1. Introduction
The FOXWELL NT301 PLUS is an advanced 2-in-1 car diagnostic tool designed to provide comprehensive vehicle diagnostics and battery testing capabilities. This device supports all 10 OBDII service modes, including live data, O2 sensor tests, and more, for OBDII/EOBD compliant vehicles manufactured worldwide since 1996. Additionally, it functions as a 12V battery tester, capable of assessing regular flooded, AGM flat plate, AGM spiral, and gel batteries. It offers a quick, easy, and affordable solution for technicians and car owners to monitor battery charging status, check battery health, and identify potential faults.
2. Safety Information
For your own safety, the safety of others, and to prevent damage to the equipment and vehicles, read this manual thoroughly before operating your OBDII & Battery tester. The safety messages presented below and throughout this user's manual are reminders to the operator to exercise extreme care when using this device. Always refer to and follow safety messages and test procedures provided by the vehicle manufacturer. Read, understand, and follow all safety messages and instructions in this manual.
2.1 Safety Message Conventions Used
We provide safety messages to help prevent personal injury and equipment damage. Below are signal words we used to indicate the hazard level in a condition.
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury to the operator or to bystanders.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury to the operator or to bystanders.
Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor injury to the operator or to bystanders.
2.2 Important Safety Instructions
Always use your OBDII & Battery tester as described in the user's manual, and follow all safety messages.
- Do not route the test cable in a manner that would interfere with driving controls.
- Do not exceed voltage limits between inputs specified in this user's manual.
- Always wear ANSI approved goggles to protect your eyes from propelled objects as well as hot or caustic liquids.
- Fuel, oil vapors, hot steam, hot toxic exhaust gases, acid, refrigerant, and other debris produced by a malfunction engine can cause serious injury or death. Do not use the OBDII & Battery tester in areas where explosive vapor may collect, such as in below-ground pits, confined areas, or areas that are less than 18 inches (45 cm) above the floor.
- Do not smoke, strike a match, or cause a spark near the vehicle while testing and keep all sparks, heated items, and open flames away from the battery and fuel/fuel vapors as they are highly flammable.
- Keep a dry chemical fire extinguisher suitable for gasoline, chemical, and electrical fires in the work area.
- Always be aware of rotating parts that move at high speed when an engine is running and keep a safe distance from these parts as well as other potentially moving objects to avoid serious injury.
- Do not touch engine components that get very hot when an engine is running to avoid severe burns.
- Block drive wheels before testing with the engine running. Put the transmission in park (for automatic transmission) or neutral (for manual transmission). Never leave a running engine unattended.
- Do not wear jewelry or loose-fitting clothing when working on the engine.
3. Technical Specifications
| Feature | Specification |
|---|---|
| Display | 2.8" TFT color display |
| Working Temperature | 0 to 60 °C (32 to 140 °F) |
| Storage Temperature | -20 to 70 °C (-4 to 158 °F) |
| Power Supply | 8-18V vehicle power |
| Supported Protocols | J1850PWM, J1850-VPW, ISO9141, KWP2000 (ISO 14230), CAN (Control Area Network ISO 11898) |
| Dimensions (L*W*H) | 145*94*32mm |
| Weight | 0.6kg |
| Software Update | Yes |
| Languages | Dutch, English, French, German, Italian, Portuguese, Russian, Spanish, Swedish |
| Certification | CE |
3.1 Accessory Descriptions
The NT301 PLUS comes with the following accessories:
- User's Manual: Provides detailed operation instructions.
- Battery Clips: Used to connect the device for battery testing functions.
- USB Cable: For connecting the device to a computer for software upgrades.
- Quick Start Guide: Includes basic instructions, NT Wonder update software, and update files.
4. Getting Started
This section outlines how to power the OBDII & Battery tester and provides an overview of its applications.
4.1 Providing Power to the OBDII & Battery Tester
The unit can be powered by:
- 12-volt vehicle power (via the OBDII port)
- USB connection to a personal computer (for updates and file transfer)
4.1.1 Connecting to Vehicle Power
The OBDII & Battery tester typically powers on automatically when connected to the vehicle's Data Link Connector (DLC).
- Locate the Data Link Connector (DLC), usually found under the dash on the driver's side.
- Connect the OBDII & Battery tester to the DLC.
- Switch the ignition key to the ON position.
- The OBDII & Battery tester will automatically boot up.
Never try to provide power for the OBDII & Battery tester from a USB connection when the OBDII & Battery tester is communicating with a vehicle.
4.1.2 Connecting to Personal Computer with USB Cable
The OBDII & Battery tester can be powered via its USB port when connected to a PC for software updates and transferring saved files.
- Insert the small end of the USB cable into the USB port on the right side of the OBDII & Battery tester and the large end into a computer.
- Press the power switch of the OBDII & Battery tester to power it on.
4.2 Application Overview
When the OBDII & Battery tester boots up, the Home screen displays all preloaded applications:
- OBDII/EOBD: Accesses OBDII screens for all 9 generic OBD system tests.
- Battery: Leads to battery testing functions.
- DTC Lookup: For diagnostic trouble code lookup.
- Review: Accesses tested data files.
- Print Data: Accesses the printing function.
- Setup: For adjusting default settings and preferences.
5. OBDII/EOBD Operations
The OBD-II/EOBD menu provides access to all OBD service modes, divided into sub-programs called 'Service $xx$' according to ISO 9141-2, ISO 14230-4, and SAE J1850 standards.
When the Diagnostics application is selected from the Home screen, the tester automatically detects the communication protocol. Once connected, a menu of available tests for the identified vehicle displays.
Not all function options are applicable to all vehicles. Available options may vary by year, model, and make. A "The selected mode is not supported!" message indicates incompatibility.
5.1 Read Codes
The Read Codes menu allows you to retrieve stored, pending, and permanent Diagnostic Trouble Codes (DTCs) from the control unit.
- Press the Read hot key or navigate to Read Codes in the Diagnostic Menu and press ENTER.
- Select Stored Codes, Pending Codes, or Permanent Codes and press ENTER.
- A list of codes and their descriptions will display.
If no DTCs are present, "No (Pending) Codes Found!" is displayed. The NT301 PLUS automatically reads correct DTC information based on the VIN for manufacturer-specific codes.
5.2 Erase Codes
This function clears all current and stored DTCs, as well as temporary ECU information including freeze frame data. Ensure all diagnostics are complete before clearing codes.
- Press the Erase hot key or navigate to Erase Codes in the Diagnostic Menu and press ENTER.
- Follow on-screen instructions to confirm.
- Recheck for codes; if any remain, repeat the process.
Erase Codes does not fix the problem. DTCs should only be erased after correcting the underlying condition(s). Ensure the ignition key is ON with the engine OFF when clearing codes.
5.3 Live Data
The Live Data menu allows viewing, recording, and playback of real-time PID (Parameter ID) data from the electronic control module.
5.3.1 View Data
View real-time PID data, including sensor data, switch operations, solenoids, and relays.
- Navigate to Live Data from the Diagnostic Menu and press ENTER.
- Select View Data and press ENTER.
- Choose Complete Data Set to view all supported PIDs or Custom Data Set to select specific parameters.
- Use UP/DOWN and LEFT/RIGHT keys to scroll through data.
- Press ENTER to view a PID graph if the PID provides a numeric reading.
- Press BACK to return to the diagnostic menu.
5.3.2 Record Data
Record PIDs to diagnose intermittent drivability problems.
- Select Record Data from the Live Data menu and press ENTER.
- Set up Complete Data Set or Custom Data Set as desired.
- Select a trigger mode (Manual Trigger or DTC Trigger) and press ENTER.
- Choose a memory location. If a location has an asterisk (*), a previous recording exists. You will be prompted to overwrite.
- Press ENTER to start recording or wait for DTC to trigger.
- Recording stops when memory is full or BACK key is pressed.
Do not operate the OBDII & Battery tester while driving. Always have two persons in the vehicle when recording – one to drive and the other to operate the tester.
5.3.3 Playback Data
Playback recorded PID data.
- Select Playback Data from the Live Data menu.
- Use UP/DOWN keys to select a memory area marked with an asterisk (*) and press ENTER.
- Use UP/DOWN keys to view recorded PIDs of each frame. Press BACK to exit.
5.4 View Freeze Frame
Freeze Frame data is a snapshot of critical vehicle operating conditions recorded when a DTC is set, helping to determine the cause of the fault.
- Select View Freeze Frame from the Diagnostic Menu.
- Use UP/DOWN and LEFT/RIGHT keys to scroll through data. If no freeze frame data is stored, a message will display.
- Press BACK to return to the Diagnostic Menu.
5.5 I/M Readiness Status Data
This option provides a snapshot of the emission system's operations, indicating if all monitors are OK, Incomplete (INC), or Not Applicable (N/A).
There are two types of I/M Readiness tests:
- Since DTCs Cleared: Shows monitor status since the last DTC clear.
- This Drive Cycle: Shows monitor status since the start of the current drive cycle.
To retrieve I/M Readiness Status data:
- Press the One-Click I/M Readiness Key on the keypad.
- Alternatively, navigate to I/M Readiness from the Diagnostic Menu and press ENTER.
- If supported, select a monitor type.
- Use UP/DOWN keys to scroll through data. Press BACK to exit.
To review I/M Readiness status, ensure the ignition key is ON with the engine OFF. Not all monitors are supported by all vehicles.
5.6 O2 Monitor Test
This function retrieves completed O2 sensor monitor test results, as required by OBD II regulations for fuel and emissions-related faults.
The O2 Monitor Test is not an on-demand test; sensors are tested when engine operating conditions are within specified limits. This function is not supported for CAN protocol vehicles.
To retrieve O2 monitor data:
- Highlight O2 Monitor Test from the Diagnostic Menu and press ENTER.
- A list of available sensors displays. Highlight an O2 sensor and press ENTER to confirm.
- A screen with details of the selected sensor displays. Use UP/DOWN and LEFT/RIGHT keys to scroll.
- Press BACK to exit.
5.7 On-Board Monitor Test
This function is useful after servicing or clearing a vehicle ECU's memory. It receives test results for emission-related powertrain components and systems not continuously monitored for non-CAN vehicles, and test data for CAN vehicles.
Test results do not necessarily indicate a faulty component or system.
To request on-board monitor test results:
- Highlight On-Board Monitor Test from the Diagnostic Menu and press ENTER.
- Depending on the vehicle protocol, a relevant screen will display.
- Highlight a test group and press ENTER to confirm.
- A screen with details of the selected sensor displays. Use UP/DOWN and LEFT/RIGHT keys to scroll.
- Press BACK to exit.
5.8 Component Test
The Component Test allows the OBDII & Battery tester to control the operation of vehicle components, tests, or systems.
Some manufacturers do not allow tools to control vehicle systems. The manufacturer sets the criteria to automatically stop tests. Refer to the appropriate vehicle service manual before using this function.
To perform a component test:
- Highlight Component Test from the Diagnostic Menu and press ENTER. A list of available tests displays.
- Highlight a system or component and press ENTER to start the test. The message "Command Sent!" will display.
- Press BACK to exit.
5.9 Request Vehicle Information
This function allows you to request the vehicle's VIN number, calibration ID(s), calibration verification numbers (CVN(s)), and in-use performance tracking for model year 2000 and newer OBD II compliant vehicles.
Available options will vary depending on the vehicle under test.
To request vehicle information:
- Highlight Vehicle Info. from the Diagnostic Menu and press ENTER.
- Follow on-screen instructions to send the command. A screen with available options displays.
- Highlight an option and press ENTER to view details.
- Press BACK to exit.
5.10 Modules Present
The OBDII & Battery tester identifies module IDs and communication protocols for OBD2 modules in the vehicle.
To view module IDs and communication types:
- Highlight Modules Present from the Diagnostic Menu and press ENTER.
- A screen with module IDs and protocols displays.
- Press BACK to exit.
6. Battery Testing Operations
This section details how to use the tester for car battery and charging system tests. The menu-driven display will guide you through the process.
6.1 Connecting the OBDII & Battery Tester for Battery Test
The tester powers on automatically when correctly connected to the battery. The preferred test position is at the battery terminals. If the battery is not accessible, you may test at the jumper post, but power measurement might be lower than the actual value.
To connect the tester:
- Clean the battery posts or side terminals.
- Connect the red clamp to the positive (+) terminal and the black clamp to the negative (-) terminal.
- Rock the clamps back and forth to ensure a firm connection.
Do not connect the tester to a voltage source greater than 30VDC; otherwise, you may damage the tester.
6.2 Battery Testing Procedure
The NT301 PLUS 12 Volt Automotive Battery Analyzer allows you to analyze battery health and charging status.
To start a battery test:
- From the Main Menu, press the ENTER button to start the test. The BAT. LOCATION menu will display.
- Scroll with the UP or DOWN button to highlight OUT OF VEHICLE or IN VEHICLE and press ENTER to select.
- Scroll with the UP or DOWN button to select the battery type (e.g., REGULAR FLOODED, AGM, GEL) from the BATTERY TYPE menu and press ENTER.
- Scroll with the UP or DOWN button to select the battery standard (e.g., CCA, CA, MCA, JIS) from the BATTERY STANDARD menu and press ENTER. (Note: Not all rating systems are available for each application. You can find the battery type and rating label on the battery itself.)
- Use UP or DOWN to change the measure range until you enter the correct range of your battery. Press ENTER to start the test.
- View test results on the screen. Depending on battery status, one of the following test results may display:
| Test Result | Interpretation |
|---|---|
| GOOD BATTERY | The battery is in good condition. |
| GOOD-RECHARGE | The battery is in good condition but low current. Fully charge the battery and return it to service. |
| CHARGE & RETEST | Fully charge the battery and retest. Failure to fully charge the battery before testing may result in inaccurate results. If you still get this message after fully charging, replace the battery. |
| REPLACE BATTERY | The battery is almost dead or the connection between the battery and battery cable is poor. Replace the battery and retest; or disconnect the battery cables and retest the battery using the out-of-vehicle test before replacing it. |
| BAD CELL-REPLACE | The battery may be damaged such as a broken cell or short circuit. Replace the battery and retest. |
The tester keeps the results of the last test only. When you start a new test, the last results are overwritten.
7. Maintenance
This section covers updating the device software, printing data, and accessing documentation.
7.1 Updating the OBDII & Battery Tester
The NT301 PLUS can be updated to ensure you have the latest diagnostic capabilities. You will need:
- NT301 PLUS OBDII & Battery Tester
- Update Tool NTWonder (software)
- PC or laptop with USB Ports and Internet Explorer
- USB cable
Minimum PC requirements:
- Operation System: Win98/NT, Win ME, Win2000, Win XP, VISTA, Windows 7
- CPU: Intel PIII or better
- RAM: 64MB or better
- Hard Disk Space: 30MB or better
- Display: 800*600 pixel, 16-bit true color display or better
- Internet Explorer 4.0 or newer
Do not disconnect the OBDII & Battery tester from the computer, or power off the computer during the update process.
To update the OBDII & Battery tester:
- Download the NT Wonder update tool and update files from the official website and save them to your computer.
- Unzip the update tool file and install the tool and driver.
- Double-click the desktop icon to launch the application.
- Click Setting and select your desired language.
- Connect the NT301 PLUS to the computer with the USB cable. Press and hold the HELP key while connecting the USB cable.
- When the NT301 PLUS enters Update Mode, the application will detect it automatically.
- Click <Update online> or <Update offline> to start updating.
Update online: NT Wonder automatically detects the latest software version from the server. Update offline: Update files are stored locally from previous online updates.
7.2 Printing Data
The Print Data function allows you to print test results via your computer. This function is not available when the device is in Update Mode.
To print test results:
- Download and launch NT Wonder (refer to section 7.1).
- Activate the application by clicking the Print Button from the menu.
- Connect the NT301 PLUS to the computer with the USB cable.
- Use the LEFT/RIGHT key to select Print Data from the home screen of the NT301 PLUS and press ENTER.
- Use the UP/DOWN key to select desired data to print. To print all recorded data, select Print All Data.
- Press ENTER to load data to the edit box of NT Wonder. Use Clear to delete data or Copy to save to clipboard.
- With the printer connected, use the Print key in NT Wonder to print the data. Press the BACK key to return to the home screen.
7.3 Searching DTC
The Search DTC option allows you to look up Diagnostic Trouble Codes.
To search DTC:
- Download and launch NT Wonder (refer to section 7.1).
- Start the application by clicking the Search DTC Button from the menu.
- Input the valid code number, and its definition will be highlighted.
7.4 User Manual (PDF)
The User Manual option opens a screen that allows you to read the manual in PDF format.
To read the manual:
- Download and launch NT Wonder (refer to section 7.1).
- Activate the application by clicking the User Manual Button from the menu.
- Double-click to open the manual you want to check.
A PDF version of this user manual is available for download: FOXWELL NT301PLUS User Manual (PDF).
7.5 Update Tool Settings
The Settings option allows you to configure the language and style of the update tool, and to automatically check for update files from the server.
To set up the update tool:
- Download and launch NT Wonder (refer to section 7.1).
- Activate the application by clicking Settings from the menu.
- Select the language and style from the left to right columns.
- Select and tick "Auto check for updates" at the bottom, then press Apply to confirm.
8. System Setup
This section explains how to program the OBDII & Battery tester to meet your specific needs. When the Setup application is selected, a menu with service options displays.
8.1 Select Language
This option allows you to choose the system language.
To configure system language:
- Highlight Setup from the home screen and press ENTER.
- Highlight Language from the menu and press ENTER.
- Use UP/DOWN keys to select a language and press ENTER to confirm. Press BACK to exit.
8.2 Configure Monitors
This menu allows you to configure required monitors for spark ignition and compression ignition, set the number of monitors to pass diagnosis, and restore default settings.
There are two types of monitors: continuous and non-continuous. Continuous monitors are constantly tested, while non-continuous monitors require specific conditions to be met.
To configure monitors:
- Highlight Configure Monitors from the Setup menu and press ENTER.
- A screen with optional monitors displays.
8.2.1 Spark IGN Required Monitors (Gasoline Engines)
To configure spark IGN required monitors:
- Highlight Spark IGN Required Monitors and press ENTER.
- Use RIGHT key to select/deselect a monitor or LEFT key to deselect all. Press ENTER to confirm, BACK to cancel.
8.2.2 Compression IGN Required Monitors (Diesel Engines)
To configure spark compression required monitors:
- Highlight Compression IGN Required Monitors and press ENTER.
- Use RIGHT key to select/deselect a monitor or LEFT key to deselect all. Press ENTER to confirm, BACK to cancel.
8.2.3 Allowed INC Monitors
This allows selecting 0, 1, 2, or 3 INC monitors for emissions tests, accommodating different regional standards.
To configure allowed INC monitors:
- Highlight Allowed INC Monitors and press ENTER.
- Scroll with UP/DOWN keys to select the desired number and press ENTER to confirm, BACK to cancel.
8.2.4 Reset Factory Default
This option restores default configuration settings for monitors and deletes customized settings. Allowed INC Monitors will be set to 1.
To reset factory default:
- Highlight Reset Factory Default and press ENTER.
- Answer Yes to confirm or No to abort.
8.3 Unit of Measure
Choose between US customary or metric units.
To change unit setup:
- Highlight Unit of Measure from the Setup menu and press ENTER.
- Use UP/DOWN keys to select an item (English/Metric) and press ENTER to save.
8.4 Key Beep Set
Turn the built-in speaker for key pressing on or off.
To set the key beep:
- Highlight Key Beep Set from the Setup menu and press ENTER.
- Use UP/DOWN keys to select Beep ON or Beep OFF and press ENTER to save.
8.5 Diag Beep Set
Turn the built-in speaker for diagnostics on or off.
To set the diag beep:
- Highlight Diag Beep Set from the Setup menu and press ENTER.
- Use UP/DOWN keys to select an item (e.g., For Monitor Ready, Beep With Light, Beep OFF) and press ENTER to save.
8.6 Tool Self-test
This function checks the LCD display, keypad operation, and LED indicators.
8.6.1 Display Test
To test the display:
- Highlight Display Test from the Tool Self-test menu and press ENTER.
- Check for any missing spots on the LCD screen.
- Press BACK to quit.
8.6.2 Keypad Test
To test the keypad:
- Highlight Keyboard Test from the Tool Self-test menu and press ENTER.
- Press any key. The key name or scroll direction should display.
- Double-press BACK to return.
8.6.3 LED Test
To test the LED indicators:
- Highlight LED Test from the Tool Self-test menu and press ENTER.
- The Green, Yellow, and Red indicators will flash randomly. They will turn off when you exit by pressing any key.
8.7 Tool Information
This option displays information about your OBDII & Battery tester, including serial number and software version.
To view tool information:
- Highlight Setup from the home menu, then highlight About and press ENTER.
- A screen with detailed information displays.
- Press BACK to exit.
9. Troubleshooting
This section provides solutions to common issues you might encounter with your FOXWELL NT301 PLUS.
- Device does not power on:
- Ensure the device is correctly connected to the vehicle's DLC or a PC via USB.
- Check vehicle's ignition is in the ON position when connecting to the DLC.
- Verify the USB cable is functional and properly connected to the PC.
- Ensure the vehicle battery has sufficient charge if testing battery functions.
- Communication error with vehicle:
- Confirm the vehicle is OBDII/EOBD compliant (typically 1996 and newer for US vehicles).
- Check the connection to the DLC for looseness or damage.
- Verify the ignition is ON and the engine is off (KOEO) or running (KOER) as required by the specific test.
- Try the device on another compatible vehicle to rule out a vehicle-specific issue.
- "The selected mode is not supported!" message:
- This indicates that the specific function or test is not supported by your vehicle's ECU or protocol. This is normal for some older or specific vehicle models.
- Inaccurate battery test results:
- Ensure battery terminals are clean and clamps are firmly connected.
- If testing "IN VEHICLE", ensure all accessory loads are off and the ignition is off.
- For "CHARGE & RETEST" results, fully charge the battery before retesting.
- If testing at a jumper post, results might be slightly lower than actual battery terminal readings.
- Update issues with NTWonder:
- Ensure your PC meets the minimum system requirements.
- Verify a stable internet connection for online updates.
- Do not disconnect the device or power off the PC during the update process.
- Ensure the correct drivers are installed for the NT301 PLUS.
10. User Tips
- Keep Software Updated: Regularly check for software updates using the NTWonder tool to ensure compatibility with the latest vehicle models and diagnostic protocols.
- Clean Connections: Always ensure the OBDII connector and battery clamps are clean and free of corrosion for reliable connections and accurate readings.
- Understand DTCs: When a Diagnostic Trouble Code (DTC) appears, don't just clear it. Research the code to understand the underlying issue before attempting repairs or clearing the code.
- Battery Testing Best Practices: For the most accurate battery test results, perform tests on a fully charged battery and ensure all vehicle accessories are off.
- Safety First: Always prioritize safety. Wear appropriate personal protective equipment (PPE) like safety goggles and ensure proper ventilation when working on vehicles.
- Refer to Vehicle Manual: For specific vehicle-related diagnostic procedures or component locations, always consult your vehicle's service manual.
- Practice with Live Data: Familiarize yourself with the Live Data function to monitor various sensor readings in real-time. This can help in diagnosing intermittent issues that don't always trigger a DTC.
11. Warranty and Support
11.1 One-Year Limited Warranty
Shenzhen Foxwell Technology Co., Ltd ("FOXWELL") warrants this product to be free of defects in material and workmanship at the time of its original purchase for a period of one (1) year. If the product fails under normal use during this period due to defects, FOXWELL will, at its sole option, repair or replace the product according to the terms and conditions herein.
Terms and Conditions:
- Repaired or replaced products are warranted for the remainder of the original warranty period. No charge for parts or labor.
- This limited warranty does not cover abnormal use, improper storage, unauthorized modifications, misuse, neglect, abuse, accident, alteration, improper installation, or damage from external causes (e.g., collision, fire, flood, battery leakage, improper electrical source, or use with non-FOXWELL products).
- The customer bears the cost of shipping the product to FOXWELL; FOXWELL bears the cost of shipping it back after service.
- FOXWELL does not warrant uninterrupted or error-free operation. For problems during the warranty period, return the product to the place of purchase, contact your local FOXWELL distributor, or visit www.foxwelltech.com.
- Include a return address, phone/fax number, problem description, and original invoice with date of purchase and serial number.
- Customers will be billed for parts or labor not covered by warranty.
- FOXWELL will repair the product within 30 days of receipt. If repairs cannot be completed within 30 days or after a reasonable number of attempts, FOXWELL will, at its option, provide a replacement or refund the purchase price (less a reasonable amount for usage).
- If a returned product's problem is not covered by warranty, the customer will be notified of repair costs. If the estimate is refused, the product will be returned freight collect. Post-warranty returns are subject to FOXWELL's normal service policies and customer responsibility for all shipping charges.
- Any implied warranty of merchantability or fitness for a particular purpose is limited to the duration of this one-year written warranty. This limited warranty is the consumer's sole and exclusive remedy. FOXWELL is not liable for special, incidental, punitive, or consequential damages.
- Some states do not allow limitations on implied warranties or exclusions of incidental/consequential damages, so these limitations may not apply to you. This warranty provides specific legal rights, and you may have other rights that vary by state.
11.2 Technical Assistance
For technical assistance, please visit our website at www.foxwelltech.us or send an email to support@foxwelltech.com.