1. Introduction
The ATORCH DL24/DL24P is a versatile electronic load tester designed for measuring battery capacity and DC power. It features a 2.4-inch HD color screen, Bluetooth connectivity for data transmission, and supports various testing modes. This manual provides detailed instructions for setup, operation, maintenance, and troubleshooting to ensure optimal performance and safe use of your device.
2. Specifications
General Specifications
| Feature | Description |
|---|---|
| Brand Name | ATORCH |
| Model Number | DL24 |
| Type | Household Battery Tester |
| DIY Supplies | Electrical |
| Certification | CE, RoHS |
| Battery Included | No |
| Hign-concerned Chemical | None |
| Origin | Mainland China |
Performance Parameters
| Parameter | Value |
|---|---|
| Voltage Range | 2~200V |
| Current Range | 0.2~20A |
| Power Range (DL24) | 0~150W |
| Power Range (DL24P) | 0~180W |
| Fan Working | Intelligent control, turns on when powered, stops during standby, starts during operation. |
| Fan Turn OFF | Set standby time; in OFF state, when standby time is reached, it stops. |
| CC Test Mode | Constant current |
| CV Test Mode | Constant voltage |
| CP Test Mode | Constant power |
| CR Test Mode | Constant resistance |
| PC Computer Connection | Supported, via data cable or Bluetooth |
| Electronic Load Wiring | Supports 2-wire testing or 4-wire testing |
| Protection Function | Over-current, Over-power, Over temperature protection |
| Product Power Supply | DC5.5-12V/USB-5V/2A/QC/PD 12V power supply |
Physical Dimensions
| Dimension | Value |
|---|---|
| Length | 20 cm |
| Width | 18 cm |
| Height | 10 cm |
| Weight | 0.668 kg |
DL24 vs DL24P Difference
The primary difference between the DL24 and DL24P models lies in their maximum power handling capabilities:
| Feature | DL24 150W | DL24P 180W |
|---|---|---|
| Load Power (Max) | U x I ≤ 150W | U x I ≤ 180W |
| Load Voltage | 2-200V | 2-200V |
| Load Current | 0-20A | 0-20A |
| Max Testable Power (<36V) | 150W | 150W |
| Max Testable Power (36V-80V) | 60W | 60W |
| Max Testable Power (80V-200V) | 45W | 45W |
Note: This product will be updated at any time; please pay attention to the web page description for detailed update details.

3. Setup
3.1. Product Overview and Interfaces
Familiarize yourself with the key interfaces and components of the electronic load tester.

- Fan: Starts when powered on, stops during standby, and starts during operation.
- Product Power Supply Input Port: (12V/1A)
- Bluetooth Symbols: Indicates Bluetooth status.
- Four Testing Modes: Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR), Constant Power (CP).
- Positive/Negative Pole of Battery: A+ / V+ for positive, A- / V- for negative.
- Test Inputs: DC5.5, Mini USB, Micro USB, Type-C.
- External Temperature Probe Interface: For connecting an external temperature sensor.
- Limited Time Discharge: Setting for discharge duration (00:01-99:59 hour/minute).
- Cut Off Voltage Setting: Configurable voltage threshold to stop discharge.
- Built-In Bluetooth: For APP connectivity.
- System Speaker: Provides audio feedback.
- PC Online Connection Interface: For connecting to a computer.
- Set Button: Short press to navigate, long press for detailed input mode introduction.
- Button +/-: For adjusting values.
- Integrated Discharge Tube Temperature Display: Shows internal temperature.
- Start Button (ON/OFF): Short press to start/stop, long press to access system background.
- Battery Internal Resistance Test: Functionality for testing internal resistance.
- External Temperature Display: Shows temperature from external probe.
3.2. Powering the Electronic Load
The product does not include a power adapter. It can be powered by one of three methods:
- DC5.5-12V Power Supply: Insert into the device's DC5.5 interface.
- USB-5V/2A Charger Power Supply: Insert into the device's CC port.
- QC/PD Protocol 12V Charger Power Supply: Insert into the device's CC port.
Attention: A DC12V power supply is required for the device to function correctly.

NOTES on Load Power:
- Load power (W) = Voltage (U) x Current (I) ≤ 150W/180W (max).
- Observe the power testing range to avoid product damage:
- Voltage < 36V: Maximum testable power of 150W.
- Voltage > 36V, < 80V: Maximum testable power of 60W.
- Voltage > 80V, < 200V: Maximum testable power of 45W.
3.3. Wiring Methods
The electronic load supports two wiring methods: 2-wire and 4-wire. Choose the method appropriate for your testing needs.

- Two-wire wiring method: This method is relatively simple and convenient. Connect to the 2 terminals [A+] and [A-].
- Four-wire wiring method: This method ensures more accurate voltage measurement as it is not affected by the voltage drop of the wire. It is recommended for users with a basic understanding of circuits for more precise measurements.
3.4. Included Accessories
The following accessories are typically included in the package and can be used directly:
- Measuring Line Adapter Board: Used to test DC power supply, Mini USB, Type-C, and Android USB data cables.
- Temperature Probe: Measures battery temperature and the temperature of various devices.
- 10A 2-wire Test Cable: For detecting batteries or other 10A wiring equipment within range.
- Computer Online Cable: Connects the tester to a computer for online software use, firmware upgrades, and data reading.




3.5. Optional Accessories (Ordered Separately)
- Load Fast Charging Protocol High Voltage Trigger Test Board: Supports PD3.1, PD3.0, QC, AFC, FCP protocols. Triggers 5V/9V/12V/15V/20V/28V fast charging voltage for aging, testing, and quality identification.
- 20A Large Battery Four-Wire Battery Activity Testing Fixture: Uses a 4-wire wiring system for more accurate testing of various lithium and dry batteries (e.g., 18650, 26650, 14500, 16340, 26850, 18350, 32650, 46950, A, AA, AAA, 2032, GPA76, LR44).
- Battery Test Box: For 4-wire wiring system testing of 18650, 26650, 14505, 14340, 14250 batteries.



4. Operation
4.1. Main Functional Testing Interface
The device's display shows various parameters depending on the selected test mode. The startup screen displays the ATORCH logo.

4.2. Test Instructions for Each Mode
The DL24/DL24P offers four main testing modes:
| Test Mode | Operation Instructions |
|---|---|
| Constant Current (CC) Mode | Select 'CC' mode. Set the desired current value, cut-off voltage, and discharge parameters. Press 'OK/Start' to begin constant current discharge. |
| Constant Voltage (CV) Mode | Select 'CV' mode. The tested power supply needs to be a constant current power supply. The device will operate at the set voltage value. Note: Constant Voltage mode cannot test batteries. |
| Constant Power (CP) Mode | Select 'CP' mode. The device automatically calculates the current-to-voltage ratio and works at the set power value. Can be combined with a high-voltage trigger to test charger maximum power. Note: Constant Power mode cannot test batteries. |
| Constant Resistance (CR) Mode | Select 'CR' mode. The device automatically calculates the current based on the set resistance value, maintaining a constant resistance for discharge. |
4.3. PC Computer Online Functions
Connect the DL24/DL24P to a PC via a HID data cable to read device current, voltage, power, capacity, and other data. Data can be exported as an XLS table.
- PC Software Download: Download PC Software (ZIP)
- Supported OS: Windows 7 and Windows 10 or above.
4.4. Bluetooth APP Functions
The Bluetooth APP allows you to read device current, voltage, power, capacity, and other data, and export XLS table data. The APP is primarily for controlling switches and may have compatibility issues. For primary testing, use the PC software.
- Android APP: Search 'E-test' on Google Play. Direct Android APP Download (APK)
- iOS APP: Search 'E_test' on the iPhone APP Store.
- Alternative APP Download: E-meter APP on Mediafire
- Supported Versions: Android 5.0 and above.
Important Notes for APP Use:
- When connecting online, ensure GPS positioning permission is enabled.
- Some phones (e.g., Samsung) may have incompatible apps. If issues arise, try another phone for pairing and online connection.
Bluetooth Connection Steps:
- Ensure the USB tester is powered on and its Bluetooth indicator is flashing.
- Turn on Bluetooth on your phone.
- Open the E-test APP.
- Click the Bluetooth icon in the upper left corner of the APP to open the menu.
- Select your USB tester model (DL24-BLE) from the list.
- The Bluetooth icon in the APP will turn blue, indicating a successful online connection.
4.5. System Settings Navigation
To access system settings:
- Press and hold the 'OK/Start' button from the measurement interface to return to the menu options interface.
- Short press the '+'/'-' button to navigate to the 'System Settings' icon (it will turn green).
- Short press again to enter the system settings interface.
- Use the '+'/'-' buttons to select columns and enter parameters for corresponding functions.

5. Maintenance
- Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Avoid using liquids or abrasive cleaners.
- Fan Operation: The fan is designed to operate intelligently. Ensure the fan is not obstructed to allow for proper cooling during operation. If the fan is not working during an active test, refer to the troubleshooting section.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
6. Troubleshooting
6.1. Alarm Functions
The device includes several protection functions to prevent damage:
- Overload Power Protection (OPP!): Triggers if power exceeds 150.0W.
- Over-Current Protection (OCP!): Triggers if current exceeds 25.00A.
- MOS Tube Temperature Over Protection (OTP!(Mos)): Triggers if MOS tube temperature exceeds 100.0°C.
- External Temperature Probe Alarm Protection (OTP!(Ext)): Triggers if external temperature exceeds 28.5°C.
6.2. Software Related Issues
- APP crashes on PC: Ensure you download and test the PC software for compatibility before purchase. The PC software only supports Windows 7 and 10 or above.
- Bluetooth Connection (BLE vs SPP): The APP uses the latest connection technology (BLE for mobile, SPP for PC). Do not attempt to pair in your phone's Bluetooth settings. Instead, connect directly through the E-test APP by clicking the Bluetooth symbol and selecting 'DL24-BLE'.
- Incompatible Phones: Some phones (e.g., Samsung) may have compatibility issues with the APP. If you encounter problems, try using a different phone for pairing and online connection.
- Computer Pairing Password: The default pairing password is '0000' or '1234'.
6.3. Common Issues
- Fan not working: The fan operates intelligently, turning on during active discharge and off during standby. If the fan is not working during an active test where heat is being generated, check for obstructions or contact support.
- Inaccurate readings: Ensure proper wiring, especially for high-precision measurements where the 4-wire method is recommended. Calibrate the device if necessary (refer to system settings).
- Power supply issues: Ensure the power supply meets the DC12V requirement for the device to work correctly.

7. User Tips
- The device is highly useful when combined with the PC software for detailed data analysis and logging.
- While the device is robust, consider using it on a flat, isolated surface, especially since it does not come with a full enclosure. The plastic feet provide sufficient clearance.
- Be aware that the device is a dummy load with a counter; it does not charge batteries.
- The device is precise in measuring V, A, W, and Wh. It can handle up to 25A and 185W for short durations, maintaining stability at 150W around 80-85°C.
- The fan always spins when the device is on (even at low speed) and increases to maximum speed when current exceeds 10A or temperature rises.
- Carefully remove any rubber bands holding the screen during unboxing.
8. Warranty and Support
For detailed warranty information and technical support, please refer to the official product page or contact the seller directly. A comprehensive user manual in PDF format is available for download: