DATOUBOSS DN-022 / DN-023 (1200W / 1500W)

Contents

DATOUBOSS Pure Sine Wave Inverter User Manual

Models: DN-022 (1200W Continuous) / DN-023 (1500W Continuous)

Introduction

Thank you for choosing the DATOUBOSS Pure Sine Wave Inverter. This device is designed to convert 12V DC power from your battery into stable 220V-240V AC power, suitable for a wide range of household appliances and electronic devices. Featuring advanced MCU microprocessor-controlled SPWM technology, it delivers a pure sine wave output, ensuring compatibility and safe operation for sensitive electronics. This manual provides essential information for the safe and efficient use of your inverter.

DATOUBOSS Pure Sine Wave Inverter showing LCD screen, USB port, and EU socket

Figure 1: DATOUBOSS Pure Sine Wave Inverter (DN-022/DN-023)

Product Features

  • Pure Sine Wave Output: Utilizes MCU microprocessor-controlled SPWM technology for a pure sine wave output, ensuring compatibility with all types of loads, including sensitive electronics.
  • Dynamic Current Loop Control: Advanced technology for reliable and stable inverter operation.
  • Strong Load Adaptability: Capable of handling various load types including inductive (e.g., motors, refrigerators), capacitive (e.g., power supplies), resistive (e.g., heaters), and mixed loads.
  • Comprehensive Protection Functions: Built-in safeguards against input over-voltage, under-voltage, overload, overheat, and output short circuit.
  • Intelligent LCD Display: Provides real-time status information at a glance.
  • Efficient Cooling: Features a built-in air-cooled system with a smart fan and temperature control for optimal performance and longevity.
  • High Conversion Efficiency: Achieves a work efficiency of 80% to 95%, minimizing energy loss from the battery.
  • Robust Design: Single-channel multi-group transformer series innovation reduces copper and magnetic loss, heat, and improves overall efficiency.
  • Dual Current Detection: Front and back stage current detection provides multiple protections, ensuring stable operation and preventing damage from single electronic component failure.
Intelligent LCD display showing battery capacity, voltage, output frequency, power, and load capacity, along with protection icons.

Figure 2: Intelligent LCD Display and Protection Features

Setup Instructions

1. Installation Requirements

  1. Environment: Ensure the installation area is dry, clean, and well-ventilated.
  2. Working Temperature: The inverter is designed to operate within a temperature range of -20°C to 80°C.
  3. Battery Connection: Always connect the inverter to a battery of matching voltage (12V DC).
  4. Cabling: Use only the original connecting cables provided with the inverter to ensure proper and safe operation.
  5. Ventilation: Do not cover the inverter or block its ventilation openings. Adequate airflow is crucial for heat dissipation.

2. Component Identification

Labeled diagram of the inverter's external features: Switch, USB, European plugs, Negative terminal, Fan, Positive terminal, LCD display.

Figure 3: Inverter External Features

  • Switch: ON/OFF power switch.
  • USB Port: 5V 1.2A USB output for charging small devices.
  • European Plugs (AC-OUTPUT): Standard EU AC output socket.
  • Negative Terminal (-): Black terminal for negative battery connection.
  • Positive Terminal (+): Red terminal for positive battery connection.
  • Fan: Cooling fan for heat dissipation.
  • LCD Display: Digital screen showing operational status.

3. Battery Compatibility

This inverter is suitable for use with 12V lead-acid batteries (AGM, GEL, FLD) and Lithium Iron Phosphate (Li-on) batteries.

Icons representing AGM, GEL, FLD, and Li-on batteries, indicating compatibility with 12V lead-acid and lithium iron phosphate batteries.

Figure 4: Compatible Battery Types

4. Connecting the Inverter to a Battery

Follow these steps to safely connect your inverter to a 12V DC battery:

  1. Ensure the inverter's power switch is in the "OFF" position.
  2. Connect the red cable (positive) from the inverter's positive terminal (+) to the positive terminal of your 12V battery.
  3. Connect the black cable (negative) from the inverter's negative terminal (-) to the negative terminal of your 12V battery.
  4. Ensure all connections are tight and secure to prevent arcing or poor performance.
Play video
Watch video online

Video 1: Demonstrating the correct battery connection for the inverter. Connect the red cable to the positive terminal and the black cable to the negative terminal of a 10-15V battery.

Operating Instructions

1. Powering On and Off

  1. After connecting the battery, switch the inverter's ON/OFF button to the "ON" position.
  2. The LCD display will illuminate, showing the current status.
  3. To power off, switch the ON/OFF button to the "OFF" position.
Play video
Watch video online

Video 2: Demonstrating how to turn the inverter ON/OFF using the front panel switch.

2. Understanding the LCD Display

The LCD display provides critical information about the inverter's operation and status:

  • Battery Capacity: Indicates the remaining charge in your battery.
  • Battery Voltage (DC): Shows the current input voltage from the battery.
  • Output Frequency: Displays the AC output frequency (50Hz/60Hz).
  • Output Power (W): Shows the current power consumption of connected loads.
  • Load Capacity: Visual representation of the load percentage.
  • Protection Indicators: Icons or messages will appear for various protection states (e.g., Low Voltage, High Voltage, Overtemperature, Overload, Short Circuit).

3. Connecting AC Loads

Plug your AC appliances directly into the European AC output socket on the inverter. Ensure the total continuous power consumption of your appliances does not exceed the inverter's rated continuous power (1200W for DN-022, 1500W for DN-023) and that surge power does not exceed the peak power (2500W for 1200W model, 3000W for 1500W model).

4. Using the USB Port

The USB port provides a 5V 1.2A output for charging compatible USB devices. Note that the USB port is only active when the inverter is switched ON.

Maintenance and Safety Precautions

  • Professional Installation: Installation and commissioning of this equipment should be carried out by professional electrical maintenance personnel who are familiar with the structure of the unit and the dangers of operation.
  • Keep Dry: Keep the inverter away from water. Avoid any liquid dripping onto the machine.
  • Handle with Care: Do not plug or unplug the inverter with wet hands.
  • Flammable Substances: Keep the inverter away from flammable substances or places where flammable gases are piled up.
  • High Voltage Warning: High voltage is dangerous. Do not open the inverter casing or attempt to repair it yourself.
  • Switch Off When Not in Use: Always switch off the inverter when it is not in use to conserve battery power and for safety.
  • Cleaning: Regularly clean the exterior of the inverter with a dry, soft cloth. Ensure ventilation openings are free from dust and debris.

Troubleshooting

The inverter is equipped with multiple protection features. If the inverter stops working or displays an error, check the following:

  • No Output / Inverter Not Turning On:
    • Check battery connections: Ensure positive and negative terminals are correctly and securely connected.
    • Check battery voltage: If the battery voltage is too low (below 10V), the inverter will enter low-voltage protection mode. Recharge or replace the battery.
    • Check inverter switch: Ensure the ON/OFF switch is in the "ON" position.
  • Inverter Shuts Down / Overload Protection:
    • Reduce load: The total power consumption of connected appliances may exceed the inverter's continuous or peak power rating. Disconnect some appliances.
    • Check for short circuit: A fault in the electrical appliance or load circuit can trigger short-circuit protection. Disconnect all loads and try powering on the inverter. If it works, test appliances one by one.
  • Inverter Shuts Down / Overheat Protection:
    • Ensure proper ventilation: Check that the inverter's cooling fan is not blocked and that there is sufficient airflow around the unit.
    • Reduce ambient temperature: Operate the inverter in a cooler environment if possible.
    • Reduce load: Continuous high loads can cause overheating.
  • Inverter Turns Off and On Periodically:
    • This often indicates a marginal condition, such as the battery voltage being near the low-voltage protection threshold or the load being close to the overload limit. The inverter might be cycling between normal operation and protection mode. Address the underlying issue (e.g., charge battery, reduce load).
  • Fan Noise:
    • The inverter features a temperature-controlled smart fan. The fan speed will increase with higher loads and internal temperature to dissipate heat. While normal, some users find it noisy at higher loads. This is generally expected behavior for efficient cooling.

Specifications

FeatureDN-022 (1200W)DN-023 (1500W)
Product ModelDN-022DN-023
Continuous Output Power1200W1500W
Peak Power2500W3000W
DisplayLCD liquid crystal display
Input VoltageDC 12V
Input Range12V (10-15V)
Output VoltageAC 220V±10% / 230V (50Hz/60Hz)
Output Frequency50Hz/60Hz
Output WaveformPure sine wave
Low Voltage Protection10V
Overvoltage Protection15V
No-load Current0.7A0.8A
Overheating Protection80°C ± 5°C
Conversion Efficiency≥90%
Cooling MethodBuilt-in air-cooled
Overall Dimension31 x 12 x 6.4 cm
Product Weight1.9kg2.3kg
CertificationsCE, FCC, pse
Diagram showing the inverter's dimensions and heat dissipation fan features.

Figure 5: Inverter Dimensions and Cooling System

User Tips

Based on user experiences, here are some helpful tips for optimizing your inverter's performance:

  • Quiet Operation: At low loads, the fan operates quietly or may even turn off, contributing to a less noisy environment.
  • Peak Load Handling: The inverter can handle short bursts of high power (peak power) for appliances like coffee machines or refrigerators starting up. However, avoid sustained operation above the continuous rated power.
  • Battery Efficiency: The high conversion efficiency (up to 95%) helps conserve battery power, extending the operational time of your devices.
  • Battery Choice: For best performance and longevity, consider using high-quality LiFePO4 batteries.
  • Terminal Compatibility: Be aware that the inverter's terminals might be M6, while some battery cables come with M8 terminals. Ensure compatibility or use appropriate adapters.
  • USB Port Functionality: The USB charging port is only active when the main inverter function is switched ON.
  • Fan Noise at High Loads: Expect the cooling fan to become noticeably louder when the inverter is under heavy load, as it works to dissipate heat.

Warranty and Support

For detailed warranty information, please refer to the official product documentation or contact the seller directly.

A comprehensive user manual in PDF format is available for download:

Download User Manual (PDF)

For further assistance or inquiries, you may contact support via:

  • Mobile/WeChat/Whatsapp/LINE: +8613783531376
  • Email: Manager@xdatou.com
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.