sheet (1)
4. Product Overview
The HW-400S features a high-definition LED display for clear readings in various lighting conditions and a highly sensitive probe for accurate measurements.
Figure 2: High Definition LED Display for easy readability.
Figure 3: Highly Sensitive Probe for accurate magnetic (Fe) and non-magnetic (NFE) coating detection.
Figure 4: Key features including HD Display, High Precision Probe, and Anti-Slip Groove Design.
4.1. Device Layout and Functions
Figure 5: HW-400S Labeled Diagram
- Probe: The sensor used to contact the surface for measurement.
- Probe mode: Displays the current measurement mode (AUTO, magnetic induction (F), vortex (NFE)).
- Measurement reading: Shows the thickness value.
- Statistical display: Provides average, minimum, maximum, and total number of readings.
- Low power indicator: Alerts when battery is low.
- Power on/off button: Turns the device on or off.
- Probe mode switch / Clear statistics button: Toggles probe modes and clears statistical data.
- Backlight switch / Automatic shutdown switch: Controls display backlight and automatic shutdown feature.
- Unit switching button: Cycles through measurement units (um micron, mm mm, Mill mils).
- Substrate properties: Indicates the detected substrate type (Fe: iron; NFE: non-iron).
- Automatic shutdown instruction: Icon indicating auto-shutdown is active.
- Zero calibration / Switching average/minimum/maximum/number button: Initiates zero calibration and cycles through statistical views.
- Unit switch button: Toggles measurement units.
5. Specifications
| Attribute | Value |
|---|---|
| Model Number | HW-400 |
| Material | ABS |
| Resolution | 0.01mm / 1mil |
| Measurement Range | 0-2000 μM |
| Measurement Accuracy | ±(3%+1um) |
| Power Supply | 2 * 1.5V AAA batteries (not included) |
| Working Temperature | -10°C ~ +50°C |
| Color Options | Black, White, Red |
| Battery Included | No |
| With Backlight Or Not | Yes (switchable) |
| Certification | CE |
| Feature 1 | Battery level indication |
| Feature 2 | Automatic shutdown function |
| Feature 3 | Ultra precision resolution 1um |
| Feature 4 | FE/NFE coating measurement |
| Feature 5 | Automotive paint 0-2000um |
6. Setup
6.1. Battery Installation
- Locate the battery compartment cover on the back of the device.
- Slide or unclip the cover to open it.
- Insert two (2) 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Close the battery compartment cover securely.
6.2. Power On/Off
- To Power On: Press the Power On/Off button (usually the central button with a power symbol). The display will light up.
- To Power Off: Press and hold the Power On/Off button for a few seconds, or the device will automatically shut down after a period of inactivity (if the automatic shutdown function is enabled).
7. Operation
7.1. Basic Measurement
- Ensure the device is powered on.
- Place the probe firmly and perpendicularly onto the surface to be measured. The device will automatically detect the substrate type (Fe for magnetic, NFE for non-magnetic) and display the coating thickness.
- Read the measurement value displayed on the screen.
- Lift the probe from the surface to prepare for the next measurement.
7.2. Changing Measurement Units
Press the 'mils um/mm' button (Unit switch button) to cycle through the available measurement units: micrometers (um), millimeters (mm), and mils.
7.3. Statistical Display
The device can display statistical data such as average (AVG), minimum (MIN), maximum (MAX) readings, and the total count (CNT) of measurements. Use the 'zero calibration / switching average/minimum/maximum/number' button to cycle through these statistical views.
7.4. Backlight Control
Press the 'backlight switch' button to turn the display backlight on or off, improving visibility in different lighting conditions.
8. Calibration
Regular calibration ensures the accuracy of your measurements. The HW-400S supports both zero calibration and multi-point calibration.
Figure 6: Calibration setup showing standard aluminum and various thickness sheets.
8.1. Zero Calibration
Zero calibration is performed on an uncoated metal substrate (e.g., the included iron sheet or standard aluminum) to establish a baseline.
- Ensure the device is in measurement mode.
- Place the probe firmly on the uncoated metal substrate.
- Press the 'ZERO CAL' button (part of the 'zero calibration / switching average/minimum/maximum/number' button) to perform zero calibration. The display should show '0.00' or a value very close to zero.
8.2. Multi-point Calibration
Multi-point calibration uses known thickness sheets to fine-tune the device's accuracy across its measurement range.
- Perform zero calibration first (as described above).
- Place one of the included calibration sheets (e.g., 0.05mm) on the uncoated metal substrate.
- Place the probe firmly on the calibration sheet.
- Adjust the reading to match the known thickness of the sheet using the calibration buttons (refer to the device's specific calibration menu if available, or follow on-screen prompts).
- Repeat for other calibration sheets (0.10mm, 0.25mm, 0.50mm, 1.00mm, 2.00mm) to ensure accuracy across the range.
9. Maintenance
- Cleaning: Wipe the device and probe with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a dry, dust-free environment at room temperature. Remove batteries if storing for extended periods to prevent leakage.
- Probe Care: Keep the probe tip clean and free from debris. Avoid scratching or damaging the probe surface, as this can affect measurement accuracy.
- Battery Replacement: Replace batteries when the low power indicator appears on the display.
10. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Dead or incorrectly installed batteries. | Replace batteries or check polarity. |
| Inaccurate readings. | Needs calibration; dirty probe; incorrect measurement mode. | Perform calibration; clean probe; ensure correct mode (Fe/NFE). |
| Display is dim or flickering. | Low battery; backlight setting. | Replace batteries; adjust backlight setting. |
| Device shuts off unexpectedly. | Automatic shutdown activated; low battery. | This is normal behavior for auto-shutdown; replace batteries if frequent. |
11. User Tips
- For consistent results, always ensure the probe is placed perpendicular to the surface and apply gentle, consistent pressure.
- Calibrate the device regularly, especially when measuring different types of substrates or after prolonged storage.
- Utilize the statistical display features (AVG, MIN, MAX) to get a comprehensive understanding of coating thickness variations across a surface.
- The automatic shutdown feature helps conserve battery life; remember to replace batteries when the low power indicator appears.
12. Warranty and Support
For detailed warranty information and technical support, please refer to the official product documentation or contact the seller directly. Additional item guides and documents, including a PDF user manual, may be available for download from the product's purchase page or the manufacturer's website. A PDF version of the user manual can be found at: User manual (PDF).