Y&H GMI Series (300W-700W)

Contents

Y&H GMI Series Grid Tie Micro Inverter User Manual

Models: GMI-300W, GMI-350W, GMI-500W, GMI-600W, GMI-700W

1. Introduction

This manual provides essential information for the safe installation, operation, and maintenance of your Y&H GMI Series Grid Tie Micro Inverter. Please read this manual thoroughly before installing or using the product. Keep this manual for future reference.

The Y&H GMI Series Micro Inverter is designed to convert direct current (DC) from solar photovoltaic (PV) modules into alternating current (AC) for direct use in your home or to feed into the utility grid. It features Maximum Power Point Tracking (MPPT) to optimize power harvest from your solar panels.

2. Safety Information

DANGER! Risk of Electric Shock!

  • Read the entire user manual before operating this equipment. Failure to do so can result in serious injury, property damage, and/or electrical shock.
  • Use photovoltaic panel(s) ONLY with this equipment.
  • This equipment is an ON-GRID Microinverter. For proper operation, it must be connected to the power grid, and the power grid must be working correctly. The inverter will stop generating power if the grid stops working.
  • Do NOT exceed the PV panel(s) voltage over the inverter's maximum input voltage. Ensure the PV module's open-circuit voltage (VOC) and operating voltage (VMP) are within the inverter's specified input voltage range.
  • Do NOT exceed the PV panel(s) power over the inverter's maximum input power.
  • DC voltage sources pass through this equipment. Each circuit must be individually disconnected before servicing.
  • Do NOT cover other items on this equipment.
  • Do NOT remove the lid. Servicing must be performed by qualified service personnel.
  • When the PV array is exposed to light, it supplies DC voltage to this equipment. Exercise caution.
  • Install the inverter away from direct sunlight and direct rain exposure.

3. Product Overview

3.1. Basic Structure

The micro inverter features several key components for connection and operation:

Y&H GMI Micro Inverter with labels for input voltage, output voltage, panel input power, and DC max current.
Figure 1: Y&H GMI Micro Inverter Overview
  • PV Connector (to PV Module): Connects to your solar panels.
  • AC Connector F (to AC Cable): Connects to the AC grid cable.
  • Status Indicator: An LED light indicating the inverter's operational status.
  • Mounting Holes: For securing the inverter to a rack or surface.

3.2. Port Introduction and Unpacking

This video demonstrates the unpacking process and introduces the various ports and their connections.

Play video
Watch video online
Video 1: Unpacking and Port Introduction

The AC cable typically includes three wires: L (Brown for Live), N (Blue for Neutral), and G (Green & Yellow for Ground).

3.3. LED Display Indicator

The LED status indicator provides visual feedback on the inverter's current state:

  • Green light steady: The Microinverter is generating power normally.
  • Red light flashing: The Microinverter is in waiting mode (e.g., insufficient solar input, grid not detected).
  • Red light steady: Indicates a fault condition:
    • Island protection activated.
    • Over-temperature protection.
    • Over/low AC voltage protection.
    • Over/low DC voltage protection.
    • Over/low AC frequency protection.
    • General hardware fault.

4. Setup and Installation

Before installation, verify that the utility voltage at the point of common grid connection matches the voltage rating on the Microinverter label. Incorrect voltage matching can damage the inverter.

4.1. Attaching the Microinverter

Mark the desired location for the Microinverter on the racking, considering the PV module junction box and other obstructions. Mount the Microinverter securely using hardware recommended by your module racking vendor.

Man installing a micro inverter under a cabinet, demonstrating plug-and-play installation.
Figure 2: Plug-and-Play Installation Example
Solar balcony power station setup with micro inverter and solar panels on a balcony.
Figure 3: Solar Balcony Power Station Example

4.2. Connection Steps

  1. Connect PV Modules: Connect the DC output cables from your solar panels to the PV connectors (DC+ and DC-) on the micro inverter. Ensure that the PV panel voltage (VOC) does not exceed the inverter's maximum input voltage.
  2. Connect AC Cable: Connect the micro inverter's AC cable to the AC bus cable. Ensure correct wiring of Live (Brown), Neutral (Blue), and Ground (Green & Yellow). Do not exceed the maximum current of the AC bus cable.
  3. Install AC Branch Circuit Junction Box: Wire the conductors of the AC bus cable and connect the AC branch circuit junction box to the point of utility-grid interconnection.
  4. Double Check Connections: Verify that all Microinverters, connectors, and cables are correctly and securely connected.
  5. Activate AC Circuit Breaker: Turn ON the AC circuit breaker for each AC branch circuit of the Microinverter.
  6. Activate Main AC Breaker: Turn ON the main AC circuit breaker of the utility-grid. Your system will begin producing power after a 3-second safety delay period.

4.3. Wiring Schematics

The following diagram illustrates various wiring configurations for the GMI series micro inverters, depending on your grid type and voltage. It is crucial to select the correct wiring for your specific electrical system.

Detailed wiring schematics for GMI series micro inverters across different grid types: Single Phase 120/230V, 2-Phase 208/240V, and 3-Phase 380V/208-240V. The diagrams show connections from PV modules to micro inverters, then to an AC bus cable, through a distribution panel with breakers, and finally to the main grid meter.
Figure 4: GMI Series Wiring Schematics for various grid types

Note: The diagram shows configurations for Single Phase 120/230V, 2-Phase 208/240V, and 3-Phase 380V/208-240V systems. Always consult a qualified electrician if you are unsure about the correct wiring for your installation.

5. Operation

Once properly installed and connected, the Y&H GMI Micro Inverter operates automatically. When sufficient sunlight is available to the connected PV modules, the inverter will start converting DC power to AC power and feed it into your home's electrical system or the utility grid.

  • Automatic Operation: The inverter automatically starts and stops based on the availability of solar power and grid connection.
  • MPPT Functionality: The built-in MPPT ensures that the inverter extracts the maximum possible power from your solar panels under varying conditions, including partial shading.
Diagram comparing string inverter performance with microinverter performance under partial shading, showing microinverters maintain higher output.
Figure 5: Microinverter Advantage in Shaded Conditions

6. Specifications

Below are the detailed technical specifications for the Y&H GMI Series Grid Tie Micro Inverters:

ParameterDescriptionGMI500GMI600GMI700
Product SeriesGMI500-700 Series
ModelGMI
Input Data (DC, PV)
Number of Input MC4 Connector1 set
MPPT Voltage Range24V-40V
Operation Voltage Range18V-50V
Maximum Input Voltage50V
Startup Voltage18V
Maximum Input Power500W600W700W
Maximum Input Current20A24A28A
Output Data (AC)
Single-Phase Grid Type120V/230V
Rated Output Power490W580W650W
Maximum Output Power500W600W700W
Nominal Output Current120V:4.08A/230V:2.13A120V:4.83A/230V:2.52A120V:5.41A/230V:2.82A
Nominal Output Voltage120VAC/230VAC
Default Output Voltage Range@120VAC:80V-160V / @230VAC:180V-280V
Nominal Output Frequency50Hz/60Hz
Default Output Frequency Range@50Hz:47.5Hz-52.5Hz / @60Hz:57.5Hz-62.5Hz
Power Factor>0.99
Total Harmonic DistortionTHD <5%
Efficiency
Peak Efficiency92%
CEC Weighted Efficiency@120VAC:90% / @230VAC:90.5%
Nominal MPPT Efficiency99.9%
Night Power Consumption<700mW
Mechanical Data
Operating Ambient Temperature Range-40°C to +65°C
Storage Temperature Range-40°C to +85°C
Dimensions (WxHxD)30.5cm x 12.5cm x 5.5cm
Weight0.95kg
Waterproof GradeIP55
Cooling ModeNatural Convection - No Fans
Other Features
Transformer DesignHigh Frequency Transformers, Galvanically Isolated
Integrated GroundEquipment ground is provided by the PE in the AC cable. No additional ground is required.
Protection FunctionsIsolated Island, Voltage, Frequency, Temperature, Current etc.

**Specifications are subject to change without notice.**

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your micro inverter:

  • Cleaning: Periodically clean the exterior of the inverter to remove dust and debris. Ensure the inverter is disconnected from both DC and AC power before cleaning.
  • Inspection: Regularly inspect all cables and connections for any signs of wear, damage, or corrosion. Ensure all connections are tight.
  • Ventilation: Ensure the inverter's cooling fins are not obstructed to allow for proper heat dissipation.
  • Environmental Conditions: Verify that the inverter is not exposed to direct sunlight or rain, as per installation guidelines.

8. Troubleshooting

If you encounter issues with your micro inverter, refer to the LED indicator status and the following common problems:

  • No lights / Inverter not responding:
    - Check all DC and AC connections to ensure they are secure and correctly wired.
    - Verify that the solar panels are receiving sufficient sunlight.
    - Ensure the AC circuit breakers are ON.
  • Red light steady: This indicates a fault. Refer to the "LED Display Indicator" section for specific fault types (e.g., island protection, over-temperature, voltage/frequency issues). If the fault persists, contact support.
  • Red light flashing: The inverter is waiting. This is normal if there isn't enough solar power or if the grid is not yet stable.
  • Low Power Output:
    - Ensure solar panels are clean and free from shading.
    - Verify that the input voltage and power from the PV modules are within the inverter's specifications.
    - Check for proper cooling (see User Tips).
  • Crackling Sound: Some users have reported a crackling sound. According to the seller, this can be normal operation. If it's excessively loud or accompanied by other issues, contact support.

9. User Tips

Based on user experiences, here are some tips for optimizing your micro inverter's performance:

  • Cooling: The inverter can get quite hot, especially under constant high power output. Consider adding external cooling, such as a small computer fan, to help dissipate heat and maintain performance.
  • Internal Heat Pads: If comfortable with opening the device (and understanding potential warranty implications), some users have found success by ensuring the internal heat pads have good contact with the inverter's casing for better heat transfer.
  • Panel Matching: Ensure your solar panel's voltage and wattage are well-matched to the inverter's specifications to achieve optimal power conversion. Inverters may not always output the full rated power of the panels if there's a mismatch or suboptimal conditions.

10. Frequently Asked Questions (FAQ)

Q: Can this inverter be used with a 24-volt wind generator?
A: The GMI series micro inverters are specifically designed for solar photovoltaic (PV) modules with a DC input voltage range of 18-60V. Using it with a wind generator may not be compatible or efficient.
Q: My micro inverter has stopped lighting the green light; only the red one lights up. It hasn't even been a month of use yet.
A: A steady red light indicates a fault. Please refer to the "LED Display Indicator" section for possible causes like over-temperature, voltage/frequency issues, or island protection. Check all connections and ensure proper ventilation. If the issue persists, contact customer support.
Q: My inverter hasn't given any sign of life since the first test.
A: First, ensure all DC and AC connections are correctly made and secure. Verify that your solar panels are producing sufficient voltage and current, and that the AC grid is active and connected. Check all circuit breakers. If there's still no response, there might be a hardware issue.
Q: I connected it to a 49V 550W solar panel, but it never worked, not a single light, nothing at all. The power in Chile is 220V.
A: Ensure the inverter model you purchased is compatible with a 220V AC output (AC 180-280V models). Also, verify that the 49V DC input from your panel is within the inverter's operating voltage range (18-50V) and that the panel's power (550W) does not exceed the inverter's maximum input power. Double-check all connections and circuit breakers.

11. Warranty and Support

The Y&H GMI Series Micro Inverter comes with a 2-year warranty, ensuring protection against manufacturing defects and malfunctions under normal use. The product is CE compliant, indicating it meets European safety, health, and environmental protection requirements.

Shield icon representing multi-protection features and 2-year warranty.
Figure 6: Multi-Protection and Warranty Information

For detailed warranty terms, technical support, or to download the full user manual in PDF format, please refer to the official product documentation or contact Y&H customer service. A PDF user manual is available for download: User Manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.