Thank you for choosing the QUICK Hot Air Heat Gun Rework Station. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your 857DW+ or 957DW+ unit. Please read this manual thoroughly before using the device to ensure proper function and to prevent damage.

QUICK 857DW+ and 957DW+ Hot Air Rework Stations

Figure 1: QUICK 857DW+ (left) and 957DW+ (right) Hot Air Rework Stations.

2. Safety & Warnings

Read all instructions before use to ensure safety and prevent damage.

  • Warning: Keep the device and its power cord out of reach of children under 3 years old.
  • Always wear protective eyewear when operating the rework station.
  • Ensure adequate ventilation in your work area to prevent inhalation of flux fumes.
  • Do not touch the hot air nozzle or heated components directly during or immediately after operation. Allow them to cool down.
  • Ensure the rework station is properly grounded to prevent static electricity damage to sensitive electronic components.
  • Do not operate the device in damp or wet conditions.
  • Turn off the power and unplug the unit from the mains before cleaning or maintenance.

3. Package Contents

Please check the package for the following items:

QUICK 957DW+ package contents

Figure 2: QUICK 957DW+ package contents.

  1. Packaging Box
  2. Instructions for Use (this manual)
  3. Mainframe (Rework Station Unit)
  4. Hot Air Nozzles (3 for 957DW+, 4 for 857DW+)
  5. Air Gun Support Bracket
  6. Hot Air Gun Handle

4. Setup

  1. Placement: Place the rework station on a stable, heat-resistant, and level surface.
  2. Power Connection: Connect the power cord to the back of the mainframe and then plug it into a suitable 220V AC power outlet.
  3. Nozzle Installation: Select the appropriate hot air nozzle for your task. Align the nozzle with the hot air gun's outlet and secure it. Ensure it is firmly attached to prevent air leakage or detachment during operation.

Video 1: Demonstration of nozzle mounting, temperature and air volume adjustment, automatic sleep function, and hot air desoldering.

5. Operating Instructions

  1. Power On: Flip the 'POWER' switch on the front panel to the 'ON' position. The LED display will illuminate.
  2. Temperature Regulation: Turn the 'TEMP CONTROL' knob to set the desired temperature. The LED display will show the set temperature. The temperature range is typically 100-450°C.
  3. Air Volume Regulation: Turn the 'AIR CONTROL' knob to adjust the airflow intensity. Start with a lower setting and increase as needed for your application.
  4. Automatic Sleep Function: When you place the hot air gun handle onto its designated support bracket, the unit will automatically enter sleep mode. The air pump will continue to supply air until the temperature drops to 100°C, then it will fully enter sleep state (display shows '----'). When you pick up the handle again, the unit will automatically resume operation and heat up to the previously set temperature.
  5. Application: Direct the hot air stream onto the component or area to be worked on. The hot air gun is suitable for heat shrinking, drying, paint removal, adhesive removal, defrosting, preheating, disinfection, and glue welding.
Hot air gun in use on a circuit board

Figure 3: Hot air gun in use on a circuit board, illustrating applications like heat shrinking, drying, paint/adhesive removal, defrosting, preheating, disinfection, and glue welding.

Close-up of QUICK 957DW+ display and control knobs

Figure 4: Close-up of QUICK 957DW+ display and control knobs, showing temperature setting and sleep state indicator.

Side view of the rework station demonstrating automatic sleep function

Figure 5: Side view of the rework station demonstrating the automatic sleep function when the handle is placed on the bracket.

6. Maintenance

6.1 Nozzle Maintenance

  • Cleaning: Regularly clean the hot air nozzles to prevent residue buildup. Use a dedicated brass wool or a soft, lint-free cloth when the nozzle is cool. Never use files or sandpaper to mechanically clean the nozzle.
  • Preventing Damage: Avoid dry-heating the nozzles for extended periods at excessively high temperatures, as this can accelerate wear.
  • Replacement: Hot air nozzles are consumable parts. Replace them if they become deformed, clogged, or show significant wear that affects performance.

6.2 Unit Maintenance

  • Cleaning: Turn off the device and unplug it before cleaning. Use a soft, lint-free cloth to wipe down the exterior of the mainframe. Do not use abrasive cleaners or solvents.
  • Storage: Store the rework station in a dry place at room temperature (15°C - 35°C).
  • Long-term Storage: If the unit will not be used for an extended period, ensure it is clean and stored in a protective manner to prevent dust accumulation.

7. Troubleshooting

If you encounter issues with your rework station, please check the following:

  • No Power: Ensure the power cord is securely plugged into both the unit and the wall outlet. Check the power switch is in the 'ON' position. Verify the power outlet is functional.
  • No Heat/Insufficient Heat: Check the temperature setting. Ensure the hot air gun handle is properly seated in its support if it was in sleep mode. Allow sufficient time for the unit to reach the set temperature.
  • No Airflow/Weak Airflow: Check the 'AIR CONTROL' knob setting. Ensure the nozzle is not clogged.
  • Display Errors: If the display shows unusual characters or no reading, power off the unit, wait a few minutes, and power it back on. If the issue persists, contact support.

For problems not listed here, please consult the official support channels.

8. Specifications

Specification table for QUICK 857DW+ and 957DW+

Figure 6: Detailed specification table for QUICK 857DW+ and 957DW+ models.

Feature857DW+957DW+
Operating VoltageAC 220V/50Hz
Product Power580W
Display TypeLED digital tube (resolution 1 °C)
Temperature Range100-450 °C
Flow Rate50L/min (Max)
Air Flow TypeStraight flow
Heating Core ModelA1147
Air Ducts Length0.85m
Power Cord Length1.3m1.0m
Standard Air Nozzle3/6.3/8.3/12mm (One each)3/6.3/8.3mm (One each)

8.1 Product Dimensions

Product dimensions diagram for both 857DW+ and 957DW+

Figure 7: Product dimensions diagram for both 857DW+ and 957DW+ models.

9. User Tips

  • Always allow the unit to complete its cool-down cycle (sleep mode) before powering off completely to prolong the life of the heating element.
  • Use the smallest effective nozzle size for precise work to avoid damaging surrounding components.
  • Practice on scrap circuit boards to get a feel for temperature and airflow settings before working on valuable electronics.
  • Keep your workspace clean and organized to prevent accidental damage or short circuits.

10. Disposal & Recycling

This symbol indicates that this product should not be treated as household waste. According to the WEEE Directive (2012/19/EU), it must be disposed of at an appropriate electronic waste collection point for recycling. This helps prevent potential negative consequences for the environment and human health that could arise from improper waste disposal.

11. Warranty & Support

For warranty information, technical support, or service inquiries, please refer to the seller's contact information or the official QUICK website. Keep your purchase receipt as proof of purchase.

© 2024 QUICK. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.