1. Introduction
Thank you for choosing the YJCAL DF2604D Series Wire Connectors. These quick electric universal connectors are designed for efficient and secure splicing of various wire types, suitable for LED cables, general electrical connections, and more. This manual provides essential information for safe operation, installation, and maintenance of your wire connectors.
2. Important Safety Instructions
Operation
- Open the handle to 90°.
- The stripping length of the wire is 10-12mm.
- Insert into the hole.
- Put down the handle.
WARNING
- Please ensure the power supply is completely disconnected before wiring. Do not operate while live to prevent the risk of electric shock.
- Only applicable to circuits within the rated voltage and current range. Refer to the product casing for specific parameters. Overloading may cause fires or equipment damage.
- Avoid installing this product in damp, dusty, or flammable/explosive environments. It is only suitable for indoor use in dry, non-corrosive gas conditions.
- The stripping length of the wire must strictly match the terminal requirements, as being too long or too short may result in poor contact or arcing.
- Do not disassemble or modify this product; non-professional operation may damage the insulation performance and cause safety hazards.
- Keep out of reach of children.
CE Compliance
This product meets the CE marking requirements of the EU market and complies with the EU Low Voltage Directive (2014/35/EU) and Electromagnetic Compatibility Directive (2014/30/EU).
References to the relevant harmonised standards used or references to the other technical specifications in relation to which conformity is declared:
- EN 60998-1:2004, EN IEC 61000-3-2:2019+A1:2021
- EN 61000-3-3:2013+A1:2019+A2:2021
- EN IEC 61000-6-1:2019, EN IEC 61000-6-3:2021
CE
3. Product Overview
Components and Types
The DF2604D series offers various configurations to suit different wiring needs:
- DF2604D-1P: 1 input, 1 output
- DF2604D-2PC: 2 input, 2 output
- DF2604D-3P: 3 input, 3 output
- DF2604D-4P: 4 input, 4 output
- DF2604D-5P: 5 input, 5 output

Key Features
- Booster Design: Ensures a firm fix for electric wires, with easy opening and closing.
- Wide Wire Range: Accommodates 0.2-4.0mm² hard wire and 0.14-4.0mm² flexible cord.
- Flame Retardant Material: Shell made from flame retardant PA66 nylon, resistant to corrosion, aging, high temperatures, and provides strong insulation.
- Pure Copper Guide: Features a 0.8mm thick red copper conductor for excellent electrical conductivity, strong oxidation resistance, and corrosion resistance.
- Stainless Steel Circlip: Ensures secure wire retention.
- Removable Unlimited Splicing: Connectors can be easily joined and separated to extend or modify connections.
- Applicable Wire Types: Suitable for BV Single strand hard conductor, BVR Multi strand hard conductor, and RV Multi strand flexible conductor.



4. Specifications
| Parameter | Value |
|---|---|
| Model | DF2604D Series |
| Rated Voltage | 250V |
| Rated Current | 32A |
| Shell Material | Flame Retardant PA66 (Nylon) |
| Connection Material | Copper (Red Copper Conductor) |
| Spring Material | Stainless Steel |
| Wire Range (Hard Wire) | 0.2 - 4.0 mm² |
| Wire Range (Flexible Cord) | 0.14 - 4.0 mm² |
| Stripping Length | Around 10 mm |
| EU LVD Voltage | Below 50Vac or 75Vdc |
| Certification | CE |
Dimensions (Approximate)
- DF2604D-1P: L 7mm x W 43.6mm x H 15.2mm
- DF2604D-2PC: L 12.5mm x W 43.5mm x H 15mm
- DF2604D-3P: L 18.8mm x W 43.5mm x H 15mm
- DF2604D-4P: L 23.6mm x W 43.5mm x H 15mm
- DF2604D-5P: L 29.8mm x W 43.5mm x H 15mm

5. Setup and Installation
Follow these steps for proper wire connection:
- Prepare the Wire: Carefully peel off the wire insulation for approximately 10mm. Ensure the stripped part is clean and free from damage.
- Open the Connector: Open the booster (handle) of the terminal block to a 90-degree angle.
- Insert the Wire: Insert the stripped end of the wire completely into the terminal hole. Ensure no bare wire is exposed outside the connector.
- Secure the Connection: Push the booster (handle) down firmly until it locks into place, securing the wire.
- Splicing (Optional): For multi-connector splicing, align the connectors and push them together until they click into place.


6. Operating Instructions
The DF2604D connectors are designed for simple and reliable operation:
- Connecting Wires: Follow the setup instructions to connect individual wires securely.
- Unlimited Splicing: Multiple connectors can be joined together to create longer or more complex wiring configurations. Simply align the connectors and push them together.
- Butt Plug Type: For long-distance wiring, the wires on both sides can be connected separately. Then, carry out the misalignment and insert to complete the wiring.
- Disassembly: To remove a wire, open the booster (handle) to release the wire. To separate spliced connectors, gently pull them apart.


7. Maintenance
YJCAL DF2604D wire connectors are designed for durability and require minimal maintenance:
- Keep Dry: Ensure connectors are used and stored in dry conditions to prevent corrosion.
- Cleanliness: Keep connectors free from dust, dirt, and debris. Use a dry cloth to wipe them if necessary.
- Inspection: Periodically inspect connections for any signs of damage, loose wires, or discoloration. Replace any damaged connectors immediately.
8. Troubleshooting
If you encounter issues with your wire connectors, consider the following:
- Loose Connection: If a wire feels loose or power is intermittent, ensure the wire was stripped to the correct length (10-12mm) and fully inserted into the terminal block before the booster was closed. Re-insert the wire if necessary.
- No Power: Check the entire circuit for continuity. Ensure all connections are secure and that the wires are properly seated in the connectors. Verify that the wire gauge is within the specified range for the connector.
- Overheating: If connectors show signs of overheating (melting, discoloration), immediately disconnect power. This could indicate an overload or a poor connection. Ensure the current does not exceed the rated 32A.
9. Warranty and Support
For any questions, technical assistance, or support regarding your YJCAL DF2604D wire connectors, please contact your seller or the point of purchase. Please have your product model number (DF2604D) available when seeking support.