1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the EARUELETRIC EAEMP3-100-TY-W 100A WiFi Smart Three Phase Energy Meter & Protector. This device is designed to monitor energy consumption and provide comprehensive protection against various electrical faults in three-phase systems.
2. Safety Information
Please read all safety warnings and instructions carefully before installation and operation to prevent electric shock, fire, or personal injury. Keep this manual for future reference.
- Installation should only be performed by qualified electricians.
- Ensure the power supply is completely disconnected before any installation or maintenance.
- Do not operate the device if it appears damaged.
- This product has no isolation function. Disconnect the front stage when repairing the circuit breaker switch.
- The zero line (N line) of this product is directly connected without a disconnection function.
- The protector must be wired according to the markings and connected correctly.
- Although this product has limited current protection function, it cannot replace circuit breakers. Install circuit breakers such as DZ47 or C65 at the front or the end of the line for short circuit protection.
- Before use, tighten the clamp screw to avoid product damage caused by poor connection.
3. Main Functions
The EAEMP3-100-TY-W offers a wide range of protective and monitoring features:

- Over Voltage Protection
- Under Voltage Protection
- Over Current Protection
- Under Current Protection
- Delay Protection
- Timer Switch
- Voltage Imbalance Protection
- Current Imbalance Protection
- Shortage Phase Protection
- Phase Sequence Protection
- High Temperature Protection
- Bidirectional Energy Monitor
Each parameter can be set with an action threshold and On/Off control.
4. Product Overview
The EAEMP3-100-TY-W is a compact, DIN rail-mountable device designed for smart energy management and protection.
4.1. Dimensions

- Height: 90mm (3.54in)
- Width: 77mm (3.03in)
- Depth: 76mm (2.9in)
- Mounting Depth: 35mm (1.38in)
- Overall Width (including terminals): 62mm (2.44in)
- Overall Height (including terminals): 45mm (1.77in)
4.2. Display and Indicators
The device features a clear display for real-time data and indicators for status:
- Backlight:
- The display will remain lit for 180 seconds without any actions.
- The backlight color is white during normal operation.
- It turns red when the relay is disconnected (e.g., during a power failure or protection trip).
- WiFi Indicator Status:
- Flashing rapidly: Searching for WiFi signal.
- Flashing slowly: WiFi is offline.
- Solid light: WiFi is connected.

5. Installation
5.1. Installation Conditions
- Temperature: -20℃ to 60℃
- Humidity: <85%
- Altitude: Not exceeding 2000m
- Pollution Level: Level 3
- Installation: 35MM DIN Rail
- Wiring Capacity: Insulated copper wire of 35 mm² or below.
5.2. Wiring Diagram
Refer to the markings on the device for correct wiring. Ensure all connections are secure and follow local electrical codes.
Note: A detailed wiring diagram is typically provided with the product. Please consult the official PDF user manual for specific wiring instructions. A PDF version of the user manual is available at this link.
6. Initial Setup
6.1. Power On
After successful wiring, switch on the power supply. The device display will light up, showing real-time voltage readings.
6.2. WiFi Pairing (Tuya App)
To enable smart features, connect the device to the Tuya Smart Life app:
- Ensure the device is powered on and the WiFi indicator is flashing rapidly (searching for signal). If not, long press the 'OK' button on the device to enter pairing mode.
- Open the Tuya Smart Life app on your mobile phone.
- Tap 'Add Device' or the '+' icon.
- The app may automatically discover the device. If not, select 'Electrical' -> 'Energy Meter' or 'Socket (Wi-Fi)'.
- Follow the on-screen prompts to enter your WiFi network details (2.4GHz network required).
- Confirm the device indicator is flashing as instructed by the app.
- The app will then attempt to connect to the device. Once connected, the WiFi indicator on the device will show a solid light.
7. Operating Instructions
7.1. Device Display Navigation
Use the up (▲) and down (▼) buttons on the device to switch and display various parameters:
- Real Time Current (A)
- Real Time Voltage (V)
- Real Time Power (W)
- Real Time Power Factor (cosφ)
- Real Time Frequency (Hz)
- Combined Reactive Energy Consumption (kVarh)
- Reactive Forward Energy Consumption (kVarh)
- Reactive Reverse Energy Consumption (kVarh)
- Reactive Phase A/B/C Energy Consumption (kVarh)
- Active Combined Energy Consumption (kWh)
- Active Forward Energy Consumption (kWh)
- Active Reverse Energy Consumption (kWh)
- Active A/B/C-Phase Energy Consumption (kWh)
7.2. Mobile App Control (Tuya Smart Life)
The Tuya Smart Life app provides comprehensive control and monitoring capabilities:

- View Various Data/Timing: Access total electricity consumption, current, voltage, power, and historical data.
- Expense Management: Enable prepayment, set balance energy (kWh), charge energy, view recharge records, and clear energy data.
- Scheduling: Set countdown timers, schedules (ON/OFF times for specific days), cycle timers (start/end durations), and inching (automatic turn-off after a period of operation).
- Alarm Settings: Configure thresholds and enable/disable alarms for various protections (see Section 8).
- Operation Records: View a log of device operations (e.g., open/close events).
8. Function Settings
Parameters can be configured directly on the device or via the Tuya Smart Life app. The app provides a more user-friendly interface for setting thresholds and enabling/disabling protection features.

8.1. On-Device Settings Navigation
- Enter Settings: Long press and hold the setting button (gear icon) to enter the setting status display page. The set data bits will flash.
- Adjust Value: Use the up (▲) and down (▼) buttons to set the content of the flashing bit.
- Switch Bit: Short press the setting button to move to the next setting bit.
- Confirm Page Settings: Short press 'OK' to confirm settings on the current page and jump to the next settings page.
- Exit & Save: Long press 'OK' to exit the setting state and save all settings.
- Restore Factory Configuration: From the 'Frequency Interface', long press the 'OK' button to restore factory settings.
8.2. Detailed Parameter Settings
| Function | Parameter Range | Default Setting | Description |
|---|---|---|---|
| Power Restoration Delay Protection | 0000-9999 Seconds (Hand Movement) | 5S | Protects the device from high voltage/surge during power restoration. 'Hand Movement' means Manual Recovery, '0000' means Immediate Recovery. |
| Over Voltage Limit | 60-300V | 275V | Device switches off if voltage exceeds this limit. Each phase can be set separately. |
| Under Voltage Limit | 60-300V | 175V | Device switches off if voltage drops below this limit. Each phase can be set separately. |
| Over/Under Voltage Protection Delay | 0000-9999 Seconds (Hand Movement) | 20S | Delay before device recovers after voltage returns to normal. |
| Under Current Limit | 0.0-60A | 0.0A | Device switches off if current drops below this limit after a delay. Each phase can be set separately. |
| Under Current Limit Delay Protection | 0000-9999 Seconds | 5S | Time delay before device switches off when current is under the setting value. |
| Under Current Limit Protection Delay | 0000-9999 Seconds | 20S | Time delay before device switches on when current recovers to be over the setting value. |
| Over Current Limit | 0.1-80A | 80A | Device switches off if current exceeds this limit after a delay. Each phase can be set separately. |
| Over Current Limit Delay Protection | 0000-9999 Seconds | 5S | Time delay before device switches off when current is over the setting value. |
| Over Current Limit Protection Delay | 0000-9999 Seconds | 60S | Time delay before device switches on when current recovers to be under the setting value. |
| Uneven Voltage Balance Protection % | On/Off 0000-9999% | On (Default 5%) | Device switches off if the highest or lowest voltage of ABC Phase exceeds the set value. |
| Current Unevenness Balance Protection % | On/Off 0000-9999% | On (Default 10%) | Device switches off if the highest or lowest current of ABC Phase exceeds the set value. |
| Phase Sequence Protection | On/Off | On | Device switches off if there is any phase error in the ABC phase sequence. |
9. User Tips
- The device's overcurrent and leakage current protection features have configurable tripping limits and delays via the Tuya app, offering flexible protection.
- While the device provides comprehensive data, the app's report graph may only show an aggregated graph and current values per phase, not individual phase power or energy.
- For optimal performance and longevity, ensure all wiring connections are tight and secure.
10. Troubleshooting
10.1. Common Issues
- WiFi LED always red or not flashing: This indicates a potential issue with the WiFi module or pairing process. Try re-entering pairing mode by long-pressing the 'OK' button. If the issue persists, the WiFi module might be faulty.
- Device malfunctioned after a few days: Check all wiring connections for tightness. Verify that the device is installed within the specified operating conditions (temperature, humidity). If the device is still under warranty, contact support.
- Factory-damaged goods: If the product arrived with physical damage or an open box, contact the seller immediately for a replacement.
10.2. Fault Record
The device records various fault events, including Overvoltage, Undervoltage, Overload, Low Current protection, Voltage Imbalance, Current Imbalance, and Phase Sequence Protection. These records can be viewed in the Tuya App under 'Alarm records' in the settings.
11. Specifications
| Parameter | Value |
|---|---|
| Model Number | EAEMP3-100-TY-W |
| Type | Mini Circuit breaker |
| Poles | 3P+N |
| Rated Current | 1-100A Adjustable |
| Rated Voltage | AC3*127V/240V or AC3*220V/415V (380V) |
| Rated Frequency | 50/60HZ |
| Breaking Capacity | 6kA |
| Tripping Curve | C Curve |
| Tripping Time | ≤0.1S |
| Mechanical Life | ≥80000 Cycles |
| Electric Life | ≥20000 Cycles |
| Is Smart Device | Yes (Tuya WiFi) |
| Certification | CE |
| Origin | Mainland China |
| Hign-concerned Chemical | None |
12. Maintenance
- Regularly check wiring connections for tightness to prevent poor contact.
- Keep the device clean and free from dust and moisture.
- Do not attempt to repair the device yourself. Refer to qualified personnel for service.
13. Warranty and Support
13.1. Guarantee
Within 12 months from the date of production, if there are any product quality issues and the seal is intact, the factory will provide free replacement. Within 36 months, if there are product quality issues and the seal is intact, the factory will provide free repair.
13.2. Contact Information
ZHEJIANG EARU ELECTRONICS CO.,LTD.
- Address: YAMING ROAD 38, XIANGYANG INDUSTRY AREA, LIUSHI TOWN, YUEQING CITY, ZHEJIANG PROVINCE, CHINA
- Website: https://cnoyou.en.alibaba.com/
- Manager: Bob Wu
- Email: bob@earuelec.com
- Phone Number: +86 15821639630
- WeChat ID: totybest-2
14. Frequently Asked Questions (FAQ)
- Q: Can it connect to a two-phase system and leave one line unconnected?
- A: The device is designed for 3P+N (three-phase plus neutral) systems. While it might function with two phases and neutral, its full protective and monitoring capabilities for a three-phase system may not be utilized or accurate. It's recommended to use it as intended for optimal performance and safety.
- Q: Does this have automatic re-ignition if the power cuts off and comes back on?
- A: The device has a 'Power Restoration Delay Protection' function. This protects the device from instantaneous high voltage and surge during power restoration. The default delay is 5 seconds, but it can be configured for manual recovery or immediate recovery (0000 seconds) via settings.
- Q: Can I install it in the main energy panel to protect the entire residence?
- A: Yes, it can be installed in the main energy panel. However, remember that this product has limited current protection and cannot replace dedicated circuit breakers. Always install appropriate circuit breakers (like DZ47 or C65) at the front or end of the line for short circuit protection, as per safety guidelines.