Gaqqee LCR-TC1

Contents

LCR-TC1 Multi-function Tester User Manual

Model: LCR-TC1

1. Introduction

The Gaqqee LCR-TC1 is a versatile multi-function tester designed for quick and accurate identification and measurement of various electronic components. Featuring a 1.8-inch TFT LCD display, it can test transistors, diodes, triodes, capacitors, resistors, and inductors, providing essential parameters for each component.

LCR-TC1 Multi-function Tester with accessories

Figure 1: LCR-TC1 Multi-function Tester with included accessories (USB cables, test leads, various electronic components).

2. Safety Precautions

  • Active Output: This instrument is an active output device. Do NOT use the test leads to test unpowered circuit boards, as this can damage the instrument and prevent it from powering on.
  • Capacitor Discharge: ALWAYS discharge capacitors before measuring their capacitance. Failure to do so will damage the instrument.
  • Battery Safety: The LCR-TC1 has a built-in Li-ion battery. Do NOT immerse the tester in water or expose it to heat sources. For your personal safety, strictly comply with Li-ion battery specifications and precautions.
  • Battery Voltage: Do not use the tester to measure battery voltage if it is below 4.5V, as this can damage the tester.

3. Setup

3.1 Unboxing and Components

Your LCR-TC1 Multi-function Tester package should include:

  • LCR-TC1 Multi-function Tester unit
  • Micro USB charging cable
  • Test leads with clips
  • Assorted electronic components for testing (e.g., LEDs, capacitor, transistor pins)

3.2 Charging the Battery

The tester features a built-in rechargeable Li-ion battery. Use the provided Micro USB cable to connect the tester to an external 5V power supply or a USB power source.

  • The charging indicator LED will be red during charging.
  • The charging indicator LED will turn green when charging is complete.
  • If the battery voltage drops below 3.1V, the tester will automatically shut down and require charging.

3.3 Initial Power On

In the power-off state, short press the multi-function key (Start button) to turn on the tester. It will automatically perform a self-test and measurement.

3.4 Automatic Calibration

For accurate measurements, it is recommended to perform an automatic calibration periodically or if you suspect inaccurate readings.

  1. Short-circuit all three test sockets (1, 2, and 3) on the ZIF socket.
  2. Short press the multi-function key (Start button). The tester will automatically begin calibration.
  3. During the calibration process, the display will prompt you to disconnect the short wire. Follow the on-screen instructions.
  4. Calibration is complete when the display shows "Selftest End".

4. Operating Instructions

Play video
Watch video online

Video 1: LCR-TC1 Multi-function Tester demonstration, including important usage warnings.

4.1 General Component Testing

  1. Ensure the component is discharged, especially capacitors.
  2. Insert the component leads into the appropriate test sockets (1, 2, or 3) on the ZIF socket. For most components, the order does not matter as the tester will identify the pins.
  3. Close the ZIF socket locking handle.
  4. Short press the multi-function key (Start button).
  5. The tester will automatically identify the component type and display its parameters on the TFT screen.

Important Note on Capacitor Placement:

Do NOT put capacitors into the KAA area (the lower row of pins on the ZIF socket) for measurement. If a capacitor is mistakenly placed there, ensure it is discharged before removal to prevent damage to the instrument.

4.2 Transistor Testing

The tester automatically detects NPN and PNP bipolar transistors, N-channel and P-channel MOSFETs, JFETs, and diodes (including double diodes). It also identifies N- and P-IGBTs, thyristors, and triacs.

  1. Place the transistor leads into any three test sockets (1, 2, 3).
  2. Press the Start button.
  3. The display will show the transistor type (e.g., BJT-NPN, BJT-PNP), pinout (Base, Collector, Emitter), and parameters like hFE (DC Current Gain), Ube (Base-Emitter Voltage), and Ic (Collector Current).

4.3 Zener Diode Testing

The LCR-TC1 can automatically detect Zener diodes and measure their forward voltage drop and reverse breakdown voltage (0.01-20V).

  1. Insert the Zener diode into the Zener diode test area (typically sockets 1 and 2, or 2 and 3, depending on the specific ZIF socket layout for Zener testing).
  2. Press the Start button.
  3. The display will show the Zener voltage (Uf).

Note: Do not put other components into the Zener diode test area, as this may prevent the Zener diode from being tested correctly.

4.4 IR Decoder Function

The tester includes an IR decoder function to analyze infrared remote control signals (supports Hitachi IR coding).

  1. After a component test is completed, point an infrared remote control at the "IR" test hole on the tester.
  2. Press a button on the remote control.
  3. The tester will display the user code and data code if decoding is successful, along with the corresponding infrared waveform.
  4. If decoding fails, the codes will not be displayed.

Note: This decoder only supports infrared encoding in Hitachi format. Other formats are not supported.

5. Maintenance

5.1 Battery Charging

Refer to Section 3.2 for detailed battery charging instructions. Ensure the battery is charged when the tester indicates low battery or automatically shuts down.

5.2 General Care

  • Keep the device dry and clean.
  • Avoid exposing the tester to extreme temperatures or direct sunlight.
  • Do not drop or subject the tester to strong impacts.
  • Store in a safe place when not in use.

6. Troubleshooting (FAQ & Known Issues)

6.1 Frequently Asked Questions (FAQ)

QuestionCauseSolution
Cannot power onLithium battery is lowCharge until the light turns green
Inaccurate measurementsPlease re-calibrate

6.2 Known Errors and Unsolved Problems

  • Germanium Transistors: The current amplification factor of germanium transistors may be measured too high due to high residual current. The basis emitter voltage will be very low in this case.
  • Schottky Diodes: Capacity value in reverse direction for Power Schottky Diodes (e.g., MBR3045PT) may not be measured if only one diode is connected, due to high residual current. Cooling the device (e.g., with cooling spray) might enable measurement.
  • Triac Gate Function: The diode function of a triac gate cannot be examined.
  • JFET Pin Detection: Source and Drain pins may not be detected correctly with JFETs due to their symmetrical structure. If the display shows the same layout with the same parameters when Source and Drain pins are swapped, this indicates the issue.
  • High-Power Components: The output current of the tester is 6mA/voltage <5V. High-power IGBTs, thyristors, and Darlington tubes requiring higher current/voltage drive may not be measured.
  • Inductance Measurement: Air core coils and power inductors cannot directly measure inductance. Series connection is recommended. For color ring inductance tests and capacitors below 20pF, it is recommended to test a 20pF capacitor.

7. Specifications

LCR-TC1 Features and Performance Parameters

Figure 2: LCR-TC1 Features and Performance Parameters Table.

7.1 General Specifications

  • Display Type: LCD Display (1.8-inch TFT, 160x128 pixels)
  • Operating Mode: Manual range
  • Operating Temperature: 0 - 40 ℃
  • DIY Supplies: Electrical
  • Certification: CE
  • Battery Included: Yes (Built-in 3.7V Li-ion)
  • Is Smart Device: No

7.2 Measurement Ranges

Component TypeRangeParameter Description
BJT-hFE, Ube, Ic, Iceo, Ices, Uf
DiodeForward voltage <4.50VForward voltage drop, junction capacitance, reverse leakage current Ir
Double Diode-Forward voltage
Zener Diode0.01-4.50V (Transistor Test Area)
0.01-20V (Zener diode test area)
Forward voltage drop, reverse breakdown voltage
JFET-Cg, Id at Vgs, UfForw
MOSFET-Id under Vgs, protection diode Uf (IGBT)
Vt, Cg, Rds, protection diode Uf (MOSFET)
Thyristor/TriacGate trigger current <6mAGate turn-on voltage
Capacitor25pF-100mFCapacitance Value, ESR, Vloss
Resistor0.01-50MΩResistance
Inductor0.01mH-20HInductance, DC Resistance
Battery0.1-4.5VVoltage value, battery polarity

7.3 Dimensions

LCR-TC1 Multi-function Tester dimensions

Figure 3: LCR-TC1 Multi-function Tester dimensions.

  • Length: 90mm (3.54 inches)
  • Width: 70mm (2.75 inches)

8. User Tips

  • Always double-check that capacitors are fully discharged before testing to prevent damage to the tester.
  • Avoid testing live circuits or components that are still powered.
  • If readings seem inconsistent, perform an automatic calibration.
  • Keep the ZIF socket clean and free of debris for reliable connections.

9. Warranty and Support

For any issues or support inquiries, please contact your seller. A detailed user manual in PDF format is available for download: View User Manual (PDF).

© 2024 Gaqqee. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.