NJTY 328D

Contents

NJTY 328D AC/DC Digital Clamp Meter

User Manual

1. Brief Introduction

The NJTY 328D is a multi-function digital clamp meter designed for high measurement accuracy, fast response, and a high safety level. It features a special chip capable of up to 6000 counts and a high-precision A/D converter with a high-speed digital processor for true RMS calculations up to AC 1KHz. This instrument provides accurate measurements, high resolution, and fast operation, with complete software calibration ensuring long-term accuracy.

This meter can be used to measure AC and DC voltage, AC and DC current, resistance, capacitance, temperature, diodes, and perform circuit continuity tests. It is equipped with a backlight for easy reading in dark environments.

NJTY 328D Clamp Meter with key features highlighted
Figure 1: NJTY 328D AC/DC Digital Clamp Meter highlighting True RMS, NCV, 100000uF capacitor testing, 6000 counts, and overload protection.

2. Safety Information

Please read and understand all safety information before operating this meter. Failure to follow these instructions could result in electric shock, fire, or serious injury.

  • This meter is rated for CAT II 600V and Pollution Grade 2.
  • The maximum voltage between the measurement end and ground is 600V.
  • Ensure the instrument is turned off and all test leads are disconnected before replacing batteries or fuses.
  • When measuring current, keep your fingers under the arc-shaped part of the clamp to ensure safety.
  • Observe correct polarity when connecting capacitors to protect the meter.
  • Do not attempt to measure voltages or currents exceeding the specified maximum ranges.
  • Overload protection is provided for various functions (e.g., 250V DC/AC for Resistance, Diode, DCA, ACA, Frequency, Capacitance).

3. Product Overview

The NJTY 328D clamp meter features a compact design with a large clamp jaw for easy testing. It includes a clear LED display and various function controls.

Dimensions of the NJTY 328D Clamp Meter
Figure 2: Dimensions of the NJTY 328D Clamp Meter (183mm L x 47mm W x 25mm H).
Hand holding the compact NJTY 328D Clamp Meter
Figure 3: The compact size of the NJTY 328D Clamp Meter for easy portability.
Close-up of the large clamp jaw (25mm opening)
Figure 4: The large 25mm clamp jaw for easier testing.

3.1. Symbols on Panel

Refer to the diagram below for an explanation of the symbols and controls on the meter's panel:

Diagram of NJTY 328D Clamp Meter panel with numbered components
Figure 5: Overview of the NJTY 328D Clamp Meter and its accessories.
  1. COM input socket
  2. LED display
  3. Clear symbol + frequency + percentage (ZERO+Hz+%) button: Press to clear DCA 60A readings or choose frequency/percentage in ACV/ACA ranges.
  4. True RMS indicator
  5. Trigger: Used to open and close the clamp.
  6. DCA direction symbol
  7. Clamp
  8. NCV induction plate
  9. NCV indicator
  10. Functions switch (Rotary Dial)
  11. Data hold (HOLD/*) button: Short press to hold data, long press to turn on/off backlight.
  12. Function choose (FUNC) button: Selects measurement functions.
  13. V/Ω/Hz/°C input socket

4. Setup

4.1. Initial Inspection

Upon receiving your NJTY 328D Clamp Meter, please check the package contents against the list below:

  • NJTY 328D Clamp Meter
  • Instruction Manual (this document and the included PDF)
  • Test Leads (one pair)
  • Thermocouple (one piece)
  • Instrument Case
  • AAA Batteries (two pieces, for initial installation)

If any items are missing or damaged, please contact your vendor immediately.

4.2. Battery Installation

The meter requires two AAA batteries for operation. Follow these steps to install them:

  1. Ensure the instrument is turned OFF.
  2. Pull all test pens out of the input sockets.
  3. Use a screwdriver to loosen the screws fixing the battery cover on the back of the meter.
  4. Remove the battery cover.
  5. Insert two new AAA batteries, observing the correct polarity (+/-).
  6. Replace the battery cover and tighten the screws securely.

5. Operation Instructions

5.1. General Operation

  • ZERO/Hz Key:
    • Clears induced digits on the LED screen when in DCA 60A range.
    • Used to choose frequency and percentage in ACV and ACA ranges.
  • FUNC Key: Used to select specific measuring functions (e.g., DCV/DCA, ACA modes, resistance, diode, buzzer, capacitance modes).
  • Data Hold (HOLD/*) Key:
    • Short press to enter/exit data hold mode.
    • Long press to turn on/off the backlight. The backlight automatically turns off after 15 seconds of no operation.
  • Auto Power Off: The meter will automatically turn off the LED screen after approximately 15 minutes of inactivity to save power. Any key press will restart it.

5.2. ACV and DCV Measurement

  1. Turn the rotary switch to the V position. Use the FUNC button to choose between AC (~) or DC (=) voltage measurement.
  2. Connect the black test lead to the COM jack and the red test lead to the V/Ω/Hz/°C jack.
  3. Measure the voltage of the circuit under test by touching the test leads to the desired points.

Note: The meter may show readings in DCV 600mV and 6V ranges even without input voltage or test leads connected. Short circuit V/Ω and COM to zero the meter. For AC voltage, the meter measures True RMS values.

5.3. Resistance Measurement

  1. Rotate the rotary switch to the Ω position. Press the FUNC button to select the 'Ω' resistance measurement mode.
  2. Connect the black test lead to the COM input socket and the red test lead to the V/Ω/Hz/°C input socket.
  3. Use the test leads to measure the resistance value of the circuit. The value will be shown on the display.

Notes:

  • To accurately measure low resistance, short-circuit the test leads to read their inherent resistance, then subtract this value from your measurement.
  • At 60 megohms range, the reading will stabilize after a few seconds.
  • If the display shows "OL" when not in circuit, it indicates the measurement value is out of range.

5.4. Diode Measurement

  1. Turn the rotary switch to the diode symbol (►|) position. Press the FUNC button to select the diode test mode.
  2. Connect the black test lead to the COM input socket and the red test lead to the V/Ω/Hz/°C input socket.
  3. Connect the black test lead to the negative electrode and the red test lead to the positive electrode of the diode under test.
  4. The meter will display the forward bias value. If polarity is reversed, it will show 'OL'.

5.5. Buzzer Test (Continuity)

  1. Turn the rotary switch to the buzzer symbol (🔊) position. Press the FUNC button to select the continuity test mode.
  2. Connect the black test lead to the COM input socket and the red test lead to the V/Ω/Hz/°C input socket.
  3. Measure the resistance of the circuit under test. If the resistance is less than approximately 50 Ω, the buzzer will sound continuously.

5.6. Capacitance Measurement

  1. Turn the rotary switch to the capacitance symbol (∔) position. Press the FUNC button to select the capacitance measurement mode.
  2. Connect the black test lead to the COM input socket and the red test lead to the V/Ω/Hz/°C input socket.
  3. Measure the capacitance value of the circuit under test. The reading will be shown on the display.

Notes:

  • Measuring large capacitors may take some time.
  • Ensure correct polarity when connecting capacitors to protect the meter.

5.7. Current Measurement (AC/DC)

  1. Turn the rotary switch to the 60A or 600A AC/DC current range. Press FUNC to choose between AC (~) or DC (=) current.
  2. Before testing DCA, press ZERO to clear any induced digits on the screen (only for 60A range). Induced digits in ACA will not affect results.
  3. Press the trigger to open the clamp jaw and clamp it around a single conductor under test. Read the current value on the LED display.

Notes:

  • Do not suddenly loosen the trigger to avoid reading changes.
  • Do not clamp two conductors with opposite current directions, as they will cancel each other out.
  • Keep fingers under the arc-shaped part of the clamp for safety.
  • If the display shows "OL", the input exceeds the selected range. Switch to a higher range.
  • In ACA testing mode, press the Hz key to test the frequency of the alternative current source (for currents greater than 20A).

5.8. Frequency Measurement

  1. Turn the rotary switch to the Hz% position.
  2. Connect the black test lead to the COM jack and the red test lead to the V/Ω/Hz/°C jack.
  3. Measure the frequency value of the circuit under test.
  4. Press FUNC to display frequency and duty cycle (0.1%–99.9%) respectively.

5.9. Temperature Measurement

  1. Turn the rotary switch to the °C (°F) position. The meter will show the surrounding temperature.
  2. Disconnect the test leads. Connect the thermocouple to the COM and V/Ω/Hz/°C inputs, observing correct polarity.
  3. The meter will display the approximate temperature from the thermocouple.

5.10. NCV (Non-Contact Voltage) Detection

The red LED on the upper right area of the panel will flash quickly when an electric field exceeding 20V is detected by the inductive sensor in the jaws, indicating the presence of voltage without physical contact.

NJTY 328D Clamp Meter demonstrating NCV electric field induction near an outlet
Figure 6: NCV electric field induction in action.
  1. Set the rotary function switch to the "NCV" position. The NCV indicator will flash every 1-2 seconds, signifying the instrument is ready.
  2. When the clamp jaws detect voltage, the NCV LED will flash rapidly.
NJTY 328D Clamp Meter with flashlight function active
Figure 7: Flashlight for emergency lighting use.

6. Maintenance

6.1. Battery Replacement

Refer to section 4.2 for detailed instructions on battery replacement. Always use two new AAA batteries and ensure correct polarity.

6.2. Cleaning

To clean the meter, wipe the case with a damp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the meter is completely dry before use.

7. Troubleshooting

  • "OL" Display: If the display shows "OL" (Overload), it indicates that the measured value exceeds the selected range. Switch to a higher range or ensure the circuit is within the meter's capabilities.
  • Low Voltage Display: A battery symbol (🔋) displayed on the screen indicates that the working voltage is low. Replace the batteries promptly to ensure accurate measurements.
  • No Display/Meter Not Turning On: Check if the batteries are installed correctly and are not depleted. Ensure the rotary switch is not in the "OFF" position.
  • Inaccurate Readings: Ensure test leads are properly connected and not damaged. Verify the correct function is selected for the measurement. For resistance, consider short-circuiting leads to check for inherent resistance.

8. Specifications

8.1. Comprehensive Indicators

  • Operating Conditions: 600V CAT II, Pollution Grade 2
  • Height: Under 2000m
  • Working Temperature: 0-40°C (<80%RH, not considered <10°C)
  • Storage Temperature: -10-60°C (<70%RH, remove battery)
  • Test/Calibrate Surrounding Temperature: 20°C ± 2°C
  • Max Voltage (Measurement End to Ground): 600V
  • Clamp Open Size: 25mm
  • Auto Ranging: Yes
  • Conversion Rate: Approx. 3s/second
  • Display: 6000 counts LED display
  • Overload Indication: 'OL' displayed
  • Low Voltage Indication: Battery symbol (🔋) displayed
  • Input Polarity Indicator: '-' shown automatically
  • Battery: 2 x AAA
  • Size: 183mm (L) * 47mm (W) * 25mm (H)
  • Weight: Approx. 165g (battery included)

8.2. Accuracy Index

Accuracy: ± (%reading + digit), one year warranty from the manufacture date. Conditions: surrounding temperature from 18°C to 28°C, <80%RH.

8.3. Measurement Ranges and Accuracy

Direct Current Voltage (DCV)
Range Resolution Accuracy
600mV0.1mV± (0.5% readings + 5 digits)
6V1mV
60V10mV
600V100mV± (0.8% readings + 5 digits)
Input resistance: 10MΩ, Max input voltage: DC600V
Alternative Current Voltage (ACV TRUE RMS)
Range Resolution Accuracy
6V1mV± (1% readings + 4 digits)
60V10mV
600V100mV± (1.2% readings + 10 digits)
Input resistance: 10MΩ, Max input voltage: 600V, Frequency response: 40Hz to 1KHz true RMS
Temperature
Range Resolution Scope Accuracy
°C1°C-20°C --- 1000°C± (1.0 + 3) readings
°F1°F-4°F --- 1832°F± (1.0 + 3) readings
Overload protection: 250V DC/AC, Open circuit voltage: 2.4V
Resistance
Range Resolution Accuracy
600Ω0.1Ω
6KΩ1Ω± (0.8% readings + 5 digits)
60KΩ10Ω
600KΩ100Ω
6MΩ1KΩ± (1.2% readings + 5 digits)
60MΩ10KΩ
Overload protection: 250V DC/AC
Diode and Buzzer
Function Test Conditions
Diode (►|)Displays approximate value of diode forward voltage drop.
Buzzer (🔊)Sounds when circuit resistance is lower than 50 Ω.
Overload protection: 250V DC/AC
Direct Current (DCA)
Range Resolution Accuracy
60A10mA± (3% readings + 3 digits)
600A100mA
Overload protection: 250V DC/AC
Alternative Current (ACA TRUE RMS)
Range Resolution Accuracy
60A10mA± (2.5% readings + 3 digits)
600A100mA
Overload protection: 250V DC/AC
Frequency
Range Resolution Accuracy
60Hz0.01Hz
600Hz0.1Hz± (1.5% readings + 5 digits)
6KHz0.001KHz
60KHz0.01KHz
600KHz0.1KHz
10MHz0.001MHz
Overload protection: 250V DC/AC, Input Voltage Range: 200mV --- 10V DC
Capacitance
Range Resolution Accuracy
60nF0.01nF
600nF0.1nF± (4.0% readings + 5 digits)
6uF1nF
60uF10nF
600uF100nF
6mF0.1uF± (5.0% readings + 5 digits)
100mF0.001mF
Overload protection: 250V DC/AC

9. User Tips

  • Always start with the highest range when measuring an unknown value to prevent overloading the meter.
  • For current measurements, ensure the clamp jaw completely encloses only one conductor. Measuring multiple conductors carrying current in different directions will result in an inaccurate reading.
  • Utilize the backlight feature in dimly lit areas by long-pressing the HOLD/* button.
  • Remember to turn off the meter when not in use to conserve battery life, although it has an auto-power-off function.
  • Keep the test leads and meter clean and free from dust or moisture for optimal performance.

10. Frequently Asked Questions (FAQ)

Q: Why does my meter show "OL"?
A: "OL" stands for Overload. It means the measured value is higher than the selected range. Try switching to a higher range setting.
Q: How do I know if the battery is low?
A: A battery symbol (🔋) will appear on the display when the battery voltage is low. Replace the batteries as soon as possible.
Q: Can I measure AC and DC current simultaneously?
A: No, you must select either AC or DC current mode using the FUNC button after setting the rotary switch to the current measurement range.
Q: What does True RMS mean?
A: True RMS (Root Mean Square) means the meter can accurately measure AC voltage and current for both pure sine waves and non-sine wave forms (like square waves, triangular waves, etc.), providing a more accurate reading than average-responding meters.

11. Warranty and Support

The NJTY 328D Digital Clamp Meter comes with a one-year warranty from the date of manufacture, covering defects in materials and workmanship under normal use. This warranty does not cover damage caused by misuse, accident, neglect, alteration, contamination, or abnormal operating conditions.

For detailed warranty terms, troubleshooting assistance, or technical support, please refer to the complete user manual PDF available at: NJTY 328D User Manual (PDF). You may also contact your point of purchase for further assistance.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.