1. Introduction
This infrared thermometer is designed for non-contact surface temperature measurement. It is suitable for various hot, hazardous, or hard-to-reach objects, providing safe and quick temperature readings.

Image: NJTY T600A Infrared Thermometer in use, highlighting features like 0.5-second rapid response, laser positioning, audio-visual alert, switchable Celsius/Fahrenheit, AAA battery requirement, and low voltage indication.
2. Safety Warnings and Cautions
2.1. Warnings
- Before use, carefully check the plastic housing for any damage. Do not use if damaged.
- Do not point the laser directly at eyes or indirectly off reflective surfaces.
- Do not use this unit in environments with explosive gas, steam, or dust.
2.2. Cautions
- Protect the unit from Electro-Magnetic Fields (EMF) generated by arc welders or induction heaters.
- Avoid thermal shock: If the unit experiences large or abrupt ambient temperature changes, allow 30 minutes for it to stabilize before use.
- Do not leave the unit on or near objects of high temperature.
3. Setup
3.1. Battery Installation
- Open the battery compartment.
- Insert two 1.5V AAA batteries, ensuring correct polarity.
- Close the battery compartment.

Image: Diagram from the instruction manual. The left section illustrates the battery compartment and its switch knob. Use a screwdriver to rotate the switch knob to open/lock the compartment.
4. Operating Instructions
4.1. Distance to Spot Size Ratio
When taking measurements, pay attention to the Distance to Spot (D) ratio. As the distance from the thermometer to the target surface increases, the spot diameter (S) on the target surface becomes larger. The Distance to Spot ratio for this device is approximately 12:1.
Refer to the bottom-right diagram in the manual image above, which illustrates the relationship between distance (D) and spot size (S), with examples of spot diameters at various distances (e.g., 1.0" at 12", 3.0" at 36", 5.0" at 60").
4.2. Scope of Observation
Ensure that the measured target is larger than the measuring area. For smaller targets, bring the infrared thermometer closer. For accurate measurements, the target should be at least twice as large as the measuring area.
4.3. Display Indications
The LCD display provides various indications:
- A. HOLD: Appears when a single measurement is taken, indicating the current temperature value is held on screen.
- B. SCAN: Appears during continuous measurement, indicating the thermometer is actively measuring.
- E. Power: Battery capacity indicator.
- G. Temperature Value: Displays the current temperature.
- I. MAX Symbol: Indicates the maximum temperature value.
- J. Max Temperature Value: Displays the maximum temperature recorded during continuous measurement.
Refer to the top-right diagram in the manual image above, which shows the thermometer's LCD display, labeling various indicators such as HOLD, SCAN, battery capacity, temperature value, and MAX symbol.
4.4. Measurement Modes
- Single Measurement: Pull and release the trigger. The laser point will activate for aiming. The temperature of the target will be displayed on the LCD.
- Continuous Measurement: Pull and hold the trigger. Slowly move the thermometer across the target surface. The thermometer will continuously scan and display the temperature, including the maximum temperature value, on the LCD.
4.5. Button Functions
The device features several buttons for control:
- Key (2) (Laser Point): Press to turn the laser point on or off. The laser is for aiming only.
- Key (4) (Backlight): Press to turn the LCD backlight on or off.
- Key (3) (Temperature Unit / Emissivity):
- Short press to switch between Celsius (°C) and Fahrenheit (°F).
- Long press to access emissivity adjustment (for T600A model). The preset emissivity is 0.95. Use Key (2) or Key (4) to increase or decrease the emissivity, then press Key (3) again to save.

Image: The thermometer display showing temperature readings in both Celsius and Fahrenheit, demonstrating the switchable measurement feature.
5. Maintenance
5.1. Lens Cleaning
- Use compressed air to blow away any loose debris.
- Gently wipe away residual small debris with a camel hair brush.
- Carefully wipe the surface with a wet cotton cloth.
5.2. Shell Cleaning
Use a sponge or soft cloth with soap and water to clean the device's shell.
6. Specifications
This manual covers general specifications for multiple models. The T600A model features adjustable emissivity.

Image: NJTY T600A Infrared Thermometer, emphasizing its features such as single laser point indicator, audio-visual dual prompt alarm, measurement range (-58 to 1112 degrees Fahrenheit), automatic shutdown, and adjustable emissivity.
| Feature | Description |
|---|---|
| Brand Name | NJTY |
| Model | T600A (Adjustable Emissivity) |
| Theory | Multifunctional Infrared Thermometer |
| Max Measuring Temperature | 120°C & Above |
| Temperature Range | -50°C to 600°C (-58°F to 1112°F) |
| Accuracy | ±1.5°C (±2.7°F) for >0°C (32°F); ±3°C (±5.4°F) for <0°C (32°F) |
| Emissivity | 0.95 Preset, Adjustable from 0.01 to 1.00 (T600A) |
| Spectral Response | 8-14µm |
| Resolution | 1% of reading or 1°C |
| Response Time | 500mSec, 95% response |
| Distance to Spot Rate | 12:1 |
| Operating Temperature | 0°C to 50°C (32°F to 122°F) |
| Operating Humidity | 10-90% RH non-condensing |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) (Without Batteries) |
| Power | 2 x 1.5V AAA Batteries |
6.1. Emissivity Parallel Table
Different materials have different emissivity. For more accurate values, especially with the T600A model, adjust the emissivity setting.
| Material | Emissivity | Material | Emissivity | Material | Emissivity |
|---|---|---|---|---|---|
| Aluminum | 0.30 | Iron | 0.70 | Asbestos | 0.95 |
| Bituminous | 0.95 | Limestone | 0.98 | Basalt | 0.70 |
| Brass | 0.50 | Paint | 0.93 | Brick | 0.90 |
| Carbon | 0.85 | Plastic | 0.95 | Ceramics | 0.95 |
| Concrete | 0.95 | Sand | 0.90 | Copper | 0.95 |
| Oil sludge | 0.94 | Snow | 0.90 | Frozen items | 0.90 |
| Hot food | 0.93 | Textile | 0.94 | Glass | 0.85 |
| Ice | 0.98 | Wood | 0.94 | Steel | 0.80 |
| Water | 0.93 | Skin | 0.98 |
7. Troubleshooting
If the thermometer is not functioning as expected, consider the following:
- No Display / Low Power: Check battery installation and replace with fresh 1.5V AAA batteries if needed. The device has a low voltage indication and automatic shutdown feature.
- Inaccurate Readings:
- Ensure the target is larger than the measurement spot.
- Verify the emissivity setting (for T600A model) matches the material being measured. Refer to the Emissivity Parallel Table in Section 6.1.
- Allow 30 minutes for the unit to stabilize if it has experienced a sudden change in ambient temperature (thermal shock).
- Clean the lens as per maintenance instructions.
- Laser Not Working: Press Key (2) to ensure the laser point is turned on.
- Backlight Not Working: Press Key (4) to ensure the backlight is turned on.
If issues persist, consult the full user manual available as a PDF: NJTY Infrared Thermometer User Manual (PDF).
8. User Tips

Image: A side-by-side comparison of the NJTY T600 (fixed emissivity) and T600A (adjustable emissivity) models, showing their similar appearance but highlighting the T600A's advanced features.
- Accuracy: Users have noted good accuracy, typically within 1 degree. For best results, ensure proper emissivity settings for the material being measured.
- Versatility: This thermometer is suitable for a wide range of applications, including water temperature, baking, kitchen use, and industrial settings.
- T600 vs T600A: The T600A model offers adjustable emissivity, which is beneficial for measuring various materials more accurately compared to the T600 model with fixed emissivity.
9. Frequently Asked Questions (FAQ)
Q: What is the difference between T600 and T600A?
A: The T600A model features adjustable emissivity, allowing for more precise temperature measurements across different materials. The T600 model has a fixed emissivity.
Q: What is the maximum temperature this device can measure?
A: The device can measure temperatures up to 600°C (1112°F).
10. Warranty and Support
Information regarding specific warranty terms and customer support contact details is not provided in the available documentation. Please refer to the seller or product packaging for warranty information.