1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the Sweideer LA155 Series Emergency Stop Push Button Switch. This industrial-grade switch is designed for safety applications, featuring a mushroom head, self-locking or self-resetting mechanisms, and optional integrated lighting. It is suitable for a wide range of industrial equipment, instrumentation, and CNC lathes.

Figure 1: Sweideer Emergency Stop Push Button Switch, highlighting thickened silver contacts and self-reset/self-locking features.
2. Product Overview
The LA155 Series offers various configurations, including different contact types (Normally Open, Normally Closed) and options for integrated lighting. The switches are designed for durability and ease of use in demanding environments.
Video 1: Product overview showcasing different types of Sweideer switches, their features, and robust construction.
3. Setup and Installation
The LA155 Series push button switches are designed for easy installation and flexible combination of contact modules.
3.1 Mounting
The switch requires a 22mm diameter opening for mounting. Ensure the mounting surface is clean and stable.

Figure 2: Dimensional drawing of the push button switch, showing a 22mm opening diameter and overall dimensions.
3.2 Contact Module Installation
The switch can accommodate 1 to 6 contact modules. These modules (Normally Open - NO and Normally Closed - NC) can be replaced and added as needed. The product base is made of PA66 material, ensuring reliable and compact arrangement.

Figure 3: Illustration of the easy installation and free combination of contact blocks for the switch.
3.3 Wiring Diagram
Refer to the following diagrams for proper wiring of the contact modules. Ensure all connections are secure and comply with local electrical codes.

Figure 4: Wiring diagram showing connections for FireWire L, Zero line N, and Load for both one normally open/one normally closed and two normally open/two normally closed configurations.
Contact Diagrams:

Figure 5: Diagrams illustrating the default and pressed states for 1NO1NC, 2NO, and 2NC contact types.
4. Operation
The LA155 Series switches offer both self-resetting and self-locking functionalities depending on the specific model.
4.1 Contact Functionality
- NO (Normally Open) Contact: In its normal (unpressed) state, the circuit is open (off). Pressing the button closes the circuit (powers on).
- NC (Normally Closed) Contact: In its normal (unpressed) state, the circuit is closed (on). Pressing the button opens the circuit (powers off).
4.2 Button Mechanisms
- Self-Reset: Once pressed, the button will reset and spring back to its original position as soon as the hand is released.
- Self-Locking: When pressed, the button locks into the depressed position. To release it, press the button again, and it will bounce back to its original state.

Figure 6: Close-up of an illuminated emergency stop button, demonstrating the solid color LED light source.
5. Maintenance
The Sweideer LA155 Series switches are designed for long-term reliability with minimal maintenance.
- Cleaning: Keep the button surface clean from dust and debris to ensure smooth operation. Use a soft, dry cloth for cleaning.
- Contact Inspection: The switches feature thickened silver contacts and copper-based composite contacts for enhanced durability and conductivity. Regular visual inspection for wear is recommended in high-usage environments.
- Environmental Protection: The switches offer IP65 waterproof protection (customized IP54 models also available), making them suitable for various industrial conditions.

Figure 7: Emergency stop button with details on IP65 waterproof rating and 22mm silver contact opening.
6. Troubleshooting
If you encounter issues with your push button switch, consider the following common troubleshooting steps:
- Switch Not Responding: Check all wiring connections to ensure they are secure and correctly installed according to the wiring diagram. Verify that the power supply is active.
- Button Stuck: For self-locking models, ensure the button is pressed firmly to engage or disengage the lock. For self-resetting models, check for any physical obstructions preventing the button from returning to its original position.
- Indicator Light Not Working: If your switch has an integrated light, check the voltage supply to the light and ensure the bulb (if replaceable) is not faulty.
7. Specifications

Figure 8: Detailed product parameters including electrical ratings and environmental conditions.
| Attribute | Value |
|---|---|
| Product Name | Emergency Stop Button |
| Product Model | LA155-B |
| Rated Insulation Voltage | AC660V 50Hz |
| Power Frequency Withstand Voltage | AC1890V |
| Rated Heating Current | 10A |
| Storage Temperature | -30°C ~ 70°C |
| Working Humidity | 45-85% RH |
| Ambient Temperature | -25°C ~ 55°C |
| Action Frequency | 1200 times/1 hour |
| Protection Level | IP54 (customized IP65) |
| Standards Met | IEC 60947/GB 14048.5 |
| Material | Plastic, Metal Base |
| Switch Type | Knob switch |
| Warranty | 1 Year |
| Certification | CE, CCC |
8. User Tips
- Visibility: The bright colors and clear design of the emergency stop button make it highly visible, which is crucial in emergency situations.
- Durability: Users have noted the robust and durable feel of the switch, suggesting it can withstand demanding industrial use.
9. Warranty and Support
The Sweideer LA155 Series Emergency Stop Push Button Switch comes with a 1-year warranty. For technical support or warranty claims, please contact your retailer or the manufacturer directly.

Figure 9: Certifications including CE, CCC, RoHS, UL, and SGS, demonstrating product compliance and quality.