Introduction
Thank you for choosing the HLTNC HS320 Variable Frequency Drive. This manual provides essential information for the correct installation, operation, and maintenance of your frequency converter. Please read this manual carefully before use to ensure safe and efficient operation.
For a complete reference, you may also consult the official user manual PDF: HLTNC HS320 User Manual (PDF).
Safety Precautions
WARNING: Failure to follow these safety precautions may result in serious injury or equipment damage.
- Before wiring, ensure the input power is OFF.
- All wiring must be performed by professional electricians.
- The grounding terminal MUST be properly grounded.
- After completing emergency stop circuit wiring, verify its effectiveness.
- Do not connect the output line of the frequency converter directly to the housing. Avoid short-circuiting the output line.
- Confirm that the AC main circuit power supply voltage matches the rated voltage of the converter.
- Do not perform voltage resistance tests on the frequency converter.
- Connect the brake resistor according to the provided wiring diagram.
- Do not connect the power cord to the output terminals U, V, and W.
- Do not connect a contactor to the output circuit.
- Ensure the protective housing is installed before powering on. Disconnect power before removing the housing.
- Do not place the frequency converter with reset retry function near mechanical equipment, as it may restart suddenly when an alarm stops.
- The converter will only alarm and reset after the running signal is cut off. If it alarms and resets while the running signal is active, the frequency converter may start unexpectedly.
- Do not touch the terminals when powered on; high voltage is present and is very dangerous.
- Do not change wiring or disassemble terminals while the power is on.
- Inspection and maintenance must only be carried out after the main circuit power supply is cut off.
- Do not modify the frequency converter without permission.
Product Overview
The HLTNC HS320 is a Variable Frequency Drive (VFD) designed for controlling the speed of CNC spindles and other motor applications. It features a digital tube display, a rotary knob for speed control, and various function keys.
Components and Features



The VFD features a detachable control panel, allowing for remote monitoring and easier operation. The panel includes a digital display, a rotary knob for speed control, and buttons for programming (PRG/SET), jogging/escape (JOG/ESC), running (RUN), and stopping/resetting (STOP/RES).
Product Video
Technical Data
The HLTNC HS320 series offers various models with different power ratings and input voltages. Below are the detailed specifications for the frequency converter and recommended braking resistors.
Rated Data of Frequency Converter

| Model | Power | Input Power | Output Current (A) | Dimensions L×W×H (mm) | Mounting Size L×W - Mounting Screws (mm) |
|---|---|---|---|---|---|
| 0.4S1-220V | 0.4KW | Single-phase AC 200V-240V 50Hz/60Hz | 2.1 | 170×79×127 | 160×60.5-M5 |
| 0.75S1-220V | 0.75KW | 3.8 | |||
| 1.5S1-220V | 1.5KW | 7 | 187×86×144 | 173×68-M4 | |
| 2.2S1-220V | 2.2KW | 9.0 | |||
| 3.0S1-220V | 3.0KW | 13 | 216×101×151 | 204×83.5-M4 | |
| 4.0S1-220V | 4.0KW | 15 | 237×111×168 | 221×93.5-M5 | |
| 5.5S1-220V | 5.5KW | 20 | |||
| 0.4S3-220V | 0.4KW | Three-phase AC 200V-240V 50Hz/60Hz | 2.1 | 170×79×127 | 160×60.5-M5 |
| 0.75S3-220V | 0.75KW | 3.8 | |||
| 1.5S3-220V | 1.5KW | 7 | 187×86×144 | 173×68-M4 | |
| 2.2S3-220V | 2.2KW | 9.0 | |||
| 3.0S3-220V | 3.0KW | 13 | 216×101×151 | 204×83.5-M4 | |
| 4.0S3-220V | 4.0KW | 15 | 237×111×168 | 221×93.5-M5 | |
| 5.5S3-220V | 5.5KW | 20 | |||
| 0.4G3-380V | 0.4KW | Three-phase AC 340V-440V 50Hz/60Hz | 1.5 | 170×79×127 | 160×60.5-M5 |
| 0.75G3-380V | 0.75KW | 2.1 | |||
| 1.5G3-380V | 1.5KW | 3.8 | 187×86×144 | 173×68-M4 | |
| 2.2G3-380V | 2.2KW | 5.1 | |||
| 3.0G3-380V | 3.0KW | 7.1 | 216×101×151 | 204×83.5-M4 | |
| 4.0G3-380V | 4.0KW | 9.0 | 237×111×168 | 221×93.5-M5 | |
| 5.5G3-380V | 5.5KW | 12.6 | |||
| 7.5G3-380V | 7.5KW | 16.1 | 237×111×168 | 221×93.5-M5 | |
| 11.0G3-380V | 11.0KW | 25.0 | 249×143×172 | 237×130-M5 |
Selection of Braking Resistor
| Model | Power | Input Power | Power of Braking | Resistance Value of Braking Resistor |
|---|---|---|---|---|
| 0.4S1-220V | 0.4KW | Single-phase AC | 100 W | 250 Ω |
| 0.75S1-220V | 0.75KW | 100 W | 200 Ω | |
| 1.5S1-220V | 1.5KW | 200V-240V 50Hz/60Hz | 300 W | 100 Ω |
| 2.2S1-220V | 2.2KW | 300 W | 100 Ω | |
| 4.0S1-220V | 4.0KW | 1000 W | 75 Ω | |
| 5.5S1-220V | 5.5KW | 1000 W | 75 Ω | |
| 0.4S3-220V | 0.4KW | Three-phase AC 200V-240V 50Hz/60Hz | 100 W | 250 Ω |
| 0.75S3-220V | 0.75KW | 100 W | 200 Ω | |
| 1.5S3-220V | 1.5KW | 300 W | 100 Ω | |
| 2.2S3-220V | 2.2KW | 300 W | 100 Ω | |
| 4.0S3-220V | 4.0KW | 500 W | 75 Ω | |
| 5.5S3-220V | 5.5KW | 1000 W | 75 Ω | |
| 0.4G3-380V | 0.4KW | Three-phase AC 340V-440V 50Hz/60Hz | 100 W | 750 Ω |
| 0.75G3-380V | 0.75KW | 100 W | 750 Ω | |
| 1.5G3-380V | 1.5KW | 300 W | 400 Ω | |
| 2.2G3-380V | 2.2KW | 300 W | 250 Ω | |
| 4.0G3-380V | 4.0KW | 500 W | 150 Ω | |
| 5.5G3-380V | 5.5KW | 800 W | 100 Ω | |
| 7.5G3-380V | 7.5KW | 1000 W | 75 Ω | |
| 11.0G3-380V | 11.0KW | 1200 W | 50 Ω |
Installation and Wiring
Proper installation and wiring are crucial for the safe and reliable operation of the frequency converter. Refer to the following diagrams and terminal descriptions.
Wiring Diagram

Purpose of the Terminals
| Terminal | Purpose | Design Description |
|---|---|---|
| R, S, T | Converter power supply | For 380V converters, connect to R, S, T. For 220V converters, connect to R, S or R, T (according to terminal label). Use an air switch as overcurrent protection. If a leakage protection switch is used, select one with sensitivity >200mA and operation time >100ms to prevent misoperation. |
| U, V, W | Converter output, to connect the motor | To reduce leakage current, the motor connection line should not exceed 50 meters. |
| PE | Grounding | Frequency converter must be well grounded. |
| X1 | Digital input X1 | Factory default: forward (F5.02). |
| X2 | Digital input X2 | Factory default: reverse (F5.03). |
| X3 | Digital input X3 | Factory default: multi-speed first (F5.04). |
| X4 | Digital input X4 | Factory default: multi-speed second (F5.05). |
| X5 | Digital input X5 | Factory default: external reset signal input (F5.06). |
| GND | Signal common terminal | Zero potential of input and output signal. |
| AVI | 0-10V signal input | 0-10V. |
| 10V | Power supply for frequency setting potentiometer | +10V, 10mA Max. |
| ACI | 4-20 mA analog input | 4-20mA. |
| AO | Analog output signal | Set by parameter F6.10. |
| TA, TB, TC | Relay output | Contact capacity: AC 250V/3A, DC 24V/2A. Set by parameter F5.07. |
Commissioning and Operating
This section details how to operate the control panel and configure basic running parameters.
Operation Panel and Method

- Parameter Setting Key (PRG/SET): Used to read and modify parameters. Press to enter the parameter group or display the parameter value.
- Jog and Return Key (JOG/ESC): Used for jog operation of the frequency converter or to return from parameter setting.
- Run Key (RUN): In panel mode, used to start the frequency converter.
- Stop Key (STOP/RES): In panel mode, used to stop the frequency converter.
- Speed Control Knob: Adjusts the output frequency.
- Value Change Keys (Up/Down Arrows): Used to change parameter values.
Method of returning to the original interface after setting parameters:
- Power off and then power on again.
- Select parameter d-00 and press SET.
- Long press the SET key.
Setting the Run Command Mode
The run command mode is configured via parameter F0.02. There are two primary modes:
- Panel Control Start-Stop Mode (F0.02=0, factory default):
To operate, press the green RUN button on the panel to start and the red STOP button to stop. The converter defaults to forward run. Forward or reverse run can be set via input terminals X1-X5 (reverse setting is 4).
- Terminal Control Start-Stop Mode (F0.02=1):
Operation is controlled by external terminals. Refer to the wiring diagrams for two-wire and three-wire control modes.

Figure 7: Two-wire control mode 1 (Parameters: F0.02=1). Connect X1 to GND to run forward and cut to stop. Connect X2 to GND to run reversely and cut to stop. 
Figure 8: Three-wire control mode 1 (Parameters: F0.02=1, F5.04-5, F5.00-2). This mode allows for forward, reverse, and stop control via external signals.
Selection of Frequency Setting Mode
The frequency setting mode is configured via parameter F0.03:
- F0.03=4: Running frequency set by potentiometer (keyboard potentiometer).
- F0.03=2: Running frequency input by AVI (0-10V external potentiometer).
- F0.03=3: Running frequency input by ACI (4-20mA).
- F0.03=1: Controlled by external terminal (switching value for increasing/decreasing frequency).
Parameter Tables
The frequency converter has extensive parameters organized into groups (F0, F1, F2, etc.) for various functions such as basic running, V/F control, vector control, auxiliary running, digital input/output, analog input/output, program running (PLC), PID control, motor parameters, and protection settings.
Due to the extensive nature of these tables, please refer to the full PDF manual for a complete list and detailed descriptions of all parameters and their settings. The PDF manual can be found here: HLTNC HS320 User Manual (PDF).
Key parameter groups include:
- Group F0 - Basic running parameters: Control mode, run command selection, frequency sources.
- Group F1 - V/F control parameter: V/F curve settings, torque lift, carrier frequency.
- Group F2 - Vector control parameter: Velocity loop, motor slip compensation, current loop.
- Group F3 - Auxiliary running parameters: Starting mode, braking current/time, stop mode.
- Group F4 - Auxiliary running parameters 2: Jog frequencies, acceleration/deceleration times, hopping frequencies.
- Group F5 - Digital input and output parameters: Terminal function settings (X1-X5, Relay R).
- Group F6 - Analog input and output functions: AVI/ACI input settings, AO output settings.
- Group F7 - Program running parameters (PLC): Multi-speed frequencies and running times.
- Group F8 - PID parameters: PID control characteristics, given quantity selection, feedback, bias, sleep control.
- Group F9 - Motor parameter setting: Rated power, voltage, current, frequency, stator/rotor resistance.
- Group FA - Protection parameter setting: Overload protection, undervoltage/overvoltage protection, current limiting.
- Group Fb - Display and special parameter setting: Monitoring parameters, fault history, software version.
- Group FP - Factory parameter setting: Factory password.
- Group d - Monitoring parameters: Real-time display of output frequency, voltage, current, motor speed, etc.
Troubleshooting
This section provides a list of common fault codes, their possible causes, and recommended countermeasures to help resolve issues with your frequency converter.
| Fault Code | Name | Possible Causes | Countermeasures |
|---|---|---|---|
| OU1 (1) | Overvoltage in accelerated running | Abnormal input voltage; Restart the motor in rotation | Check the input power supply; Change the setting to start after DC braking |
| OU2 (2) | Overvoltage in decelerated running | Deceleration time is too short; Abnormal input voltage | Extend deceleration time; Check the input power supply |
| OU3 (3) | Overvoltage in constant speed running | Abnormal input voltage | Check the input power supply |
| OCC1 (4) | Hardware acceleration overcurrent | Acceleration time is too short; The power of frequency converter is small; Improper setting of V/F curve or torque lift; The IGBT module is damaged | Extend acceleration time; Choose a frequency converter with a large power; Adjust the V/F curve or torque lift; Contact the supplier for help |
| OCC2 (5) | Hardware deceleration overcurrent | Deceleration time is too short; The power of frequency converter is small; The IGBT module is damaged | Extend deceleration time; Choose a frequency converter with a large power; Contact the supplier for help |
| OCC3 (6) | Hardware constant speed overcurrent | The grid voltage is low; The load is mutated or abnormal; The power of frequency converter is small; The IGBT module is damaged | Check the input power supply; Check the load or reduce load mutation; Choose a frequency converter with a large power; Contact the supplier for help |
| OCS1 (7) | Overcurrent in software accelerated running | Acceleration time is too short; The power of frequency converter is small; Improper setting of V/F curve or torque lift | Extend acceleration time; Choose a frequency converter with a large power; Adjust the V/F curve or torque lift |
| OCS2 (8) | Overcurrent in software decelerated running | Deceleration time is too short; The power of frequency converter is small; The grid voltage is low | Extend deceleration time; Choose a frequency converter with a large power; Check the input power supply |
| OCS3 (9) | Overcurrent in software constant speed running | The load is mutated or abnormal; The power of frequency converter is small | Check the load or reduce load mutation; Choose a frequency converter with a large power |
| EFO (10) | Power module fault | Converter transient overcurrent; The control board is abnormal or seriously disturbed | See overcurrent countermeasures; Contact the factory for help |
| OU (11) | Overvoltage during shutdown | Abnormal input voltage | Check the voltage of power supply |
| OU3 (12) | Constant speed overvoltage | The voltage of power supply is too high; The load is mutated or abnormal | Check whether the voltage of power supply is too high; Check the load or reduce load mutation |
| LU (13) | Undervoltage | Abnormal input voltage; Relay failed to pull in | Check the voltage of power supply; Contact the factory for help |
| OH (14) | Over-temperature | The ambient temperature is too high; The space around the frequency converter is small; The air duct is blocked; The cooling fan is not running | Improve the environment; Adjust the space; Clean and clear the air duct; Check the power supply of the fan and the fan itself |
| OL1 (15) | Converter overload | Improper setting of V/F curve or torque lift; The grid voltage is too low; Acceleration time is too short; The motor is overloaded | Adjust the V/F curve and torque lift; Check the grid voltage; Extend acceleration time; Choose a more powerful frequency converter |
| OL2 (16) | Motor overload | Improper setting of V/F curve or torque lift; The grid voltage is too low; Locked rotor or load mutation is too large; Motor overload protection factor is not set correctly | Adjust the V/F curve and torque lift; Check the grid voltage; Check the load; Set the motor overload protection factor correctly |
| BIAS (17) | Current bias error | Hardware failure | Contact the supplier for help |
| CBC (18) | Cycle-by-Cycle current liming fault | The power of frequency converter is small; The load is mutated or abnormal | Choose a frequency converter with a large power; Check the load or reduce load mutation |
| FBL (19) | Low PID feedback lower limit value | PID feedback line is loose; The feedback quantity is less than the disconnection detection value | Check the feedback line; Adjust the detection input threshold |
| FBH (20) | PID feedback exceeds the upper limit | When the PID feedback quantity is greater than the feedback overvalue detection value, and the duration is longer than the PID feedback overvalue detection time, the frequency converter alarms the fault FBH | Check the feedback line; Adjust the detection input threshold |
| EEEP (21) | EEPROM reading/writing error | EEPROM fault | Contact the factory for help |
| CE (22) | Dual CPU communication failure | CPU communication failure | Contact the factory for help |
| EF (23) | External equipment fault | External device fault input terminal is closed | Disconnect the external device fault input terminal and clear the fault (check the cause) |
| EPA (24) | Parameter setting failure | ||
| E485 (25) | Communication disconnection | Check whether the communication line is well connected and whether the line sequence is correct. | |
| SFOC (27) | Software overcurrent | Adjust acceleration/deceleration time; Motor parameters do not match, restart parameter identification; | |
| ELH | Water shortage fault | ||
| SPO | Output phase-loss fault | The wiring from the converter to motor is not normal; The three-phase output of the frequency converter is unbalanced | Troubleshoot wiring problems; Check whether the three-phase winding of the motor is normal |
| EPA1 | Parameter setting error | The three-wire function of the converter is not set correctly | Check whether the three-wire system of the converter terminal is set correctly |
| SLEP | Sleep mode | The frequency converter goes into sleep mode |
User Tips
- Initial Setup: Some users have noted that initial setup can be challenging. Take your time to carefully review the parameter tables and wiring diagrams. If you encounter difficulties, refer to the detailed parameter descriptions in the full manual.
- Controller Integration: For advanced applications like CNC, consider how the VFD integrates with your main controller (e.g., OpenBuilds BlackBox 32). Ensure compatibility and proper signal mapping for digital and analog inputs/outputs.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your HLTNC HS320 VFD. Always observe safety precautions during maintenance.
- Power Disconnection: All inspection and maintenance procedures must be performed only after the main circuit power supply has been completely cut off and sufficient time has passed for internal capacitors to discharge (typically 10 minutes after power-off).
- Environmental Checks: Regularly check the operating environment for excessive temperature, dust, and humidity. Ensure proper ventilation and clear any obstructions from the air ducts and cooling fan.
- Terminal Connections: Periodically inspect all terminal connections for tightness and signs of corrosion. Loose connections can lead to intermittent operation or faults.
- Protective Housing: Ensure the protective housing is always securely installed during operation to prevent accidental contact with live parts and to protect against environmental factors.
- Cleaning: Keep the VFD clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
Warranty and Support
The warranty period for this product is twelve months from the date of delivery. During this period, faults occurring under normal use and according to usage requirements will be covered.
Circumstances Not Covered by Warranty:
- Violation of use requirements.
- Damage due to human causes (e.g., improper handling, incorrect wiring).
- Damage from natural disasters or flooding.
- External damage or operation in a bad environment.
- Unauthorized disassembly, modification, or maintenance of the frequency converter.
If the product was purchased from a distributor or agent, please contact them directly for support or in case of any fault.
Please retain this manual for future reference and in case of need for warranty claims.
Ref. No.: XM-H0123 | Completed in July 2021
Frequently Asked Questions (FAQ)
- Q: Can this VFD be connected to an OpenBuilds BlackBox 32 controller?
- A: Yes, it is generally possible to connect this VFD to a CNC controller like the OpenBuilds BlackBox 32. This typically involves wiring the VFD's control terminals (digital inputs X1-X5, analog inputs AVI/ACI, and relay outputs TA/TB/TC) to the corresponding output pins on your CNC controller. You will need to configure the VFD parameters (e.g., F0.02 for terminal control, F0.03 for frequency setting via analog input) and the CNC controller's firmware to ensure proper communication and control. Consult the wiring diagram in this manual and the documentation for your specific CNC controller for detailed connection instructions.