1. Introduction

The OWON CM2100 AC/DC clamp ammeter is a high-reliability, high-safety, high-accuracy, and small-sized instrument. It features a resolution of 1mA and a maximum range of 100A AC/DC. This product includes a unique VFC start-up mode for accurate voltage and current measurements, True RMS for voltage and current, full-range overload protection, and a reliable measuring precision with a distinctive design, making it an essential electrical/electronic measuring tool.

1.1. General Inspection

Upon receiving your new clamp ammeter, perform the following checks:

  1. Check for Transportation Damage: Inspect the packaging carton and foam cushioning for any serious damage. If damage is found, retain the packaging until the device and accessories have passed electrical and mechanical property tests.
  2. Check the Accessories: Refer to the 'Appendix' section for a list of included accessories. Verify that all items are present and undamaged. Contact your distributor if any accessories are missing or damaged.
  3. Check the Complete Instrument: Examine the instrument for any visible damage or signs of malfunction. If the instrument appears damaged or does not operate normally, contact your distributor. If transportation damage is suspected, keep the original packaging.

2. Safety Information

2.1. Safety Considerations

Warning: To prevent bodily injury or damage to the product, always adhere to the following safety precautions:

  • Limit operation to the specified measurement category, voltage, or amperage ratings.
  • Do not use the clamp ammeter if it is damaged. Inspect the case for cracks or missing plastic, especially around connectors.
  • Use only the certified test leads specified for this product. Inspect test leads for damaged insulation or exposed metal.
  • Before use, verify the clamp ammeter's operation by measuring a known voltage.
  • Maintenance should only be performed by qualified technicians.
  • Always use the specified battery type (AAA1.5V x 2). Observe correct polarity when inserting batteries.
  • Check all Terminal Ratings to avoid fire or shock hazards. Refer to this manual for detailed ratings.
  • Do not operate the clamp ammeter with the cover or portions of the cover removed or loosened.
  • Use only the specified type and rating fuse for the clamp ammeter.
  • If you suspect damage, do not operate the clamp ammeter. Have it inspected by qualified service personnel.
  • To avoid electric shock, do not operate this product in wet or damp conditions.
  • Do not operate in an explosive atmosphere.
  • Keep product surfaces clean and dry.
  • Do not apply more than the rated voltage between terminals or between terminal and earth ground.
  • When servicing, use only specified replacement parts.
  • Use caution when working above 60 V DC, 30 V AC RMS, or 42.4 V peak, as these voltages pose a shock hazard.
  • When using test leads, keep your fingers behind the finger guards.
  • Remove test leads from the clamp ammeter before opening the battery cover.
  • Replace the battery as soon as the low battery indicator ⚙ appears and flashes to avoid false readings.
  • Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.
  • Use the proper terminals, function, and range for your measurements. If the value is unknown, set the rotary switch to the highest range or auto-ranging mode. Do not exceed maximum input limits.
  • Connect the common test lead first, then the live test lead. Disconnect the live test lead first when removing leads.
  • Disconnect test leads from the circuit under test before changing functions.

2.2. Measurement Category Definition

  • Measurement CAT I: Applies to measurements on circuits not directly connected to the AC mains, or specially protected (internal) mains-derived circuits.
  • Measurement CAT II: Protects against transients from energy-consuming equipment supplied from fixed installations (e.g., TVs, PCs, portable tools, household circuits).
  • Measurement CAT III: Protects against transients in fixed equipment installations (e.g., distribution panels, feeders, short branch circuits, lighting systems in large buildings).
  • Measurement CAT IV: Applies to measurements at the source of low-voltage installations (e.g., electricity meters, primary overcurrent protection devices, ripple control units).

2.3. Safety Terms and Symbols

The following terms and symbols may appear in this manual and on the product:

  • Warning: Indicates conditions or practices that could result in personal injury or death.
  • Caution: Indicates conditions or practices that could result in damage to this product or other property.
  • Danger: Indicates an immediate injury or hazard.
  • Warning (on product): Indicates a potentially accessible injury or hazard.
  • Caution (on product): Indicates potential damage to the instrument or other property.
Safety Symbols
SymbolDescription
⏑Direct current (DC)
⏐Fuse
∿Alternating current (AC)
≈Both direct and alternating current
⚠Caution, risk of danger
★Ground terminal
ⒸConforms to European Union directives (CE)
□Equipment protected throughout by double insulation or reinforced insulation

3. Product Features and Components

3.1. Product Panel Diagram

Familiarize yourself with the components of your clamp ammeter:

OWON CM2100B Clamp Meter with labeled parts: NCV sensor, Pincher head trigger, Numerical lock Backlight switch, LCD, Function selection knob, DCA reset/BLE Function selector, NCV light, Capacity/resistance/voltage/frequency/diode/ON-OFF input jack, Common-end jack.
  1. Clamp head: Used for clamping around a conductor to measure current.
  2. Protective baffle plate: Provides protection for the clamp head.
  3. Clamp head trigger: Press to open the clamp head.
  4. ZERO button: Used for zeroing DC current (DCA) measurements and for relative capacitance/voltage. Press and hold for about 2 seconds to enable/disable Bluetooth.
  5. HOLD/Backlight Button: Used for locking measured readings. Press and hold for about 2 seconds to enable/disable backlight.
  6. LCD display: Shows measurement function, symbols, and values.
  7. COM input jack: Insert the black probe here for voltage, resistance, continuity, capacitance, diode, frequency, and duty cycle tests.
  8. Positive end input jack: Insert the red probe here for voltage, resistance, continuity, capacitance, diode, frequency, and duty cycle tests.
  9. NCV and alarm indicator: Flashes when induced AC electric field strength meets specified values or when measurement exceeds range.
  10. SELECT button: Used to select functions like ACV/DCV, resistance/continuity/capacitance/diode, ACA/DCA, frequency/duty cycle. Press and hold for 2 seconds to enter/exit VFC function when AC current/voltage is selected.
  11. Function Selection knob: Rotate to select the desired measurement function.
  12. Geometric center indication mark: Indicates the optimal position for the wire within the clamp head.
  13. NCV induction antenna: Used for non-contact voltage detection.

3.2. LCD Full-Display Diagram

The LCD provides clear visual feedback on measurements and settings:

OWON CM2100B LCD display showing AUTO, H, ZERO, MIN MAX, VFC, °C°F, %, nF VAF, M kΩ Hz symbols and a 20000 Counts reading.
LCD Display Symbols
No.SymbolDescription
1★Enable Bluetooth
2AUTOAutomatic range
3HEnable reading holding mode
4ZEROZeroing base number
5→Select diode test
6○))Select continuity test
7VFCPrompt of variable frequency voltage/current measurement
8°C°FMeasurement unit of temperature, °C/°F
9%Percentage: Select duty cycle measurement
10nF VAFMeasurement unit of voltage, current, and capacitance
11M kΩ HzMeasurement unit of resistance and frequency
1218.8.8.8Measured value display; if out of range, "OL" will be displayed
13⚙Insufficient battery level
14ACAC measurement mode
15−Negative polarity indication of current or voltage
16DCDC measurement mode
17APOAutomatic shutdown

4. Operating Instructions

4.1. Measurement of AC/DC Voltage

  1. Select the AC or DC voltage function using the function selection knob.
  2. Insert the red probe into the red hole (positive pole) and the black probe into the black hole (COM terminal).
  3. Contact the red and black probes to the tested parts (e.g., power outlets).
  4. Read the measured value from the LCD screen.
Diagram showing correct probe connection for voltage measurement. The black probe is in the COM jack and the red probe is in the VΩ jack, connected across a voltage source.

Warning: When measuring voltage, the maximum input voltage is 600V (AC/DC). Exceeding this limit can cause electric shock and damage the instrument.

4.2. Measurement of AC/DC Current

Warning: Before measuring current, remove the test probes to avoid electric shock.

AC Current Measurement:

  1. Select the current range (2A, 20A, 100A) using the function selection knob. Press the SELECT/V.F.C button to enable the AC current flow function.
  2. Open the clamp head and hook a single wire. Ensure the wire is placed in the geometric center of the clamp head and that the clamp head is completely closed with no gap.
  3. Read the measured data from the LCD.
Diagram showing correct and incorrect ways to clamp a wire for AC current measurement. Correct shows a single wire centered in the clamp. Incorrect shows multiple wires or a wire not centered.

Figure 4: Correct and Incorrect Clamping for AC Current

DC Current Measurement:

  1. Select the current range (2A, 20A, 100A) using the function selection knob. Press the SELECT/V.F.C button to enable the DC current flow function.
  2. Press the ZERO button before measurement to set the reading to zero. Note: For accurate DC current measurement, ensure the instrument's measurement direction is consistent with the zeroing direction.
  3. Open the clamp head and hook a single wire. Ensure the wire is placed in the geometric center of the clamp head and that the clamp head is completely closed with no gap.
  4. Read the measured data from the LCD. A positive reading indicates current flows from the positive pole to the negative pole of the clamp head, while a negative reading indicates current flows from the negative pole to the positive pole.
Diagram showing correct and incorrect ways to clamp a wire for DC current measurement. Correct shows a single wire centered in the clamp. Incorrect shows multiple wires or a wire not centered.

Figure 5: Correct and Incorrect Clamping for DC Current

4.3. Non-Contact Electric Field Measurement (NCV)

Warning: When the function is switched to NCV, remove the test probes to avoid electric shock.

  1. Select the NCV function using the function selection knob.
  2. Keep the NCV induction antenna at the front of the clamp head close to the measured object (8-15mm distance) for detection.
  3. If the induced voltage is less than 90V, "EF" will be displayed. If greater than 90V, "-" will be displayed, with four segments indicating voltage intensity.
  4. A beeping alarm will sound with different rhythms, and the NCV indicator will flicker to indicate the intensity of the induced voltage.
Diagram showing the NCV function in use, with the clamp head near a live wire and the NCV indicator flashing.

Figure 6: NCV Measurement

4.4. Resistance / Circuit ON/OFF / Diode / Capacitance Measurement

Warning: When measuring resistance, continuity, capacitance, or diode, the input voltage must not exceed 60V (DC) or 30V (AC) to ensure personal safety.

  1. Select the resistance/continuity/capacitance/diode function using the function selection knob.
  2. Insert the red probe into the red hole (positive pole) and the black probe into the black hole (COM terminal).
  3. Connect the probes to the tested part.
  4. Read the measured data from the LCD screen.
Diagram showing probe connection for resistance measurement across a resistor.

Figure 7: Resistance Measurement

4.5. Measurement of Frequency and Duty Cycle

  1. Select the frequency/duty cycle function using the function selection knob.
  2. Insert the red probe into the red hole (positive pole) and the black probe into the black hole (COM terminal).
  3. Contact the red and black probes to the tested part (e.g., power socket).
  4. Read the measured data from the LCD screen.
Diagram showing probe connection for frequency measurement across a power socket.

Figure 8: Frequency Measurement

4.6. Other Functions

  • LCD Backlight: Press and hold the HOLD button for about 2 seconds to turn the LCD backlight on or off.
  • Automatic Shutdown (APO): If the function knob is not operated for approximately 15 minutes during measurement, the meter will automatically shut down to save energy. To restart, turn the knob to the OFF position and then back on, or press any button to wake the instrument.
  • Enable/Disable Automatic Shutdown: To disable, press and hold the SELECT key, then turn on the power switch. Three beeps will indicate that APO is canceled. APO will be restored when the instrument is turned off and on again. The instrument will beep 3 times continuously about 1 minute before automatic shutdown, followed by a long beep before shutdown. If APO is canceled, three continuous alarm beeps will be given every 15 minutes.
  • Buzzer: A short "Beep" (approx. 0.25 seconds) sounds when any button is pressed or the function switch is turned. In continuity mode (○)), the buzzer rings continuously if the tested circuit is well-conducted (≤50Ω). Continuous intermittent beeps indicate an over-range warning for voltage or current.
  • Low Voltage Detection: When the battery voltage drops below 2.5V, the low battery symbol ⚙ will appear, indicating that measurement accuracy may be reduced and batteries need replacement. If the voltage drops below 2.2V, only the low battery symbol will be displayed after boot.

5. Bluetooth Connectivity and APP Operations (CM2100B Only)

The CM2100B clamp ammeter can connect to mobile devices via Bluetooth for enhanced functionality, including remote control, data viewing, chart display, and data storage in CSV format. The effective Bluetooth communication distance is 7-8 meters, extending to over 20 meters in open, unshielded environments. The Bluetooth function automatically turns off after 10 minutes of inactivity, preceded by two short beeps.

5.1. Installation of Free APP

Requirements for Mobile Device System:

  • Bluetooth 4.0 Android APP: Applicable for Android 6.0 or above systems and Bluetooth BLE 4.0 Android devices.
  • Bluetooth 4.0 iOS APP: Applicable for iOS 11.0 or above systems and Bluetooth BLE 4.0, but not for iPhone 5 and older models.

For Android Device:

Scan the QR code below with your mobile device to download and install the APP installation package.

QR code for downloading the OWON iMeter APP for Android devices.

Scan to download the Android APP

For iPhone:

Search for "OWON iMeter" on the Apple App Store and click the icon to obtain and install the APP.

5.2. How to Connect with Mobile Device

  1. Download and install the free AC/DC clamp ammeter APP on your mobile device.
  2. Enable Bluetooth on your mobile device and open the "AC/DC clamp ammeter" APP.
  3. Turn on the AC/DC clamp ammeter. Press and hold the ZERO/★ button until the Bluetooth sign ★ appears in the upper left corner of the display.
  4. In the APP, click the "+" button in the upper left corner of the mobile device to add the AC/DC clamp ammeter.
  5. Enter the "Add Device" interface.
  6. Select the required AC/DC clamp ammeter from the "Available devices" list. You can also use the "Filter device" option to narrow down the list.
  7. After selecting the device, click it to enter the List of Devices.

Once connected, click the desired device in the List of Devices to enter the main use interface.

APP Function Table
CodeFunctionCodeFunction
DCDCDIODEDiode measurement
ACACCONTContinuity test
NCVNon-contact voltage measurementHzFrequency measurement
RESResistance measurementDUTYDuty cycle measurement
CAPCapacitance measurement
  • Add AC/DC clamp ammeter: Click the "+" soft key in the device list.
  • Select AC/DC clamp ammeter: Directly click the desired clamp ammeter in the device list.
  • Delete AC/DC clamp ammeter: In the device list, slide the device to the left and click "Delete".
  • Wireless control: In the device view, press or press and hold the Control button to operate the clamp ammeter remotely.
  • Custom AC/DC Clamp Ammeter Name: Click the ⚙ icon in the top right corner of the view interface, go to "More Settings", and click "Modify device name". Enter the custom name (digits, letters, and underline only) and save.
  • Voice broadcast: Click the ★ icon in the upper left corner of the single view interface or the ⚙ icon to enter More Settings to enable/disable voice broadcast.
  • Over-range alarm: In the settings interface, enable the alarm switch and set upper/lower limits. The APP will alert if the measured value is outside these limits.
  • Offline Recording Function: The APP can send a command to enable offline recording. The clamp ammeter will then disconnect and save measurement data internally. After recording, reconnect to the APP to read and save data as a CSV file. This is useful for long-term, unmanned recording. Ensure sufficient battery level before using.
  • Real-Time Data: Click the "Real-Time Data" button to enter the real-time data interface.
  • Read File: Click the "Read File" button to enter the document reading interface, where you can access offline and real-time data files.
  • Function Setting: Click the "Function Setting" button to enter the function setting interface, allowing you to configure data chart record interval, record count, auto-save, period, and theme.

6. Care and Maintenance

6.1. Regular Care and Maintenance

  • Use a damp cloth and gentle cleaning agents to clean the instrument housing. Avoid abrasive materials or solvents.
  • If any abnormality is found, immediately stop using the instrument and send it for repair.
  • All checks and repairs must be performed by qualified professional maintenance personnel.

6.2. Battery Replacement

Warning: Before opening the back cover, ensure the power supply is cut off and test probes are disconnected from any input ports or circuits.

When the low battery symbol ⚙ is displayed on the LCD, replace the built-in batteries immediately to maintain measurement accuracy. The battery specification is AAA 1.5V x 2 cells.

Diagram showing the back of the clamp ammeter with the battery cover removed, revealing two AAA batteries.

Figure 9: Battery Replacement

Operation Steps:

  1. Turn the function selection knob to the "OFF" position and remove the test probes from the input jacks.
  2. Unscrew the screw fixing the back cover with a screwdriver, remove the back cover, and then remove the old batteries.
  3. Replace with 2 new AAA 1.5V batteries.

7. Specifications

7.1. General Characteristics

  • Basic Conditions: Ambient temperature: 18℃~28℃; relative humidity: not more than 80%.
  • Note: During AC voltage/current and capacitance measurement, accuracy is within 5% to 100% range.
  • Maximum Reading: 19999
  • Frequency: (40-1000)Hz
  • Numerical Value Conversion Rate: 3 times/second
  • Automatic Range: Yes (Current excluded)
  • Opening Sizes: 17mm
  • True Virtual Value (True RMS): Yes
  • VFC: Yes
  • Numeric Data Retention: Yes
  • Zeroing Measurement: Yes
  • LCD Backlight: Yes
  • Automatic Shutdown: Yes
  • Buzzer ON/OFF: Yes
  • NCV function: Yes
  • Low-Voltage Indication: Yes
  • Input Protection: Yes
  • Input Impedance: ≥10MΩ
  • Over-Range Warning: Yes
  • Bluetooth Communication: CM2100B only
  • Dimensions: 182mm x 57mm x 32mm
  • Weight: 0.2KG
  • Operating Temperature: 0℃~50℃
  • Storage Temperature: -10℃~60℃
  • Relative Humidity: ≤80%
  • Altitude: Operating: 3,000 meters; Non-operating: 15,000 meters
  • DIY Supplies: Electrical
  • Certification: CE

7.2. Measurement Accuracy

FunctionRangeMinimum ResolutionAccuracy
DC Voltage (V)200.00mV0.01mV±(0.7%+10dig)
2.0000V0.0001V±(0.5%+5dig)
20.000V0.001V
200.00V0.01V
600.0V0.1V
AC Voltage (V)20.000V0.001VVRMS ±(0.8%+10dig)
VFC mode ±(4%+3)
200.00V0.01V
600.0V0.1V
DC Current (A)2.0000A0.001A±(2%+8dig)
20.000A0.01A±(2%+3dig)
100.00A0.1A
AC Current (A)2.0000A0.001A±(3%+10dig)
VFC mode ±(4%+10)
20.000A0.01A±(2.5%+5dig)
100.00A0.1A
Resistance (Ω)200.00Ω0.01Ω±(0.8%+10dig)
2.0000kΩ0.0001kΩ±(0.5%+10dig)
20.000kΩ0.001kΩ
200.00kΩ0.01kΩ
2.0000MΩ0.0001MΩ±(1%+10dig)
200.00MΩ0.01MΩ±(5.0%+10dig)
Capacitance (F)2.000nF0.001nF±(4.0%+10dig)
20.00nF0.01nF±(3.0%+10dig)
200.0nF0.1nF
2.000µF0.001µF
20.00µF0.01µF
200.0µF0.1µF
2.000mF0.001mF
20.00mF0.01mF
Frequency (Hz)200.00Hz0.01Hz±(0.1%+5dig)
2.0000kHz0.0001kHz
20.000kHz0.001kHz
200.00kHz0.01kHz
2.0000MHz0.0001MHz
20.000MHz0.001MHz
Duty Cycle (%)0.1%-99.9%0.1%±(1.2%+3dig)

8. Troubleshooting

This section addresses common issues you might encounter with your OWON CM2100/CM2100B clamp ammeter.

  • No Display or Faint Display:
    - Check battery level. If the low battery indicator ⚙ is on, replace the batteries (AAA 1.5V x 2).
    - Ensure the function knob is not in the "OFF" position.
  • Inaccurate Readings:
    - For current measurements, ensure only a single wire is clamped and it is centered within the clamp head (refer to Figures 4 and 5).
    - For DC current, ensure the ZERO button was pressed before measurement and the instrument's direction is consistent.
    - Check for low battery. Replace if necessary.
    - Ensure test leads are properly connected and undamaged.
    - Verify the correct function and range are selected for the measurement.
  • Bluetooth Connectivity Issues (CM2100B only):
    - Ensure Bluetooth is enabled on both the clamp ammeter (by holding ZERO/★ button until ★ appears) and your mobile device.
    - Make sure the mobile APP is installed correctly and is the latest version.
    - Check the distance between the clamp ammeter and your mobile device. The effective range is 7-8 meters, or up to 20 meters in open environments.
    - If the clamp ammeter has been inactive for 10 minutes, Bluetooth may have automatically turned off. Restart the device.
  • No Beep Sound:
    - Check if the buzzer function is enabled in the APP settings (if using CM2100B).
    - Ensure the instrument is not in a silent mode.
  • Over-Range Indication ("OL"):
    - The measured value exceeds the selected range. Switch to a higher range or use auto-ranging mode.
    - For current measurements, ensure the current does not exceed 100A.

Note: If you encounter persistent issues not covered here, please refer to the full user manual PDF available at www.owon.com.hk/download or contact customer support.

9. User Tips

  • For Small Current Tests: This multimeter is effective for measuring both AC and DC amps, even for small currents like those from a 5V fan, providing results consistent with other testers.
  • Accuracy: Users report acceptable and good accuracy, comparable to other reputable brands.
  • Bluetooth Connectivity: The Bluetooth feature (CM2100B) is generally easy to set up and connect with smartphones, enhancing usability.
  • Build Quality: The device has a pleasant case material and feels robust, contributing to a good user experience.
  • Portability: Its compact size makes it convenient for various applications.
  • Precision: Many users highlight its precision, making it a reliable tool for detailed measurements.

10. Warranty and Support

10.1. General Warranty

OWON warrants this product to be free from defects in materials and workmanship for a period of 1 year from the date of purchase by the original purchaser. This warranty is non-transferable and does not cover fuses, disposable batteries, misuse, alteration, neglect, or damage from abnormal operation or handling.

If the product is found defective during the warranty period, OWON will repair or replace it with new or reconditioned parts/products. All replaced items become the property of OWON.

To obtain service, notify OWON of the defect before the warranty period expires. The customer is responsible for packaging and shipping the defective product to the designated service center with proof of purchase.

This warranty does not cover damage from improper use, maintenance, unauthorized repairs, incompatible equipment connections, use of non-OWON supplies, or modifications that increase servicing difficulty.

10.2. Contact Information

For product support and service, please visit the OWON website or contact:

  • Web: www.owon.com.hk/download
  • Fujian LILLIPUT Optoelectronics Technology Co., Ltd.
    No. 19, Heming Road, Lantian Industrial Zone, Zhangzhou 363005 P.R. China
  • Tel: +86-596-2130430
  • Fax: +86-596-2109272
  • E-mail: info@owon.com.cn

11. Appendix: Included Accessories

The following accessories are included with your OWON CM2100/CM2100B Digital Clamp Ammeter:

  • Screwdriver x 1
  • Test pen x 1
  • User's Manual x 1 (This document)
  • Battery AAA1.5V x 2

The contents of this User's Manual are subject to change without prior notice.

© 2023 OWON. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?