JFIND K DCAN For BMW

Contents

BMW K+DCAN Diagnostic Cable User Manual

1. Introduction

This manual provides comprehensive instructions for the installation, setup, and operation of your JFIND K+DCAN diagnostic cable for BMW vehicles. This tool is designed to interface with your BMW's onboard diagnostic system, allowing for fault code reading, data logging, and other diagnostic functions.

The K+DCAN cable features an FTDI FT232RL chip, ensuring reliable communication with your vehicle and computer. It supports BMW models manufactured between 1998 and 2013.

2. Safety Information

Please read and understand all safety precautions before using this device. Improper use can lead to damage to the vehicle, the diagnostic tool, or personal injury.

  • Always ensure your vehicle's ignition is off before connecting or disconnecting the diagnostic cable.
  • Do not attempt to modify the cable or its internal components.
  • Keep the device away from moisture, extreme temperatures, and direct sunlight.
  • Use the device in a well-ventilated area.
  • Consult a professional mechanic if you are unsure about any diagnostic procedures.

3. Package Contents

Verify that all items are present in your package:

  • 1 x JFIND K+DCAN Diagnostic Cable
  • 1 x Software CD (Note: Refer to the 'Setup' section for recommended software download methods.)
  • (Optional) 1 x 20-pin to OBDII Adapter (for older BMW models)
K+DCAN Diagnostic Cable with Software CD
K+DCAN Diagnostic Cable and included Software CD.

4. Specifications

FeatureSpecification
Brand NameJFIND
Model NameK DCAN For BMW
Hardware VersionFTDI FT232RL
Software VersionBest version
Supported ModelsFor BMW 1998-2013 Years
Operating SystemWindows 7 32bit (Also compatible with Windows 10 64-bit with third-party drivers)
Item TypeCar Diagnostic Cables and Connectors
MaterialPlastic
Item Weight0.12 kg
Item Dimensions (L x W x H)19 cm x 14 cm x 2 cm
Package Dimensions (L x W x H)22 cm x 17 cm x 3 cm
Package Weight0.137 kg

5. Setup and Driver Installation

Proper installation of drivers and software is crucial for the K+DCAN cable to function correctly. Please follow these steps carefully.

5.1 Important Notes Before Installation

  • Copy all software links provided below and open them in a new browser tab. Do not click directly from AliExpress.
  • If a web page cannot be opened, try using Microsoft Edge browser.
  • Disable any antivirus software during the download and installation process to prevent interference.

5.3 Installation Video Guide

For a visual walkthrough of the installation process, please refer to the video below:

Play video
Watch video online
Video demonstrating the software and driver installation process for the K+DCAN cable.

5.4 Step-by-Step Driver and Software Installation (Windows XP/7 Example)

  1. Extract Software: Extract the downloaded software archives (e.g., EDIABAS, NCS EXPER, clcdata) to your C: drive. For example, extract EDIABAS to `C: emp` and then move the contents to `C: empin`.
  2. Set Environment Variable:
    1. Right-click 'My Computer' and select 'Properties'.
    2. Go to the 'Advanced' tab and click 'Environment Variables'.
    3. Under 'User variables for Administrator', click 'New'.
    4. For 'Variable name', enter `path`.
    5. For 'Variable value', enter the path to your EDIABAS BIN folder (e.g., `C: empin`). Click 'OK' on all windows to save changes.
  3. Connect Cable: Plug the K+DCAN USB cable into your computer. Windows should detect new hardware.
  4. Install FTDI Drivers:
    1. When the 'Found New Hardware Wizard' appears, select 'Install from a list or specific location (Advanced)'.
    2. Browse to the location where you extracted the `Driver_D_CAN_USB` folder (e.g., `C: emp tdi_drivers tdibus`).
    3. Follow the prompts to install the 'FT232R USB UART' driver.
    4. Repeat the process for the 'USB Serial Port' driver, browsing to the same driver folder.
    Device Manager showing USB Serial Converter and Ports (COM & LPT)
    Device Manager view after successful driver installation, showing 'USB Serial Converter' and 'USB Serial Port (COMx)'.
  5. Configure COM Port:
    1. Right-click 'My Computer' and select 'Manage'.
    2. In 'Computer Management', go to 'Device Manager'.
    3. Expand 'Ports (COM & LPT)'.
    4. Right-click on 'USB Serial Port (COMx)' (where 'x' is the assigned COM number) and select 'Properties'.
    5. Go to the 'Port Settings' tab, then click 'Advanced'.
    6. Change the 'COM Port Number' to COM1 (or any available COM port between 1 and 4 if COM1 is in use).
    7. Set 'Latency Timer (msec)' to 1.
    8. Click 'OK' on all windows to save changes.
  6. Create INPA Shortcut: Navigate to the INPA BIN folder (e.g., `C: empin`), right-click `INPALOAD.exe`, and select 'Send To' > 'Desktop (create shortcut)'.

6. Operation

Once the drivers and software are installed, you can begin using the K+DCAN cable for diagnostics.

  1. Connect to Vehicle: Locate your BMW's OBDII port. For newer models (post-2000), this is typically a 16-pin connector under the dashboard. For older models (1998-2000), you may need the 20-pin adapter, usually located under the hood.
  2. 20-pin to OBDII adapter with pin assignment diagram
    20-pin to OBDII adapter for older BMW models. Pin assignment: 19 to 4+5, 17+20 to 7, 15 to 15, 14 to 16.
  3. Turn on Ignition: Turn your vehicle's ignition to the ON position (engine off).
  4. Launch Software: Double-click the INPA shortcut on your desktop.
  5. Select Model: In the INPA software, select your BMW model (e.g., E46, E90).
  6. Perform Diagnostics: Navigate through the software menus to perform desired diagnostic functions such as reading error memory, identifying modules, or checking live data.

7. User Tips

  • Software Source: While a software CD is included, some users report issues with it (e.g., potential viruses). It is recommended to download the necessary diagnostic software (INPA, EDIABAS, NCS Expert, ISTA+) from trusted online communities or forums dedicated to BMW diagnostics.
  • Windows 10 Compatibility: Although the official operating system is Windows 7 32-bit, many users have successfully used the K+DCAN cable on Windows 10 64-bit. This often requires finding compatible third-party drivers and specific software versions (e.g., ISTA+).
  • Driver Recognition: If your device is recognized as a 'USB Serial Converter' instead of 'Ports (COM & LPT)' in Device Manager, ensure you have correctly installed the FTDI drivers and configured the COM port settings as described in the 'Setup' section.

8. Troubleshooting

If you encounter issues, try the following troubleshooting steps:

  • Software Not Launching/Connecting:
    1. Ensure all drivers are correctly installed and the COM port is configured to COM1 (or another low number) with a Latency Timer of 1ms.
    2. Verify that your antivirus software is temporarily disabled during installation and initial use.
    3. Check that the cable is securely connected to both the vehicle and the computer.
    4. Ensure the vehicle's ignition is on.
  • "Registry Value RxFIFO or TxFIFO have wrong data!" Error: This error in INPA typically indicates incorrect COM port settings. Revisit step 5.4.6 to ensure the Latency Timer is set to 1ms.
  • Cable Not Detected: Try plugging the cable into a different USB port on your computer. Ensure the USB port is functional.
  • No Communication with Vehicle: Double-check that the correct BMW model is selected in the diagnostic software. Verify that the vehicle's battery is sufficiently charged.
  • Software Download Issues: If you have trouble downloading software from the provided links, ensure you are copying the link and pasting it into a new browser tab, and consider using Microsoft Edge browser as recommended.

9. Maintenance

To ensure the longevity and optimal performance of your K+DCAN diagnostic cable:

  • Store the cable in a clean, dry place away from direct sunlight and extreme temperatures.
  • Avoid bending or kinking the cable excessively.
  • Clean the connectors periodically with a dry, lint-free cloth.
  • Do not use harsh chemicals or abrasive materials for cleaning.

10. Frequently Asked Questions

Q: Does this cable work with Windows 10?
A: While officially supported on Windows 7 32-bit, many users have successfully used the cable on Windows 10 64-bit. This often requires sourcing compatible third-party drivers and diagnostic software (e.g., ISTA+).
Q: What should I do if the software CD is corrupted or contains viruses?
A: It is recommended to download the necessary diagnostic software (INPA, EDIABAS, NCS Expert, ISTA+) from trusted online communities or forums dedicated to BMW diagnostics, rather than relying solely on the included CD.

11. Warranty and Support

For any issues not covered in this manual, please contact the seller or manufacturer for support. Keep your purchase receipt for warranty claims.

You can also refer to the official user manual PDF for additional information: User manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.