1. Introduction
The ATORCH AT085 is a high-performance Type-C tester designed for precise measurement and display of real-time electrical parameters. This device allows users to monitor voltage, current, power, energy, and capacity for various USB-C compatible devices. Featuring support for multiple fast charging protocols, a G-Sensor for screen rotation, and peak recording capabilities, the AT085 is an essential tool for evaluating the performance of chargers, power banks, and other Type-C digital devices.
2. Safety Information
- Ensure the device is used within its specified voltage and current limits to prevent damage to the tester or connected equipment.
- Avoid exposing the device to extreme temperatures, humidity, or corrosive environments.
- Do not attempt to disassemble or modify the device, as this will void the warranty and may cause malfunction or injury.
- Keep the device away from water and other liquids.
- Handle with care to prevent physical damage.
3. Product Overview
The ATORCH AT085 Type-C Tester features a compact design with a clear digital display and intuitive button controls. It is housed in a durable silvery metal shell with plastic components.

Figure 1: ATORCH AT085 Type-C Tester displaying real-time measurements.
Interface Function Diagram

Figure 2: Interface and button layout of the ATORCH AT085.
- C Male input/output: Connects to the power source (e.g., charger, power bank).
- C Female input/output: Connects to the device being charged/tested (e.g., mobile phone, laptop).
- Data display area: Shows various electrical parameters.
- Up/In/Back button: Used for navigation and settings.
- Down/Zero/Confirm button: Used for navigation, resetting values, and confirmation.
4. Specifications
| Parameter | Value |
|---|---|
| Brand Name | ATORCH |
| Model Number | AT085 |
| Working Voltage | DC 4.5~50V |
| Working Current | 0~6A (Instant peak value 12A) |
| Measure Power | 0~600W |
| Measure Electric Energy | 0~9999Wh |
| Measure Capacity | 0~99999mAh |
| Self Power Consumption | <0.15W |
| Sampling Resistor | 0.001R |
| Data Retention Period | 20 years (at TA=55°C) |
| Operating Temperature | -10~60°C (typical 0~45°C / 32~113°F) |
| Accuracy Class | 1% (Software calibration technique) |
| Power Supply | USB DC Power |
| Display Type | Digital Only, Color Screen |
| Screen Size | 0.85 inch |
| Backlight Brightness Adjustment | Yes |
| G-Sensor | Yes (for screen rotation) |
| Screen Rotation Operation Mode | Key operation |
| Screen Shutdown Function | Yes |
| Button Mode | Double key button |
| Peak Recording | Current, voltage, and power Peak recording |
| Dimensions | 43mm*25mm*10mm |
| Housing | Silvery Metal shell+plastic |
| Certification | CE |
5. Setup
The ATORCH AT085 is designed for simple plug-and-play operation.
- Connect the C Male input/output port of the AT085 to your Type-C power source (e.g., wall charger, power bank, computer USB-C port).
- Connect the C Female input/output port of the AT085 to the Type-C device you wish to test or charge (e.g., smartphone, tablet, laptop).
- The device will automatically power on and begin displaying measurements.
Important Notice:
When using a USB-C port charger, the meter will only light up for display when both the charger and the mobile phone (or other load) are connected simultaneously. This is because most Type-C chargers default to no voltage output until a load protocol is detected.
6. Operating Instructions
Functional Operation
- Up/In/Back button:
- Short press: Scrolls up through display pages or adjusts values in settings.
- Long press: Enters settings menu or returns from a function.
- Warm tip: When pressing and holding this button on the first two display pages, the screen display will turn black and white.
- Down/Zero/Confirm button:
- Short press: Scrolls down through display pages or adjusts values in settings.
- Long press (on different pages): Selects capacity Zero, pauses the curve display, confirms selections, or zeros no-load current.
- Warm tip: Quickly press this key five times to lock or unlock the screen display direction (G-Sensor rotation).
Display Modes and Features
The AT085 offers various display modes and features to monitor your devices effectively.

Figure 3: Real-time voltage and current curve display.
Real-time Voltage Current Curve Display: The device can show real-time voltage and current fluctuations during the charging process, allowing for detailed analysis of stability and performance. This feature is particularly useful for engineers to observe the curve status over time.

Figure 4: Compatibility with PD3.1 and various fast charging protocols.
Fast Charging Protocol Support: The AT085 is compatible with future PD3.1 48V high-voltage protocol and covers almost all protocol power-on tests of the C port, including PD2.0, PD3.0, PPS, QC2.0, QC3.0, FCP, SCP, AFC, PE, DASH VOOC, and SuperVOOC.

Figure 5: Real-time peak recording of Voltage, Current, and Power.
Real-time Peak Recording: The device includes a function to record the maximum test data (voltage, current, power) during the charging process. This allows users to easily identify the maximum charging power of a connected device without constant monitoring.

Figure 6: Testing various Type-C digital devices.
Versatile Testing: The AT085 can be used to test a wide range of Type-C digital devices, providing valuable insights into their charging behavior.

Figure 7: Built-in DC-DC switching power supply for low self-power consumption.
Low Self Power Consumption: The AT085 incorporates a high-cost DC-DC switching power supply chip, ensuring wide input voltage range, high power supply efficiency, low power consumption, low loss, and low heat generation.

Figure 8: Summary of AT085 key features.
7. Maintenance
- Keep the device clean by wiping it with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Avoid dropping or subjecting the device to strong impacts.
- Regularly check the Type-C ports for any debris or damage that might affect connectivity.
8. Troubleshooting
Frequently Asked Questions
- Question 1: Why does the product not display when plugged into the charger separately?
- Answer: The Type-C port of most chargers defaults to no voltage output until a load protocol is detected. At this time, the product has no power supply and will not display. The charger will only have voltage output when a load (e.g., mobile phone) is connected, and the product will only display readings at that time. Ensure both the charger and the device being charged are connected to the tester.
- Question 2: Why can't the test meter measure 10A or 120W on my product charger?
- Answer: The values tested by this product are real-time charging parameters during the charging process. The parameters marked on the charger (e.g., 10A or 120W) represent the maximum theoretical power capabilities of the charger, not necessarily the actual output at all times. The real-time output depends on the connected device's power requirements and the charging protocol negotiated. The AT085 displays the actual power being delivered.
- Question 3: Why occasionally does the display show a current of 0.01-0.02A when the output is not connected to a load?
- Answer: This product uses bidirectional current detection. A small no-load current reading (0.01-0.02A) is a normal phenomenon due to the sensitivity of the measurement circuit. This can often be reset by quickly pressing the current reset interface button five times.
9. User Tips
- The AT085 has been successfully tested with high-power devices like MacBook Pro, handling up to 100W, demonstrating its robust performance.
- While the display is clear and colorful, some users might find it a little small. Utilize the display modes to switch between detailed information (smaller font) and summary information (larger font) for better readability.
- The device features buttons on the side that allow you to cycle through different screens and select the display language (English/Chinese).
- The default display is in color, but you have the option to switch to a black and white display if preferred.
- The AT085 is a standalone device and does not typically require external software for Windows monitoring.
10. Warranty and Support
For warranty information, technical support, or further assistance, please refer to the official product documentation or contact the seller directly. A detailed user manual in PDF format may be available for download at this link.