1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your KeepLiNK 9-Port Multi-Gigabit PoE Switch. Please read this manual thoroughly before using the device to ensure proper functionality and safety.

The KeepLiNK KP-9000-9XHP-X is a high-performance multi-gigabit PoE switch designed to meet modern network demands. It features 8x 2.5Gb Ethernet ports with PoE+ capabilities and a 1x 10Gb SFP+ uplink port, offering flexible and high-speed connectivity for various network devices.

KeepLiNK 9-Port Multi-Gigabit PoE Switch front view

Figure 1: KeepLiNK 9-Port Multi-Gigabit PoE Switch (KP-9000-9XHP-X)

2. Packing List

Please check the contents of your package. If any items are missing or damaged, contact your vendor.

  • Device (KeepLiNK 9-Port Multi-Gigabit PoE Switch)
  • AC power cord (for built-in power supply device)
  • User manual
  • Certificate of conformity
  • Hanging ears and screws (for rack-mounted devices)

3. Product Overview

3.1 Key Features

  • 8 x 1G/2.5G Ethernet Ports
  • 8 x PoE+ Ports
  • 1 x 1G/10G SFP+ Port
  • Silent Operation (Fan-less design)
  • Desktop or Wall Mount installation options
  • Dimensions (H x W x D): 190 x 140 x 44 mm
  • Plug-and-Play: No configuration or software necessary for basic operation.
Key Features of KeepLiNK Multi-Gigabit PoE Switch

Figure 2: Key Features and Dimensions

3.2 Front Panel Layout

Front panel of KeepLiNK 9-Port Multi-Gigabit PoE Switch showing Ethernet and SFP+ ports

Figure 3: Front Panel

The front panel includes:

  • L1-L8: 2.5G Ethernet Switch ports (8 ports, supporting PoE)
  • R1-R8: Link/Act indicators for 10/100/1000M speeds
  • 9 (10G): SFP+ port (1 port, supporting 1G/10G uplink)
  • S: System status indicator
  • 9: SFP+ port status indicator
  • P: PoE status indicator

3.3 Rear Panel Layout

Rear panel of KeepLiNK 9-Port Multi-Gigabit PoE Switch showing AC input and grounding terminal

Figure 4: Rear Panel

The rear panel includes:

  • AC INPUT 100~240V: Power input port
  • Grounding Terminal: For connecting to an earth ground

4. Setup and Installation

4.1 Installation Precautions

Network Cable Requirements:

  • For 100Mbps connections: Use Cat5 or above Ethernet cable.
  • For 1000Mbps/2.5GE/5GE connections: Use Cat5e or above Ethernet cables.
  • For 10GE connections: Use Cat6a or above Ethernet cables.

Fiber Optic Cable Requirements:

  • Fiber optics and connectors must be used in conjunction with optical modules.
  • The bending radius of the optical fiber should not be less than 40mm.

Safety Precautions:

  • Always keep the power off during installation.
  • Ensure the power supply voltage matches the switch's requirements (AC 100-240V).
  • Do not overload the power circuit.
  • To avoid electric shock, do not open the switch casing while it is in operation or attempt repairs yourself.

Environmental Precautions:

  • Maintain appropriate temperature (-10℃ to +50℃) and humidity for long-term stable operation.
  • Ensure good grounding of the equipment to avoid static electricity.
  • Keep the switch away from high-frequency, high-power, and high-current equipment to reduce electromagnetic interference.
  • For lightning protection, ensure racks, power sockets, and ground are in good contact. Use signal lightning protectors for outdoor wiring.

4.2 Installation Methods

The switch supports desktop, rack, and wall-mounted installations.

4.2.1 Rack-Mounted Installation

  1. Prepare the hanging ears and screws.
  2. Secure the hanging ears to both ends of the device using the provided screws.
  3. Push the device parallel to the tray into the cabinet.
  4. Secure the device to the cabinet using cabinet screws.
Diagram showing rack-mounted installation of the switch

Figure 5: Rack-Mounted Installation

4.2.2 Desktop Installation

  1. Place the switch on a flat and secure desktop.
  2. Ensure sufficient ventilation and heat dissipation space around the device.
  3. Attention: Do not place heavy objects on the switch.

4.2.3 Wall-Mounting Installation

  1. Fix screws on the wall according to the position of the wall mounting holes on the device. Ensure a distance of 3mm ± 0.5mm between the nuts and the wall.
  2. Align the wall mounting holes on the device with the screws for installation and fixation.
Diagram showing wall-mounting installation steps: punch holes, embed nails, mount switch

Figure 6: Wall-Mounting Installation

4.3 Initial Connection

Connect the AC power cord to the switch's rear panel and plug it into a power outlet. The switch will power on automatically.

Connect your network devices (e.g., WiFi 6 Access Point, Security Camera, IP Phone, NAS, Computer) to the 2.5G Ethernet ports (L1-L8) using appropriate Ethernet cables. For uplink to a router or core switch, use the 10G SFP+ port (9).

Diagram showing typical network connections to the Multi-Gigabit PoE Switch

Figure 7: Typical Network Connections

KeepLiNK 9-Port Multi-Gigabit PoE Switch with connected devices

Figure 8: Plug-and-Play Connectivity

5. Operating Instructions

5.1 Product Indicator Lights

Monitor the status of your switch using the indicator lights on the front panel:

Sign Definition Status Description
PWR/P Power indicator light Green light always on/off Power is connected/not connected
AI POE AI light Green light on/off AI PoE started/not started
SYS/NMS/S/N System light Green light on/off System working/system not started
100Mbps copper port Connection status indicator light Left light Speed Yellow light always on 100M speed
Yellow light off 10M speed
Right light Link/act Green light always on Port connected
Green light off Port not connected
Green light blink The port is connected and there is data transmission and reception
1000Mbps copper port Connection status indicator light Left light Speed Yellow light always on 1000M speed
Yellow light off 10/100M speed
Right light Link/act Green light always on Port connected
Green light off Port not connected
Green light blink The port is connected and there is data transmission and reception
2.5G copper port Connection status indicator light Left light Speed Yellow light on 2.5G speed
Yellow light off or green light always on 10/100/1000M speed
Right light Link/act Green light always on Port connected or 10/100/1000M speed
Green light off Port not connected
Light blink The port is connected and there is data transmission and reception
10G copper port Connection status indicator light Left light Speed Yellow light on 10G speed
Green light on 5G speed
Light blink Data transmission and reception
10G downlink fiber port Connection status indicator light Link/act Yellow light always on 10G speed
Green light always on 1G rate
Light off Port not connected
Light blink The port is connected and there is data transmission and reception
Optical port connection status indicator light Link/act Green light on Port connected
Green light off Port not connected

5.2 DIP Switch Settings

The switch features DIP switches for various functions. The specific definitions depend on whether it's a PoE or Non-PoE switch, and the number of DIP switches.

Note: The specific DIP switch definition shall be based on the actual product.

5.2.1 DIP Switch Definition of Non-PoE Switch (Example)

DIP switch specification Sequence Definition of DIP switch Description
4 DIP Switch 1 Reserve Reserve
2 Extend 250m long distance transmission (downlink port)
3 Port Isolation Port isolation
4 Storm Control Suppress broadcast data

5.2.2 DIP Switch Definition of PoE Switch (Example)

DIP switch specification Sequence Definition of DIP switch Description
4 DIP Switch 1 AI POE Auto detect and reboot unresponsive PoE devices for recovery
2 Extend 250m long distance transmission (PoE port)
3 Port Isolation Port isolation
4 Storm Control Suppress broadcast data
3 DIP Switch 1 Extend 250m long distance transmission (PoE port)
2 Standard Normal mode
3 Port Isolation Port isolation
2 DIP Switch 1 Extend 250m long distance transmission (PoE port)
2 AI PoE/Reserve AI PoE/Reserve

5.2.3 DIP Switch Definition of Lite Management Switches (Example)

DIP switch specification Sequence Definition of DIP switch Description
3 DIP Switch 1 Web-managed WEB management
2 Standard Standard mode
3 Port Control Port isolation

5.3 PoE Powered Function

This switch supports Power over Ethernet (PoE) on its 2.5G Ethernet ports (L1-L8). It is compatible with IEEE802.3af/at standards.

  • PoE Protocols: IEEE802.3af (15.4W), IEEE802.3at (30W).
  • PoE Power Budget: 135W total.
  • Max Power per Port: 30W.
  • PoE Pinout: 1,2,3,6.
  • Standard PoE switches automatically detect and provide power to standard PoE devices. Non-PoE devices will only transmit data without receiving power.
Play video
Watch video online

Video: Overview of the KeepLiNK Multi-Gigabit PoE Switch.

5.4 Management (for Managed Switch Models)

This section applies only to network management products. If your switch is an unmanaged model, you can skip this section.

5.4.1 WEB Management

  1. Connect the device to a PC and ensure device initialization is complete.
  2. Configure the IP address of the PC and the default IP address of the switch to be in the same network segment.
  3. Open a web browser on your PC and input "http://192.168.1.168". Press "Enter" to access the network management login interface.
  4. Enter the default username "admin" and password "admin" to log in.
Example of web management login interface

Figure 9: Web Management Login Interface (Placeholder image, actual interface may vary)

5.4.2 Console Port Management

  1. Use a console port cable to connect the console port of your PC to the switch.
  2. Open terminal simulation software (e.g., PuTTY, Tera Term).
  3. Establish a connection, select the serial port, and configure communication parameters:
    • Transmission rate: 115200
    • Data bit: 8
    • Check digit: None
    • Stop bit: 1
    • Flow control method: None

6. Specifications

Attribute Value
Brand NamekeepLiNK
Model NumberKP-9000-9XHP-X-AC
Switch TypeGigabit Switch
Number of Interfaces10 (8-PoE and 1-SFP+)
Transmission Rate10000 Mbps
Switch Capacity60Gbps
Communication ModeFull-Duplex & Half-Duplex
VLANYes
FunctionPOE, VLAN Support
CertificationCE, FCC, RoHS
OriginMainland China
Input voltageAC100-240V/50-60Hz
Standby Power10W
PoE Port1-8
PoE ProtocolIEEE802.3af/at
PoE Power Budget135W
PoE Pinout1,2,3,6
Max Power each port30W
Packet forwarding rate44.64Mpps
MAC address table4K
Buffer8.1Mbit
Forwarding delay<10us
MDX/MDIXyes
Jumbo Frame16Kbytes
Operating temperature-10℃~+50℃
Storage temperature-40℃~+70℃
Thermal methodsFan-less
Dimension190 x 140 x 44 mm
Installation MethodDesktop or wall mount
Weight0.8 kg

7. Troubleshooting

7.1 Common Issues

  • No Power: Ensure the power cord is securely connected and the power outlet is functional. Check the PWR/P indicator light.
  • No Link: Verify that Ethernet cables are properly connected to both the switch and the connected device. Check the Link/Act indicator lights for the respective ports. Ensure the correct cable type is used for the speed (e.g., Cat5e for Gigabit).
  • PoE Device Not Powering On: Confirm the connected device is PoE compatible (IEEE802.3af/at). Check the PoE status indicator (P). If using a managed switch, ensure PoE is enabled for the port.
  • Slow Network Speed: Check the speed indicator lights for the ports. Ensure connected devices and cables support the desired speed (e.g., 2.5G). Verify no network loops are present.
  • Network Congestion: If experiencing high broadcast traffic, consider enabling Storm Control via DIP switches (if available and applicable to your model) or through web management for managed switches.

7.2 User Tips

  • Uplink Port Flexibility: The 10G SFP+ port can function as both a 1G and 10G uplink, providing versatility for connecting to different network infrastructures.
  • Rackmount Ears: The switch comes with rackmount ears, making it suitable for standard 19-inch rack installations.
  • Managed vs. Unmanaged: This model (KP-9000-9XHP-X) is an unmanaged switch, meaning it's plug-and-play with no complex configuration required. Some variants might offer lite management features via DIP switches or a web interface. Refer to the DIP switch section for details specific to your model.

8. Warranty and Support

8.1 After-sales Service Letter of Commitment

Within seven days from the date of sale, if the whole device fails, you can choose to repair, replace, or return it. If performance failure occurs within seven days to one year from the date of sale (based on the date of purchase invoice and proof of three guarantees), the whole machine can be selected for repair or replacement.

Beyond the one-year hardware warranty period, the cost of replacing the hardware will be borne by the user, and our company will not add other costs.

We provide 7x24 hour after-sales support services.

8.2 Circumstances Without Warranty Coverage

Failure or damage of equipment (including parts) under the following circumstances are not covered by warranty:

  • Accessories supplied by other companies (e.g., power supply, adapter) are guaranteed by their respective manufacturers.
  • The whole machine and parts have exceeded the warranty period.
  • Equipment failure or damage not caused by repair, alteration, or demolition by our company's personnel.
  • Malfunctions caused by accidental or artificial causes, including improper operation, scratching, handling, moving, knocking, and inputting inappropriate voltage.
  • Failure or damage caused by the use of non-genuine or unpublished software.
  • Failures or losses caused by natural disasters, such as force majeure (e.g., earthquakes and fires).

8.3 User Manual (PDF)

A comprehensive user manual in PDF format is available for download. This document contains additional detailed information and diagrams.

For the full user manual, please refer to the official PDF document: KeepLiNK Ethernet Switch User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.