1. Product Overview
The XB2-11BN series push button switches are industrial-grade momentary pushbuttons designed for panel-mount control applications. They feature a chrome-plated metal bezel, 22 mm mounting hole, and screw-terminal contact blocks compatible with Normally Open (NO), Normally Closed (NC), or combined configurations.
Model Variants & Color Codes
Available models and their distinguishing features:
| Model No. | Color | Marking | Description |
|---|---|---|---|
| XB2-11BN/R | Red | Plain | Stop / Emergency Stop |
| XB2-11BN/32 | Red | ● Symbol | Stop (IEC symbol) |
| XB2-11BN/G | Green | Plain | Start / Run |
| XB2-11BN/31 | Green | ✓ Symbol | Start (IEC symbol) |
| XB2-11BN/BL | Black | Plain | General purpose |
| XB2-11BN/35 | Black | ↓ Arrow | Down / Lower |
| XB2-11BN/34 | White | ↓ Arrow | Down / Lower |
| XB2-11BN/W | White | Plain | General purpose |
| XB2-11BN/Y | Yellow | Plain | Caution / Reset |
| XB2-11BN/B | Blue | Plain | General purpose |
| XB2-11BN/36 | Blue | ↑ Arrows | Up / Down |

2. Setup & Installation
- Step 1: Drill Mounting Hole
Drill a 22 mm diameter hole in the control panel where the switch will be mounted. - Step 2: Insert Button Body
Insert the button body from the front of the panel into the drilled hole. - Step 3: Secure with Locking Nut
Thread the locking nut onto the rear thread of the switch and tighten it firmly to secure the switch to the panel. - Step 4: Attach Contact Block
Attach the desired contact block (NO, NC, or combined) to the rear of the actuator. - Step 5: Connect Wiring
Proceed to connect the wiring as described in the 'Wiring Instructions' section. - Step 6: Verify Operation
Before applying full power, verify that the switch operates correctly.
Note: Panel thickness of 1-6 mm is recommended. The mounting torque for the locking nut should be approximately 1.2-1.5 N·m.

3. Wiring Instructions
3.1 1NO 1NC Wiring (Single Normally Open + Single Normally Closed)
- Terminal 1 & 2: NC contact (normally closed)
- Terminal 3 & 4: NO contact (normally open)
Connect the FireWire (Live / L) to terminal 1 (NC) or 3 (NO). Connect the load to terminal 2 or 4. The Zero line (Neutral / N) connects to the load's neutral terminal.
3.2 2NO / 2NC Wiring (Two Normally Open / Two Normally Closed)
- Upper Block (Terminals 3 & 4): First circuit
- Lower Block (Terminals 3 & 4): Second circuit
Both circuits share the same switching action.
IMPORTANT: Always de-energize the circuit before wiring. Do not exceed the rated voltage and current. Overtightening terminals may damage the contact block.


4. Operating Instructions
The XB2-11BN series push button switches are momentary devices, meaning they return to their default state when the button is released. The operation depends on the contact block configuration:
4.1 1NO + 1NC (Single Normally Open + Single Normally Closed)
- Default State: The green (NO) circuit is open; the red (NC) circuit is closed.
- Pushed State: The green (NO) circuit closes; the red (NC) circuit opens.
4.2 2NO (Two Normally Open)
- Default State: Both circuits (green) are open.
- Pushed State: Both circuits close simultaneously.
4.3 2NC (Two Normally Closed)
- Default State: Both circuits (red) are closed.
- Pushed State: Both circuits open simultaneously.
5. Maintenance & Safety Precautions
- Do not use in explosive atmospheres or corrosive environments.
- Do not exceed the rated electrical parameters (voltage and current).
- This product is not a safety-rated emergency stop device unless certified separately.
- Maintenance and replacement must be performed by qualified personnel.
- Disconnect power before cleaning; use a dry cloth only.
- Regularly inspect for contact wear, loose terminals, or mechanical damage.
6. Specifications
6.1 Technical Specifications
| Parameter | Value | Note |
|---|---|---|
| Rated Voltage | AC 240V / DC 24V | - |
| Rated Current | 3A (AC15) | IEC 60947-5-1 |
| Conventional Thermal Current (Ith) | 10A | - |
| Insulation Voltage (Ui) | 415V | - |
| Impulse Withstand Voltage (Uimp) | 6kV | - |
| Mounting Hole | 22 mm | Screw fixing |
| Contact Block Standard | GB/T 14048.5 | ZB2-BE101C |
| Actuator Action | Momentary (spring return) | - |
| Protection Class | IP40 (front panel) | - |
| Material | Alloy | - |
| Contact Resistance | ≤50mΩ | - |
| Electrical Insulation Resistance | ≥100mΩ | - |
6.2 Dimensions
| Dimension | Value | Note |
|---|---|---|
| Button head diameter | 28 mm | Overall width |
| Total height (with contact block) | 54 mm | - |
| Mounting hole | 22 mm | Panel cutout |
| Mounting method | Screw fixing | Panel thickness 1-6 mm |

7. User Tips
- Users have found these switches to be exactly as advertised, offering excellent value for money.
- The product generally meets expectations, indicating reliable performance.
8. Warranty & Support
This product is warranted against manufacturing defects for 12 months from the date of purchase under normal use conditions. The warranty does not cover damage caused by misuse, improper installation, or exceeding rated parameters.
9. Compliance & Standards
- IEC 60947-5-1: Low-voltage switchgear and controlgear — Control circuit devices
- GB/T 14048.5: Low-voltage switchgear and controlgear (Chinese national standard)
- CCC: China Compulsory Certification mark on contact block