Sweideer LA155-A1

Contents

Rotary Knob Switch User Manual

Model: LA155-A1 Series | Brand: Sweideer

1. Introduction

This manual provides instructions for the installation, operation, and maintenance of the Sweideer LA155-A1 Series Rotary Knob Switches. These switches are designed for industrial control applications, offering reliable performance with various contact configurations and operating modes.

Two Sweideer rotary knob switches, one with a key and one without, highlighting thickened silver contacts and self-reset/self-locking features.
Figure 1: Sweideer Rotary Knob Switches with key and standard knob, featuring thickened silver contacts.

2. Safety Information

WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel.

  • Always disconnect power before installing, wiring, or servicing the switch.
  • Ensure all wiring complies with local and national electrical codes.
  • Do not exceed the specified electrical ratings of the switch.
  • Verify proper insulation and grounding to prevent electrical hazards.
  • Use appropriate personal protective equipment (PPE) during installation and maintenance.

3. Product Features

The Sweideer LA155-A1 series switches are designed for durability and versatility:

  • Thickened Silver Contacts: Ensures reliable conductivity and extended lifespan.
  • Operating Modes: Available in Self-reset (momentary) and Self-locking (latching) types.
  • Position Options: Available in 2-position and 3-position configurations.
  • Key Switch Option: Provides enhanced security for critical operations.
  • Durable Construction: Features an aluminum alloy head for impact and oxidation resistance, and a flame-retardant plastic shell.
  • Standard Mounting: Designed for a 22mm mounting hole.
  • Environmental Resistance: Rated for IP40/IP65 protection against dust and water ingress.
Close-up of a Sweideer key switch, highlighting its aluminum alloy head for durability.
Figure 2: Aluminum alloy head for enhanced durability.
Icons representing product features: stable performance, high temperature resistant shell, energy saving material, complete specifications, and silver contact.
Figure 3: Key features of the Sweideer switches.

4. Specifications

Attribute Value
Model NumberLA155-A1
Brand NameSweideer
Item TypeSWITCHES
Switch TypeKey Switch
MaterialPlastic
Features2 Position, 3 Position, Momentary, Latching
Current Rating10A
Rated Insulation VoltageAC660V 50Hz
Power Frequency Withstand VoltageAC1890V
Rated Value (AC-15)36V/10A, 110V/10A, 220V/5A, 380V/2.7A, 660V/1.8A
Rated Value (DC-13)24V/4A, 48V/4A, 110V/2A, 220V/1A, 440V/0.6A
Conventional Thermal Current (1th)10A
Contact Resistance≤50mΩ
Insulation Resistance≥10mΩ
Mechanical Durability (Key Selector)≥5x10^4 times
Ambient Air Temperature-25°C ~ +40°C
Storage Temperature-30°C ~ 70°C
Altitude≤ 2000m
Relative Air Humidity≤90%
Pollution DegreeLevel 3
Protection GradeIP40/IP65 (customized IP65)
Action Frequency1200 times/1 hour
CertificationCE, CCC
EU LVD VoltageLow voltage: Below 50Vac or 75Vdc
Technical drawing with dimensions for the rotary knob switch, showing measurements like 22mm diameter and overall length.
Figure 4: Detailed dimensions of the switch components.

5. Components

Each Sweideer Rotary Knob Switch typically includes the following main components:

  • Knob/Key Head: The operating part, either a standard knob or a key-operated mechanism.
  • Mounting Base: Secures the switch to a panel.
  • Contact Modules: Electrical contacts (Normally Open - NO, Normally Closed - NC) that can be added or replaced. The switch can accommodate 1-6 contact modules.
  • Fixed Buckle: For securing contact modules.
  • Shock-absorbing Rubber Gasket: Provides sealing and stability.
Exploded view diagram of the rotary knob switch, showing individual components like the lock hole, matte texture, 22mm hole, shock-absorbing rubber gasket, shock nail holes, flame retardant shell, fixed buckle, thickened silver contact, and product information.
Figure 5: Exploded view of the switch components.

6. Installation

  1. Prepare Mounting Hole: Ensure the panel has a 22mm diameter hole for mounting the switch.
  2. Disassemble: Carefully separate the knob/key head assembly from the contact module base.
  3. Mount Head: Insert the knob/key head through the 22mm hole from the front of the panel.
  4. Secure: From the back of the panel, attach the mounting base and tighten the securing nut to hold the switch head firmly in place.
  5. Attach Contact Modules: Connect the desired NO (Normally Open) and/or NC (Normally Closed) contact modules to the switch base using the fixed buckle mechanism. Ensure they are securely fastened.
  6. Wiring: Proceed with wiring the contact modules as per the wiring diagrams in Section 8.

7. Operation

The LA155-A1 series switches offer different operating characteristics:

7.1 Contact Types

  • NO (Normally Open) Contact: In its default state, the circuit is open (off). Turning the knob or key closes the circuit (powers on).
  • NC (Normally Closed) Contact: In its default state, the circuit is closed (on). Turning the knob or key opens the circuit (powers off).

7.2 Operating Mechanisms

  • Self-locking (Latching) Type: When the knob/key is turned, it locks into position, maintaining the circuit state. To change the state, turn the knob/key again, and it will return to its original position.
  • Self-reset (Momentary) Type: When the knob/key is turned, it activates the circuit. Upon releasing the knob/key, it automatically springs back to its original position, returning the circuit to its default state.
Diagram illustrating the difference between a self-reset button (rotates and lets go) and a self-locking button (autogiration bomb).
Figure 6: Self-reset vs. Self-locking operation.

8. Wiring Diagrams

Proper wiring is crucial for the correct function of the switch. Refer to the diagrams below for common contact configurations.

Detailed wiring diagram showing NO (normally open) and NC (normally closed) contact points on the switch modules. Includes tables for 1NO1NC, 2NO, and 2NC contact types, illustrating their default status and press status with circuit diagrams.
Figure 7: Product wiring display and contact type diagrams.

Contact Function Analysis:

Diagram showing two contact modules. One is labeled 'Press power on to select normally on' (green) and the other 'Press power off to select normally closed' (red).
Figure 8: Contact module function analysis.

9. Maintenance

  • Regular Inspection: Periodically check the switch for any signs of wear, damage, or loose connections.
  • Cleaning: Keep the switch surface clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid using abrasive cleaners or solvents.
  • Contact Check: If experiencing intermittent operation, inspect the contact modules for proper seating and cleanliness.
  • Environmental Conditions: Ensure the switch operates within its specified ambient temperature and humidity ranges to prevent premature failure.

10. Troubleshooting

Problem Possible Cause Solution
Switch does not activate/deactivate circuit. No power, incorrect wiring, faulty contact module, or mechanical issue. Check power supply. Verify wiring against diagrams. Inspect/replace contact module. Check for obstructions.
Key is difficult to insert or turn. Misalignment, debris in keyway, or incorrect key. Ensure key is aligned correctly. Clean keyway if necessary. Confirm you are using the correct key for the switch.
Switch feels loose or wobbly. Loose mounting nut or damaged panel. Tighten the mounting nut. If the panel is damaged, consider reinforcing or replacing it.

11. User Tips

  • When integrating into an electrical panel, ensure the 22mm mounting hole is precisely cut for a secure fit.
  • For key switches, always ensure the key is properly aligned before attempting to insert or turn to prevent damage to the lock mechanism.
  • The modular design allows for easy replacement of contact blocks if needed, extending the life of the switch.

12. Frequently Asked Questions

Q: What is the maximum power rating this switch can handle?
A: The switch has a conventional thermal current of 10A. For AC-15, it can handle up to 220V/5A or 380V/2.7A. For DC-13, it can handle up to 24V/4A or 48V/4A. Always refer to the detailed specifications for specific voltage and current ratings.
Q: Can I use this switch for both momentary and latching applications?
A: Yes, the LA155-A1 series includes models for both self-reset (momentary) and self-locking (latching) operations. Ensure you select the correct type for your application.
Q: Is the switch waterproof?
A: The switch has a protection grade of IP40/IP65. IP65 offers protection against dust and low-pressure water jets from any direction. Please check the specific model's rating for your environment.

13. Warranty and Support

This Sweideer product comes with a 1-year warranty from the date of purchase, covering manufacturing defects. For technical support, troubleshooting assistance, or warranty claims, please contact your vendor or the manufacturer directly.

A detailed user manual in PDF format is also available for download: View User Manual (PDF).

© 2024 Sweideer. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.