1. Product Overview
The Gaqqee MODBUS-RTU RS485 Communication Display Meter is a versatile device designed for industrial and automation applications. It can operate in three distinct modes: Master, Slave, and Listen, allowing for flexible integration into existing MODBUS-RTU networks. This meter features a 5-digit 0.56-inch red LED display for clear data visualization and panel buttons for easy parameter configuration.

Key features include:
- Master Mode: Send read/write commands to slave devices.
- Slave Mode: Receive read/write commands from master devices.
- Listen Mode: Filter and extract required data from the MODBUS-RTU bus for display.
- Support for standard Modbus-RTU protocol.
- Panel buttons for parameter setting.
- Enhanced stability and anti-interference capabilities.
2. Setup and Installation
2.1 Package Contents
- 1 x MODBUS-RTU RS485 Communication Display Meter
2.2 Physical Installation
The display meter is designed for panel mounting. Ensure adequate space for the device and its wiring connections.
- Product Dimensions: 79mm (Length) x 43mm (Width) x 25mm (Depth)
- Installation Hole Size: 76.5mm x 39.5mm
2.3 Wiring Connections
Connect the device according to the wiring diagram below. Ensure all connections are secure and correctly polarized to prevent damage.

| Terminal | Description |
|---|---|
| PWR | DC Power Input (8V to 25V) |
| GND | Ground Connection |
| M1A | Modbus Data Line A (Specific to internal Modbus communication) |
| M1B | Modbus Data Line B (Specific to internal Modbus communication) |
| 485- | RS485 Data Line B (Negative) |
| 485+ | RS485 Data Line A (Positive) |
Power Supply: The device requires a DC power input ranging from 8V to 25V. Ensure your power source meets these specifications.
3. Operating Instructions
3.1 Panel Buttons
The front panel features four buttons for navigation and parameter setting:
- SET: Enters/exits the setting menu.
- Up Arrow (∧): Increments values or navigates up in menus.
- Down Arrow (∨): Decrements values or navigates down in menus.
- OK: Confirms selections or saves settings.
3.2 Operating Modes
The meter supports three primary operating modes:
3.2.1 Slave Mode
In Slave mode, the display meter receives write data from a master device (e.g., PLC, touch screen, PC) via the MODBUS-RTU bus and displays the received data.

3.2.2 Master Mode
In Master mode, the display meter distributes read commands (up to 3 frames, regardless of device address) to sensor/acquisition tables and displays the acquired sensor data. It can also send write commands to control other equipment.

3.2.3 Listen Mode
In Listen mode, the display meter filters and acquires specified sensor data from the existing network (MODBUS-RTU bus) and displays it without actively sending commands or responding as a slave.

3.3 Parameter Setting
All operational parameters, including Modbus address, baud rate, and display settings, can be configured using the panel buttons. Refer to the detailed PDF user manual for specific menu structures and parameter definitions.
4. Maintenance
The MODBUS-RTU RS485 Communication Display Meter is designed for reliable operation with minimal maintenance. To ensure longevity and optimal performance:
- Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Avoid exposing the device to extreme temperatures, high humidity, or corrosive environments.
- Ensure all wiring connections remain secure.
5. Troubleshooting
5.1 Communication Error Indication
If a communication error occurs, the display may show "E.con0".

If "E.con0" is displayed:
- Check all RS485 wiring connections for proper polarity (485+ to 485+, 485- to 485-) and secure contact.
- Verify the Modbus address and baud rate settings on the display meter match those of the communicating device.
- Ensure the master device is actively sending commands or the slave device is properly configured to respond.
- Check for any physical damage to the RS485 bus or connectors.
5.2 No Display/Power
- Verify the power supply voltage is within the DC 8V-25V range.
- Check power wiring connections (PWR and GND) for proper contact and polarity.
- Ensure the power supply is active and providing sufficient current.
6. Specifications

| Parameter | Value |
|---|---|
| Rated Power Supply Voltage | DC 8V ~ 25V |
| Power Consumption | 24V/50mA |
| Communication Interface | RS485 |
| Screen Display | 5 bits 0.56 inch digital tube (Red) |
| Product Size (L x W x D) | 79mm x 43mm x 25mm |
| Installation Hole Size | 76.5mm x 39.5mm |
| Protocol Support | Standard Modbus-RTU |
| Operating Modes | Master, Slave, Listen |
| Stability | Better stability and anti-interference ability (compared to analog) |
7. User Tips
- Technical Support: If you encounter complex technical issues, the seller may be able to provide support. Be prepared for potential language differences in communication.
- Manual Reference: This document serves as a primary instruction manual. For more in-depth technical details and advanced configurations, please refer to the official PDF user manual provided by the seller, if available.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your point of purchase or the official Gaqqee seller directly. Please have your product model and purchase details ready when contacting support.
A detailed PDF user manual may be available for download from the seller's product page or upon request. This PDF manual (e.g., User Manual PDF) often contains advanced configuration details and troubleshooting steps not covered in this general guide.