Introduction
The ATORCH DT20W is a versatile DC power detector designed for measuring and displaying parameters such as voltage, current, power, and electrical capacity. It is suitable for various DC power sources, batteries, or battery packs, including lithium batteries, lithium iron phosphate, lead-acid, and nickel-hydrogen batteries, with working voltages ranging from 0 to 420V.
This device features a high-definition color screen and multiple interfaces for comprehensive data monitoring and system configuration. It also supports WiFi connectivity for remote monitoring via the Tuya or Smart Life app.

ATORCH DT20W Smart DC Battery Capacity Detection Tester with WiFi connectivity and mobile app interface.
Setup Instructions
Important Note on Capacity Measurement:
This meter does not immediately display the capacity of the connected battery when first powered on. For accurate capacity measurement, it is necessary to fully charge the battery first. Then, connect it to this meter and press and hold the plus (+) and minus (-) buttons simultaneously to clear the meter's accumulated capacity to zero. Subsequently, discharge the battery through this meter until it runs out of charge. The accumulated measured capacity during this discharge will represent the storage capacity of the tested battery.
Wiring Instructions (0-420V DC)
The DT20W uses a true four-wire wiring method. It is crucial to follow the wiring diagrams precisely. The device requires an independent DC 5V power supply (e.g., via USB Type-C).
General Wiring (Excluding Relays)
This diagram illustrates the standard connection without an external relay. The device itself must be powered by an independent DC 5V supply.

General wiring diagram for the DT20W, showing connections for battery (B+, B-), load/power supply (P+, C-), voltage sampling, and the 5V USB power supply for the instrument. The WiFi module and temperature probe are optional.
- Sampler Connection: The bidirectional current sampler must be connected in series to the negative electrode (B-) circuit of the battery pack. The P-end of the sampler should be connected to the negative electrode P-/C- for charging and discharging. Do NOT connect the sampler to the positive circuit.
- Voltage Sampling: Use one red and one black wire to connect the positive and negative terminals of the battery to the voltage sampling input interface as shown in the diagram. These are ordinary thin wires.
- Device Power Supply: Connect the provided Type-C data cable to a 5V USB power supply to power the product. The display should then activate normally.
- Current Flow Principle: Ensure that all current flowing through the battery passes through the bidirectional current sampler.
Warning: The current line passing through the load should be as thick as possible and meet the required carrying current of the load. Thicker wire diameter improves performance and safety.
Wiring with Relays for Power-Off Function
To achieve automatic power-off protection for overvoltage, undervoltage, or overpower, an additional relay can be integrated into the circuit. This relay must be purchased separately.

Wiring diagram for the DT20W including an external relay to achieve power-off function. The relay requires its own independent DC 5V power supply.
Connect the relay according to the diagram. The relay can support automatic power-off protection during battery testing when fully charged and fully discharged, as well as automatic power-off protection for overvoltage, overcharge, and overdischarge during power testing. This is useful for testing various batteries, power adapters, constant current loads, and power banks.
Notice: The relay requires an independent DC 5V power supply. After connecting the relay, the DC 5V will be inserted into the HID interface, and the relay will function.
Connecting to Tuya or Smart Life App
The DT20W supports remote monitoring and control via the Tuya Smart or Smart Life mobile applications.

Step-by-step guide for adding the DT20W device to the Tuya Smart app.
- Download and install either the Tuya Smart or Smart Life app on your mobile device and register an account.
- Power the DT20W device using a DC USB 5V power supply. The product's connection light will flash, indicating it has entered pairing mode.
- Open the Tuya Smart or Smart Life app on your mobile device and follow the on-screen instructions to add a new device. You will typically select 'Add Device' and then 'Auto Scan' or manually select the device type. Enter your 2.4GHz Wi-Fi network password when prompted.
Operating Instructions
Initial Power-On and Language Selection
Upon successful power-on, the device will prompt for language selection.
Video demonstrating initial power-on, language selection, and interface navigation of the DT20W.
- Once powered, the device will display a 'Language selection' menu.
- Use the 'Power' (+) or 'Connect' (-) buttons to navigate between 'English' and '中文' (Chinese).
- Press the 'M/OK' button to confirm your selection. This will lead you to the main testing interface.
Interface Navigation
The DT20W features several display interfaces to show different data sets. You can switch between these interfaces using the navigation buttons.
- Switching Interfaces: Short press the 'Power' (+) or 'Connect' (-) buttons to cycle through different testing interfaces.
- Main Interface: Displays real-time voltage (Vol), current (Cur), power (Pwr), resistance (Res), accumulated energy (Ene), and accumulated capacity (Cap), along with battery percentage.
- Alarm Interface: Shows overvoltage (OVT), low voltage (LVT), and overpower (OPT) thresholds.
- Percentage Interface: Provides a visual representation of battery capacity.
- Curve Interface: Displays voltage, power, energy, and CPU temperature curves over time.
- Large Font Display Interface: Offers a simplified view with larger text for key parameters.
- HID/Bluetooth/WiFi Online Interfaces: Indicate connection status for data communication.
System Settings
To access advanced settings and calibration options, enter the system settings menu.
- Enter Settings: Long press the 'M/OK' button to enter the background settings menu.
- Navigate Settings: Use the 'Power' (+) or 'Connect' (-) buttons to scroll through the menu options.
- Select/Confirm: Short press 'M/OK' to select an option or confirm a change.
- Exit: Select 'Exit' from the menu or long press 'M/OK' again to return to the main interface.
Key settings include:
- Language Style: Change display language.
- Display Brightness: Adjust screen brightness.
- Standby Brightness: Adjust brightness in standby mode.
- Enter Standby Time: Configure idle time before entering standby.
- Diverter size: Set the current shunt rating (e.g., 100A, 200A, 400A).
- Ext_temp Calibration: Calibrate external temperature probe readings.
- Voltage Calibrate Ref: Calibrate voltage readings for accuracy.
- Current Calibrate Ref: Calibrate current readings for accuracy.
- Overvoltage Prompt: Set the overvoltage alarm threshold.
- Lowvoltage Prompt: Set the low voltage alarm threshold.
- Overpower Prompt: Set the overpower alarm threshold.
- Over_Temp Ext.T: Set external over-temperature alarm threshold.
- Zero No-Load Current: Calibrate zero current reading when no load is present.
- HID/WIFI/Bluetooth: Manage connectivity options.
- Zero All Data: Reset all accumulated data (capacity, energy, etc.).
- Default Setting: Restore factory default settings.
- Mini Measure Amp: Adjust minimum current measurement.
Specifications
| Feature | Specification |
|---|---|
| Brand Name | ATORCH |
| Model Number | DT20W |
| DIY Supplies | Electrical |
| Voltage Range | DC 0-420V (DC5V independent power supply for device) |
| Measurement Voltage Range | DC0-420V |
| Current Range (Optional) | 0~30A / 0.1~100A / 0.2~200A / 0.3~300A / 0.4~400A / 0.5~500A / 0.6~600A |
| Measurement Current Range | 0.1-100A / 0.2-200A / 0.3-300A / 0.4-400A / 0.5-500A / 0.6-600A |
| Measurement Power Range | 0-42KW / 84KW / 126KW / 168KW / 210KW / 252KW (depending on current shunt) |
| Capacity Range | 0-99999AH |
| Operating Temperature | -20°C ~ +60°C |
| Power Supply | DC (5V independent power supply for the device) |
| Display Type | Analog and Digital |
| Certification | CE |
| Support WIFI | Yes |
| Battery Included | No |
| High-concerned Chemical | None |
| Origin | Mainland China |
Maintenance
Calibration
For optimal accuracy, the DT20W allows for calibration of voltage and current readings. This can be done through the 'System Settings' menu by adjusting 'Voltage Calibrate Ref' and 'Current Calibrate Ref'. It is recommended to use a known accurate reference meter for calibration.
Cleaning
To clean the device, gently wipe the screen and casing with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the display or housing.
Troubleshooting
- Inaccurate Capacity Reading: If the capacity reading seems incorrect, ensure you have followed the initial capacity reset procedure (fully charge, zero all data, then fully discharge). The device accumulates capacity, so for accurate State of Charge (SOC), the reset procedure is crucial.
- Device Powers Off/On Repeatedly: Check the stability of the independent 5V DC power supply connected to the device. An unstable power source can cause intermittent operation.
- Wi-Fi Connectivity Issues: If the Wi-Fi connection is lost or unstable, try re-pairing the device with the Tuya/Smart Life app. Ensure your Wi-Fi router is operating on a 2.4GHz band and is within range. If issues persist, check for app updates or contact support.
- Screen Not Displaying: If the device connects to a PC but the screen remains blank, check the 'Display Brightness' setting in the 'System Settings' menu. It might be set too low.
- Overheating: When operating at high currents, the shunt can generate heat. If the device experiences overheating, consider adding active cooling (e.g., a small fan) to prevent damage to components.
- General Issues: If you are a novice user or encounter complex issues, refer to the detailed user manual (PDF) or contact the manufacturer's technical personnel for assistance.
User Tips
- Capacity Adjustment: Users have reported success in changing the battery capacity value in the 'System Settings' menu (e.g., setting 22, depending on firmware version) to match their battery's actual capacity.
- Cost-Effective Monitoring: The DT20W is praised for its accuracy and cost-effectiveness, making it a popular choice for monitoring various power systems, including solar setups.
- Easy Wi-Fi Setup: Many users find the Wi-Fi setup with the Tuya Smart or Smart Life app to be quick and straightforward.
- Remote Monitoring & Automation: With the Tuya/Smart Life app, you can remotely monitor voltages, currents, and power from anywhere. You can also create smart routines or scenes (e.g., trigger an event if voltage drops below a certain threshold) and integrate with platforms like Home Assistant.
- Versatile Battery Compatibility: The device is suitable for a wide range of battery types, including LiFePo4, lead-acid, AGM, and GEL batteries.
- Calibration for Precision: Take advantage of the voltage and current calibration features in the system settings to fine-tune the meter's readings to match a reference instrument.
- Included Accessories: The product typically includes a USB Type-C cable and an NTC temperature probe, which are useful for setup and monitoring.
- Solar Panel Monitoring: The DT20W can be effectively used as a wattmeter to calculate energy from solar panels, provided the voltage and current are within the device's specified ranges (e.g., up to 400V and various current options).
Additional Resources
A detailed user manual in PDF format is available for download, providing more in-depth instructions and diagrams:
Warranty and Support
For warranty information, technical support, or any product-related inquiries, please refer to the documentation provided with your purchase or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.