1. Introduction
This manual provides essential information for the safe and efficient operation of your ZJIVNV LRS-150W Single Output Switching Power Supply. Please read this manual thoroughly before installation and use, and keep it for future reference.
The LRS-150W is a compact, full-power switching power supply designed for various electronic equipment, offering multiple output voltage options (12V, 24V, etc.) and built-in protection features.
2. Safety Instructions
WARNING: Failure to follow these safety instructions may result in electric shock, fire, or damage to the product.
- Always ensure the input and output lines are correctly connected (Live, Neutral, Earth for AC; Positive, Negative for DC).
- Verify that the cross-section of the input electric wire is sufficient to prevent excessive voltage drop (AC voltage drop not exceeding 5%, DC voltage drop not exceeding 0.5%).
- Ensure all screw connections and switching device contacts are secure.
- The earth wire must be firmly grounded to ensure safety and reduce interference. The cross-sectional surface of the grounded copper wire should exceed 0.75mm².
- Before powering on, check the insulation resistance between input/output and the casing, and ensure it meets required withstand voltage levels.
- Do not use screws that are too long, as they may touch internal circuit boards or components, causing damage or danger.
- If your model has an input voltage selector switch, ensure it is set correctly (e.g., 110V or 220V) to match your local mains supply before connecting power. Incorrect setting can damage the power supply.
- Avoid operating the power supply in abnormal environments (high temperature, high humidity, dust, acid-base pollution) as this can significantly reduce its service life.
- Remove all plastic packaging before installation.
- If the supply voltage fluctuates dramatically (over-voltage/low-voltage), consider installing a power stabilizer or over/under voltage protector.
- When supplying power to large electrical equipment, consider installing an AC filter before the power supply.
- The power supply can operate at full load within its specified ambient temperature range. If the environment temperature exceeds the upper limit, reduce the output power according to the power-output curve. For example, at 70°C, output power should not exceed 50% of the rated value.
- If the environment temperature is below -10°C, the power supply may not start or output normally.
- Ensure the power supply's working environment has unblocked airflow for proper cooling; otherwise, its lifespan will be shortened.
- Frequent switching on/off of the input voltage or abnormal input conditions will affect the lifespan of the unit.
3. Product Overview
The ZJIVNV LRS-150W is a high-efficiency, single-output switching power supply. It features a compact design, full power output, and is suitable for a wide range of electronic applications.
Features:
- Full Power Output in a Small Size
- Available in Various Output Voltages (e.g., 12V, 24V)
- Built-in Cooling Fan for Efficient Heat Dissipation
- Comprehensive Protection: Short Circuit, Overload, Over Temperature
- Pure Copper Coil and Transformer for Reliability
Applications:
This power supply is applicable to all kinds of electronic equipment, including:
- Automated Industry Equipment
- Electric Equipment
- Scientific Research Equipment
- LED Lighting
- Industrial Control Systems
- Monitoring Equipment
- Audio Equipment
- Medical Equipment

Figure 3.1: ZJIVNV LRS-150W Power Supply Top View

Figure 3.2: Quality Assurance Protections (Short Circuit, Overload, Over Temperature)
4. Specifications
| Parameter | Value |
|---|---|
| Model Number | LRS-150W |
| Type | Power Supply |
| Output Power | 150W |
| Output Type | SINGLE |
| Input Voltage Range | 100-240VAC |
| Output Frequency | 50HZ |
| Rated Capacity | <40VA |
| EU LVD Voltage | Low voltage: Below 50Vac or 75Vdc |
| Product Size (L*W*H) | 159*97*30mm |
| Weight | 0.38KG |
Output Voltage and Current Options:

Figure 4.1: Available Output Voltage and Current Configurations
Detailed Technical Specifications:

Figure 4.2: Comprehensive Technical Specification Table
Note: For full details, refer to the comprehensive technical specification table above.
5. Setup and Installation
- Unpacking: Carefully remove the power supply from its packaging. Inspect for any visible damage.
- Environment: Install the power supply in a well-ventilated area, free from excessive dust, moisture, and corrosive gases. Ensure adequate clearance around the unit for proper airflow.
- Input Voltage Selection (if applicable): Locate the voltage selector switch (usually a small yellow switch near the input terminals). Set it to match your local AC mains voltage (e.g., 110V or 220V). Failure to set this correctly will damage the unit.
- Mounting: The power supply is designed for fixed installation. Secure it using appropriate screws through the mounting holes on the chassis. Ensure the mounting surface is stable and non-conductive.
- Wiring: Proceed to the "Wiring Layout" section for detailed connection instructions.
- Pre-Power Check: Before applying power, double-check all wiring connections for correctness and security. Ensure the earth wire is properly grounded.
6. Wiring Layout
Refer to the diagram below for correct wiring connections. All connections should be made with the power supply disconnected from the mains.

Figure 6.1: Wiring Diagram and Terminal Identification
Terminal Descriptions:
- L (Input Live Wire): Connect to the AC Live (Phase) line.
- N (Input Neutral Wire): Connect to the AC Neutral line.
- ⌀ (Input Earth Wire): Connect to the protective earth ground. This connection is critical for safety.
- -V (Output Negative): Connect to the negative terminal of your DC load.
- +V (Output Positive): Connect to the positive terminal of your DC load.
- ADJ (Adjust Output ±10%): This potentiometer allows for fine adjustment of the output voltage within a ±10% range of the nominal voltage. Use a small screwdriver to turn it.
Ensure all wires are securely fastened to their respective terminals to prevent loose connections, which can cause overheating or intermittent operation.
7. Operating Instructions
- Power On: After all connections are verified and secure, apply AC power to the input terminals. The power supply should begin operating.
- Output Voltage Adjustment: If precise output voltage is required, use a multimeter to measure the output voltage across the +V and -V terminals. Carefully turn the ADJ potentiometer with a small screwdriver until the desired voltage is achieved within the ±10% adjustment range.
- Load Connection: Connect your DC load to the +V and -V terminals. Ensure the load's current draw does not exceed the rated output current of the power supply for the selected voltage.
- Main and Secondary Outputs: For multi-output power supplies (though this model is single output, general principles apply), the main output typically has superior characteristics. If a secondary output is used alone, a dummy load of at least 30% of the rated power output might be required on the main output to ensure stable operation.
8. Maintenance
- Cleaning: Keep the power supply clean and free from dust accumulation, especially around ventilation openings, to ensure proper cooling. Use a soft, dry cloth for cleaning.
- Ventilation: Regularly check that the ventilation openings are not obstructed. Ensure the cooling fan (if present and active) is operating correctly.
- Connections: Periodically inspect all wiring connections for tightness and signs of corrosion.
- Environmental Conditions: Maintain the operating environment within the specified temperature and humidity ranges to prolong the lifespan of the unit.
- Avoid Frequent Cycling: Minimize frequent power cycling (turning on and off) of the input voltage, as this can reduce the lifespan of the power supply.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No output voltage |
|
|
| Unstable output voltage |
|
|
| Unit shuts down unexpectedly |
|
|
If the problem persists after attempting these solutions, please contact the seller for further assistance.
10. User Tips
- Load Management: To ensure the longevity and stable performance of your power supply, it is recommended not to operate it at full load continuously. Aim to use approximately 80% of the rated power. For example, for a 150W power supply, the actual load should ideally not exceed 120W.
- Ventilation is Key: Always ensure the power supply has adequate ventilation. Blocked vents can lead to overheating and premature failure.
11. Certifications
This ZJIVNV LRS-150W Switching Power Supply is certified to meet the following standards:
- CE: Conforms to European Union safety, health, and environmental protection requirements.
- FCC: Complies with Federal Communications Commission standards for electromagnetic compatibility.
- RoHS: Compliant with the Restriction of Hazardous Substances Directive.

Figure 11.1: Product Certifications Overview
12. Warranty and Support
This product comes with a 1-year warranty from the date of purchase.
For warranty claims, technical support, or any inquiries regarding your ZJIVNV LRS-150W Switching Power Supply, please contact your original seller or authorized distributor. Please have your purchase details and model number ready when contacting support.