NJTY T400A, T600A, T400, T600

Contents

NJTY Infrared Thermometer User Manual

Models: T400A, T600A, T400, T600

1. Introduction

This infrared thermometer is designed for non-contact measurement of surface temperatures. It is suitable for various applications involving hot, hazardous, or hard-to-reach objects, allowing for safe and quick temperature readings.

The device offers quick measurement in just 0.5 seconds, features laser positioning for accurate targeting, and provides an audio-visual alert with backlight. It is switchable between Celsius and Fahrenheit and includes a low voltage indicator and automatic shutdown function.

NJTY Infrared Thermometer in hand, highlighting key features like quick measurement, laser positioning, and C/F switch.
NJTY Infrared Thermometer highlighting its quick response, laser targeting, and unit conversion.
NJTY T600 Infrared Thermometer with features: single laser point, audio-visual dual alarm, measurement range -58 to 1112 degrees Fahrenheit, automatic shutdown, non-adjustable emissivity.
Features of the T600 model, including laser point, alarm, and measurement range.

2. Safety Warnings & Cautions

2.1. Warnings

To prevent potential harm to people or damage to the device, please observe the following:

  • Before use, carefully inspect the plastic housing. Do not use if there is any damage.
  • Do not point the laser directly at eyes or indirectly off reflective surfaces.
  • Do not use this unit in environments with explosive gas, steam, or excessive dust.

2.2. Cautions

To avoid damage to the unit or the target, protect it from the following conditions:

  • Electromagnetic fields (EMF) from arc welders or induction heaters.
  • Thermal shock caused by large or abrupt ambient temperature changes. Allow 30 minutes for the unit to stabilize before use.
  • Do not leave the unit on or near objects of high temperature.
Side view of the infrared thermometer showing a laser warning label.
Laser warning label on the side of the device.

3. Setup

3.1. Battery Installation

The thermometer requires two 1.5V AAA batteries (not included). To install:

  1. Open the battery compartment. Use a screwdriver to rotate the switch knob to the 'OPEN' position.
  2. Insert two 1.5V AAA batteries, ensuring correct polarity.
  3. Close the battery compartment by rotating the switch knob to the 'LOCK' position.
Diagram showing the battery compartment of the infrared thermometer with 'LOCK' and 'OPEN' positions.
Battery compartment with lock/open mechanism.
Infrared thermometer in its packaging next to the instruction manual.
Product packaging showing the thermometer and manual.

4. Operating Instructions

4.1. Distance to Spot Size (D:S Ratio)

When taking measurements, pay attention to the Distance to Spot (D:S) ratio. As the distance (D) from the thermometer to the target surface increases, the spot diameter (S) on the target surface becomes larger. The D:S ratio for this device is approximately 12:1.

Scope of Observation: Ensure that the measured target is larger than the measuring area. For smaller targets, bring the infrared thermometer closer. To measure accurately, the target should be at least twice as large as the measuring area.

Diagram illustrating the Distance to Spot (D:S) ratio of 12:1 for the infrared thermometer.
Distance to Spot (D:S) ratio diagram.

4.2. Basic Measurement

The device features a clear LCD display with various indicators:

Diagram of the thermometer's display and buttons, labeled A through J for different functions.
Thermometer display and button indications.
  • A. HOLD: When performing a single measurement and releasing the trigger (1), this symbol appears, indicating the current temperature value is held.
  • B. SCAN: During continuous measurement while holding the trigger, this symbol indicates continuous measurement. The temperature value is displayed at position 'G'. The maximum temperature value during continuous measurement is displayed at 'J'.
  • C. Laser Point: Press key (2) to toggle the laser pointer on/off. The laser is for aiming only.
  • D. Backlight: Press key (4) to toggle the LCD backlight on/off.
  • E. Power: Battery capacity indicator.
  • F. Temperature Unit: Press key (3) to switch between Celsius (°C) and Fahrenheit (°F).
  • G. Temperature Value: The current measured temperature.
  • H. Emissivity Symbol: Indicates the emissivity setting.
  • I. Max Symbol: Indicates the maximum temperature.
  • J. Max Temperature Value or Emissivity: Long press key (3) to display the preset emissivity (0.95). Press key (2) or key (4) to adjust emissivity, then press key (3) to save.

4.3. Single Measurement

  1. Point the thermometer at the target.
  2. Pull and release the trigger. The laser point will activate to help aim.
  3. The temperature of the target will be displayed on the LCD.
Infrared thermometer measuring the temperature of water in a kettle.
Measuring water temperature with the thermometer.

4.4. Continuous Measurement

  1. Pull and hold the trigger.
  2. Slowly move the thermometer across the target area.
  3. The thermometer will continuously scan and display the temperature on the LCD. The maximum temperature value during continuous measurement will also be displayed.
Infrared thermometer measuring the temperature of water in a glass.
Measuring water temperature in a glass.
Infrared thermometer measuring the temperature of pet food in a bowl.
Measuring pet food temperature.
Close-up of the thermometer display showing a temperature of 23.7 degrees Celsius.
Display showing a temperature reading.
Thermometer display showing 23.2 degrees Celsius with backlight activated.
Display with backlight activated.

5. Maintenance

5.1. Lens Cleaning

  1. Use compressed air to blow away any loose debris.
  2. Gently wipe away residual small debris with a camel hair brush.
  3. Carefully wipe the lens surface with a wet cotton cloth.

5.2. Shell Cleaning

Use a sponge or soft cloth with soap and water to clean the device's shell.

6. Troubleshooting

  • No Display: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • Inaccurate Readings: Ensure the D:S ratio is appropriate for the target size and distance. Allow the device to stabilize for 30 minutes if there have been abrupt ambient temperature changes. Check and adjust emissivity for specific materials if your model supports it.
  • Laser Not Working: Ensure the laser point function is activated (press key 2).
  • Display Invisible at Angle: Some users report the screen can be invisible at certain angles. Try adjusting your viewing angle.

7. Specifications

Please note that specifications may vary slightly between models (T400A, T600A, T400, T600).

Feature Details
Temperature Range -50~400°C (-58~752°F) or -50~600°C (-58~1112°F)
Emissivity 0.95 Preset, Adjustable from 0.01 to 1.00 (for T600A) / 0.95 Preset, Unadjustable (for T600)
Accuracy ≥0°C (32°F): ±1.5°C (±2.7°F) or ±1.5% (take maximum)
<0°C (32°F): ±3°C (±5.4°F) or ±3% (take maximum)
Spectral Response 8-14µm
Resolution 1% of reading or 1°C
Response Time 500mSec, 95% response
Distance to Spot Rate 12:1
Max Value Display Yes (for T600A) / No (for T600)
Operating Temperature 0~50°C (32~122°F)
Operating Humidity 10-90%RH non-condensing
Storage Temperature -20~60°C (-4~140°F) Without Batteries
Power 2 x 1.5V AAA Batteries

7.1. Emissivity Table for Common Materials

Different materials have different emissivity values. For more accurate measurements, especially with models that allow adjustment, refer to the table below and adjust the emissivity accordingly.

Material Emissivity Material Emissivity Material Emissivity
Aluminum0.30Iron0.70Asbestos0.95
Brick0.50Bituminous0.95Limestone0.98
Basalt0.70Oil0.94Brass0.50
Paint0.93Brick0.90Paper0.95
Carbon0.85Plastic0.95Ceramics0.95
Rubber0.95Concrete0.95Sand0.90
Copper0.95Skin0.98Oil Sludge0.94
Snow0.90Frozen Items0.90Steel0.80
Hot Food0.93Textile0.94Glass0.85
Water0.93Ice0.98Wood0.94

8. User Tips

  • Accuracy: For optimal accuracy, especially with smaller objects, measure from a closer distance (e.g., about 20cm from the measurement point). The device is generally reported to be 98-99% accurate.
  • Batteries: Remember that the thermometer requires two AAA batteries, which are typically not included in the package.
  • Emissivity Adjustment (T600A and similar models): If you have a model like the T600A that allows emissivity adjustment, utilize this feature for more precise readings on different materials such as aluminum or steel.
  • Water Temperature: This thermometer is suitable for measuring water temperature, making it useful for tasks like checking tank temperatures or baking.
  • Versatile Use: Users find it effective for various applications, including checking temperatures in reptile enclosures, spider enclosures, and general kitchen use.

9. Warranty & Support

For detailed warranty information and further support, please refer to the official user manual PDF. A digital version of the user manual is available at: NJTY Infrared Thermometer User Manual (PDF).

This manual provides comprehensive instructions and specifications for your device.

© 2024 NJTY. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.