1. Product Overview

The LZJV Silicone Aquarium Oxygen Pump Hose is a versatile and durable accessory designed for various aquatic applications, including freshwater and seawater fish tanks, aquaculture, and live transportation. Made from food-grade silicone material, this hose ensures safety and reliability for your aquatic environment. Its flexible and transparent design allows for easy installation and monitoring of airflow.

Coiled transparent silicone hose
Image 1: Coiled transparent silicone hose.

2. Safety Warnings

Please read these safety warnings carefully before using the product to ensure safe operation and prevent damage.

  1. Prevent Siphon Backflow: The outlet of the air pipe must be positioned higher than the water level in the tank, or a check valve must be installed. This prevents water from flowing back into the air pump and causing damage.
  2. Child and Pet Safety: Keep the oxygen pump hose and all related accessories out of reach of children and pets to avoid the risk of tracheal entanglement or accidental ingestion.

3. Specifications

Feature Detail
Material Food Grade Silicone
Inner Diameter 4mm
Outer Diameter 6mm
Color Transparent
Available Lengths 1m, 3m, 5m, 10m, 20m
Battery Included No
Hign-concerned Chemical None
Power (W) None (Passive component)
Close-up of silicone hose showing 4mm inner diameter and 6mm outer diameter
Image 2: Close-up view of the hose indicating inner (4mm) and outer (6mm) diameters.

4. Installation

  1. Connect the Trachea:
    • Connect one end of the silicone hose (trachea) securely to the air pump outlet. Ensure a tight fit to prevent air leakage.
    • Connect the other end of the hose to the intake end of a check valve. The arrow on the check valve should point towards the bubble stone.
    • Connect the outlet end of the check valve to the bubble stone or air disc.

    Key Tip:

    • The check valve must be installed higher than the water surface.
    • Ensure the arrow on the check valve points upwards, indicating the correct direction of airflow towards the aquarium.
  2. Place the Oxygenation Terminal:
    • If using a bubble stone: Sink it to the bottom of the aquarium and fix its position using a suction cup (if provided).
    • If using an air tray: Place it flat on the bottom substrate, ensuring it is not covered by decorations that could obstruct airflow.
  3. Fix the Trachea: Use suction cups or fixing clips to secure the hose along the aquarium wall. This prevents bending or folding, which could affect airflow.
  4. Multi-channel Diversion (Optional): If you need to connect multiple air stones, use a three-way valve. This allows you to divert the gas pipe and adjust the air volume for each branch using the valve.

5. Operating Instructions

  1. Start-up: Connect the air pump to power. Confirm there is no water or air leakage at any connection points. Adjust the air pump volume knob slowly, increasing from the minimum setting.
  2. Gas Volume Regulation: Observe the bubble density. For small fish tanks, microbubble flow is recommended. For larger fish tanks, the airflow can be increased as needed. For silent operation, lowering the air volume at night can reduce noise levels.
  3. Closing Sequence: Turn off the air pump power first, then unplug the hose from the air pump (if necessary) to prevent water from flowing back.

6. Maintenance and Upkeep

Cycle Operation
Daily Check if the bubbles are evenly distributed and if there are any creases in the hose.
Weekly Clean Bubble Stones: Gently brush any surface algae with an old toothbrush and soak the bubble stone in clean water.
Monthly Check the check valve: Blow forcefully through it to test for one-way patency.
Every 3 Months Replace the hose (if aging or cracking) and bubble stone (if pores are blocked).

7. Troubleshooting

Fault Phenomenon Cause Solution
No bubbles
  • Hose bend/blockage
  • Bubble stone blockage
  • Reverse installation of check valve
  • Straighten out the hose
  • Clean/replace gas stone
  • Reinstall check valve correctly
Weakened airflow Air pipe joint leaks Cut off the aging pipe head and re-insert it tightly.
Water poured back into the hose Check valve fails or is not installed
  • Power off immediately.
  • Disassemble the pump body to dry.
  • Install/replace check valve.

8. User Tips

  • Users have noted the tubing is sturdy, flexible, and stretchable, making it easy to work with during installation.
  • The transparent texture allows for easy visual inspection of airflow and potential blockages.
  • Ensure to select the correct length (1m, 3m, 5m, 10m, 20m) for your specific aquarium setup to avoid unnecessary connections or excess tubing.
  • This product is specifically designed for 4mm inner diameter and 6mm outer diameter connections. It is not compatible with 1/2 inch tubing.

9. Warranty & Support

For specific warranty information and customer support, please refer to the seller or the official product page. A detailed user manual in PDF format is also available for download:

View User Manual (PDF)

For any issues not covered in this manual, please contact the seller's customer service for assistance.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.