1. Product Overview
The XY-160D is a high-power dual DC motor drive module designed for industrial applications. It features a double H-bridge configuration, allowing it to drive two DC motors simultaneously with a single channel current of up to 7A and a peak current of 50A. This module is built for stability and reliability, incorporating signal optocoupler isolation, undervoltage protection, and compliance with EMC specifications for electromagnetic compatibility.
Key Features:
- Dual H-bridge design for simultaneous control of two DC motors.
- High current capability: 7A rated, 50A peak per channel.
- Wide voltage input range: 6.5V to 27V.
- Signal optocoupler isolation for enhanced protection.
- Integrated undervoltage protection.
- Designed for electromagnetic compatibility (EMC).
- Electrostatic discharge (ESD) protection for industrial-grade reliability.
2. Safety & Warnings
Please read all instructions carefully before using this product. Failure to follow these instructions may result in damage to the product or personal injury.
- This module is an electronic component and should be handled with care.
- Ensure the power supply voltage is within the specified range of 6.5V-27V. Exceeding 27V may damage the module.
- It is recommended to connect a 15A fuse in series with the power input for protection.
- The motor interface must not be short-circuited. A 10A fuse in series with each motor is recommended.
- Do not expose the module to water or excessive moisture.
- Inspect the module for any damage before each use. Do not use if damaged.
- Follow proper installation and operation guidelines to prevent injury or damage.
3. Product Specifications
| Parameter | Value |
|---|---|
| Model | XY-160D |
| Type | Voltage Regulator (Motor Drive Module) |
| Package | DIP |
| Application | Computer (General electronic projects) |
| Supply Voltage | 6.5V - 27V DC |
| Rated Output Current (per motor) | 7A |
| Peak Output Current (per motor) | 50A |
| Dissipation Power | 1W (typical, actual depends on load) |
| Operating Temperature | -25°C to +80°C |
| PWM Frequency Range | 0 - 10KHz |
| PWM Minimum Pulse Width | 10us |
| Control Signal Voltage | 3V - 6.5V |
| Product Dimensions (L*W*H) | 55mm * 55mm * 16mm |
| Installation Hole Diameter | 3mm |
| Condition | New |
| Origin | Mainland China |

4. Setup and Installation
This section details the physical installation and initial wiring of the XY-160D motor drive module.
4.1 Physical Installation
- The module has 3mm diameter installation holes. When mounting, ensure there is no short circuit on the back of the circuit board.
- It is recommended to use insulation pads or copper columns to raise the circuit board and prevent contact with mounting surfaces or other components.
4.2 Wiring Connections
Refer to the diagrams below for proper connection of power, motors, and control signals.

Connection Points Explained:
- Power Input: Connect your DC power supply (6.5V-27V) to the designated power terminals. Ensure correct polarity. A 15A fuse in series with the positive power line is highly recommended.
- Motor A Output (OUT1/OUT2): Connect the first DC motor to these terminals.
- Motor B Output (OUT3/OUT4): Connect the second DC motor to these terminals.
- Control Signals: These pins accept 3V-6.5V logic signals from your microcontroller or control system.
- ENA (Enable): Input for PWM signal to control motor speed.
- IN1/IN2: Control direction for Motor A.
- IN3/IN4: Control direction for Motor B.

Important Wiring Notes:
- Always ensure the power supply is off before making or changing any connections.
- Double-check all polarities before applying power.
- Use appropriate wire gauges for the expected current draw of your motors.
- It is crucial to avoid short-circuiting the motor interfaces. Consider adding a 10A fuse in series with each motor for protection.
5. Operating Instructions
The XY-160D module uses PWM (Pulse Width Modulation) signals for speed control and logic signals for direction control.
5.1 Motor Direction Control
The direction of each motor is controlled by two input pins (IN1/IN2 for Motor A, IN3/IN4 for Motor B). The control signal voltage should be between 3V and 6.5V.
| Input (INx) | Input (INy) | Motor Action |
|---|---|---|
| High | Low | Forward Rotation |
| Low | High | Reverse Rotation |
| Low | Low | Brake / Stop |
| High | High | Brake / Stop |
Note: 'High' typically refers to the control signal voltage (3V-6.5V) and 'Low' refers to 0V (Ground).
5.2 Motor Speed Control (PWM)
The speed of the motors is controlled by applying a PWM signal to the ENA (Enable) terminal. The PWM frequency should be within 0-10KHz, with a minimum pulse width of 10us.
- A higher duty cycle PWM signal will result in higher motor speed.
- A lower duty cycle PWM signal will result in lower motor speed.
- To stop the motor, set the ENA pin to Low or use the direction control pins for braking.
6. Maintenance
The XY-160D motor drive module is designed for durability, but proper maintenance can extend its lifespan and ensure reliable operation.
- Cleaning: Keep the module clean and free from dust, dirt, and debris. Use a soft, dry brush or compressed air for cleaning. Avoid using liquids.
- Storage: When not in use, store the module in a dry, anti-static environment, away from direct sunlight and extreme temperatures.
- Inspection: Periodically inspect the module for any signs of physical damage, loose connections, or burnt components. Address any issues promptly.
- Thermal Management: Ensure adequate ventilation around the module, especially during high-current operation, to prevent overheating.
7. Troubleshooting
If you encounter issues with your XY-160D module, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Motor not moving | Incorrect power supply voltage; Loose connections; Incorrect control signals; Motor fault. | Verify power supply (6.5V-27V) and polarity. Check all wiring connections. Ensure INx/INy signals are correct and ENA is high or receiving PWM. Test motor independently. |
| Motor moves in wrong direction | Incorrect IN1/IN2 or IN3/IN4 logic. | Review the Motor Direction Control table and adjust your control signals accordingly. You can also reverse motor wires. |
| Motor speed is inconsistent or too low/high | Incorrect PWM signal to ENA; Motor load too high. | Check PWM frequency (0-10KHz) and duty cycle. Ensure PWM minimum pulse width is at least 10us. Reduce motor load if possible. |
| Module overheating | Excessive current draw; Insufficient ventilation. | Ensure motor current does not exceed 7A rated (50A peak). Add heatsinks if necessary. Improve airflow around the module. Check for short circuits. |
| Module not powering on | No power supply; Reverse polarity; Blown fuse. | Check power supply connection and voltage. Verify polarity. Inspect power input fuse (if installed). |
8. User Tips
- For projects requiring precise speed control, ensure your microcontroller's PWM output is stable and within the specified frequency range.
- When driving high-current motors, always use thick gauge wires for power and motor connections to minimize voltage drop and heat generation.
- Consider adding a small heatsink to the main driver ICs if operating continuously at high currents, even though it's industrial grade.
- Always test your motor and power supply setup with low current and voltage first before scaling up to full power.
9. Warranty and Support
For technical support or warranty inquiries, please contact the manufacturer or your point of purchase.
Manufacturer Information:
- Company: Shenzhen xingyao electronics Co.,Ltd.
- Address: 917 Nanguang Jiejia Building, Shennan Middle Road, Huaqiangbei Street, Futian District, Shenzhen, China
- Email: 2753728350@qq.com
- Telephone: +86-15376019940
EU Authorized Representative:
- Company: TOCYA TRADING
- Address: 79 rue de patay, 75013, Paris
- Email: TOCYATRADING75013@outlook.com
- Telephone: +33-143443019
10. Compliance Information
This product complies with relevant international standards and directives.
Certificate of Conformity:
Certificate Number: BTT20260209587RC-1
The EUT (Equipment Under Test) described above has been tested and found in compliance with the council RoHS 2.0 Directive (EU) 2015/863 (EU 2017/2102 amending Annex II to Directive 2011/65/EU). This certificate is only valid in connection with the test report.
Test Standards:
- IEC 62321-1:2013
- IEC 62321-3-1:2013
- IEC 62321-4:2013+AMD1:2017
- IEC 62321-5:2013
- IEC 62321-6:2015
- IEC 62321-7-1:2015
- IEC 62321-7-2:2017
- IEC 62321-8:2017
After preparation of the necessary technical documentation and the EC conformity declaration, the required RoHS marking can be affixed on the product. Other relevant directives have to be observed.
Test Report No: BTT20260209587RR-1
Testing Laboratory: Shenzhen Bettar Test Technology Co., Ltd.