Tuya Tuya WIFI Gas Sensor

Contents

Tuya Wi-Fi Gas Leak Detector User Manual

Model: Tuya WIFI Gas Sensor

Brand: Tuya

1. Introduction

This product is designed to detect explosive gases such as natural gas and LPG (Liquefied Petroleum Gas) in the air for homes, offices, and similar environments. In the event of a gas leak, the device will sound an alarm with a voice prompt, send a text notification to your mobile device, and can drive a valve/manipulator to shut off the gas source.

It also functions as a fire alarm, equipped with a built-in heat sensor that responds when the ambient temperature increases due to fire. Users can monitor gas levels and temperature remotely via a mobile application, requiring a Wi-Fi 802.11 b/g/n (2.4GHz) network connection. The TFT color LCD screen displays the current date and time, gas level, temperature, and remaining sensor life.

2. What's in the Box

  • Gas leak detector x1
  • USB Cable x1
  • Mounting adhesive tape x1
  • Screws x2
  • User guide x1

3. Product Overview (At a Glance)

Familiarize yourself with the components and indicators of your gas leak detector:

Front view of Tuya Wi-Fi Gas Leak Detector showing the screen and indicator lights.

Figure 1: Front view of the detector.

  • Red alarm indicator: Lights up during a gas leak or heat alarm.
  • Yellow fault indicator: Lights up if the sensor is faulty.
  • Green power indicator: Indicates the device is powered on and operating correctly.
  • Yellow life indicator: Lights up when the sensor life is over.
  • Display screen: Shows gas levels, temperature, time, and status.
  • USB+5V power port: For connecting the power cable.
  • Wi-Fi configuration/Clock adjustment/Test/Silence button: Multi-function button for setup and control.

Rear View:

Rear view of the detector showing mounting bracket and sockets.

Figure 2: Rear view of the detector with mounting bracket and sockets.

  • Middle socket: For manipulator connection.
  • Right socket: For valve control.
  • Bracket: For mounting the device.

Indicator Meanings:

IndicatorWhat you seeWhat it means
PowerGreenPower is OK
AlarmBlinking redGas leak or heat alarm
FaultBlinking yellowSensor is fault
LifeBlinking yellowSensor life is over

4. Setup

4.1. Installation Location

Do not install the detector in the following locations:

  • Where the temperature is below $0^{\circ}C$ or above $+55^{\circ}C$.
  • Near exhaust fans, vaporous areas, chimney hoods, or places with strong odors.
  • Too close to apertures or ventilation channels, as strong air currents can reduce gas concentration detection.

Recommended Installation Locations:

  • For Natural Gas (lighter than air): Install the detector approximately 30 cm below the ceiling and 1.5-4 meters away from the gas supply.
  • For LPG (Liquefied Petroleum Gas, heavier than air): Install the detector approximately 30 cm above the floor and 1.5-4 meters away from the gas supply.
Diagram showing recommended installation locations for gas detectors relative to gas stoves and ceilings/floors.

Figure 3: Installation location guidelines.

4.2. Mounting the Detector

You can mount the detector using either screws or adhesive tape:

  1. Using screws: Screw the provided bracket to the ceiling or wall. Align your detector with the bracket and turn it clockwise to secure it.
  2. Using adhesive tape: Peel off one side of the double-sided adhesive tape and stick it to the underside of the detector. Then, peel off the other side and attach the detector to a clean, flat surface.

4.3. App Setup and Wi-Fi Configuration

To connect your detector to your smartphone, follow these steps:

  1. Download the App: Scan the QR code provided in the manual or search for "Smart Life" in Google Play Store (Android) or Apple App Store (iOS). Install the application.
  2. Register/Log In: Open the Smart Life app and register a new account or log in if you already have one.
  3. Add Device (Smartlink/EZ Mode - Recommended):
    • Tap "Add Device" or the "+" icon, then select "Security & Sensors" from the categories.
    • Choose "Gas Detector (Wi-Fi)".
    • Enter your local Wi-Fi network name (SSID) and password. Ensure your Wi-Fi is 2.4GHz, as 5GHz networks are not supported.
    • Power off your detector. Press and hold the multi-function button, then power on the detector. Do not release the button until the screen displays "Smart Mode, Connecting".
    • In the app, confirm the indicator is blinking (fast flashing). Wait for the configuration to complete.
    • Once connected, you can rename your detector in the app and tap "Done".
  4. Add Device (Soft AP Mode - If Smartlink Fails):
    • Power off your detector. Press and hold the multi-function button, then power on the detector. Do not release the button until the screen displays "Smart Mode, Connecting".
    • Press the button again; the screen should now display "AP Mode, Connecting".
    • In the app, tap the top right icon to switch to "AP Mode", then confirm the indicator is blinking (slow flashing).
    • Tap "Confirm > Go to Connect". Your phone will open Wi-Fi settings. Connect to the Wi-Fi hotspot named "Smartlife-XXXX" (where XXXX are unique characters).
    • Return to the Smart Life app and wait for the Wi-Fi configuration to finish.

For a visual guide on the setup process, please watch the following video:

Video: Demonstrates the setup and testing of the gas leak detector.

5. Operating Instructions

5.1. Warm-up

After powering on, the detector will enter a warm-up phase for approximately 180 seconds. The screen will display "Waiting" along with a countdown ticking sound. During this time, the sensor is stabilizing and may not detect accurately.

5.2. Display Information

The screen cycles through different information displays every minute:

Detailed view of the LED display showing life, time, network temperature, fuselage temperature, date, and gas concentration.

Figure 4: Detailed view of the LED display.

  • Wi-Fi Icon: A dot indicates connection to the network. Gray indicates offline. No icon means Wi-Fi module failure.
  • Life: Displays remaining sensor life in days. A fault is shown if the sensor is faulty.
  • Time & Date: Current time and date.
  • Gas Concentration: Shows the detected gas level in %LEL (Lower Explosive Limit).
  • Temperature: Displays the ambient temperature.

5.3. Gas Leak Alarm

When a gas leak is detected:

  • The display screen will show the gas level and "There is a gas leak. Check now".
  • As the gas level rises and reaches the preset alarm threshold (6%LEL), the detector will sound an alarm, and the red alarm indicator will flash.
  • A voice prompt will announce "Emergency. There is a gas leak. Don't use any electrical switches and naked flames. Get out and call for help now".
  • A notification "Gas leak detected" will be pushed to your mobile device.
  • If connected, the device can activate a valve/manipulator to shut off the gas source.
Display showing '006 %LEL Gas leak detected'.

Figure 5: Gas leak detection display.

5.4. Heat Alarm

If the ambient temperature around the detector increases to the preset value ($57^{\circ}C$):

  • The red alarm indicator will flash.
  • The display screen will show the temperature and "Heat alarm. Check now".
  • A text notification will be pushed to your mobile device.

5.5. Silence Function

In case of an alarm, you can mute the alarm sound by clicking the multi-function button on the device or tapping the silence icon in the Smart Life app. The screen will display "Alarm has been hushed" with a voice prompt.

5.6. Clock Adjustment

The date and time are usually updated automatically via the network when the detector is connected to Wi-Fi. If not, you can adjust them manually:

  • Without an active alarm, press and hold the multi-function button until the date and time setting window appears.
  • The digits will increase automatically. Click the button to select the digit you want to adjust, and the screen will move to the next digit.
  • Once all date and time digits are entered and are green, the screen will display "Long click to save". Press and hold the button until you hear a tone to save the settings.
  • If no action is taken for 30 seconds, the detector will exit the adjustment mode, and any changes will not be saved.

6. Maintenance

6.1. If Sensor is Faulty

If the sensor malfunctions, the yellow fault indicator will flash, and "Fault" will be displayed on the screen. In this case, the device may need servicing or replacement.

6.2. Testing the Detector

It is recommended to test your detector regularly to ensure proper functioning:

  • Without an active alarm, click the multi-function button on the device or tap the test function in the Smart Life app.
  • The screen will display "Ready for test", and you will hear "This is a mere test. We'll alarm a sound. The alarm is loud. The test starts".
  • The detector will then perform a self-test, checking for low-level gas leaks, high-level gas leaks, heat alarms, and valve/manipulator control.
  • Upon completion, the screen will show "Test finished. Please reset valve". If the test is successful, "The test is finished. Everything is OK" will be heard, and a text notification will be sent to your mobile.
  • If the sensor fails the test, you will hear "The sensor failed. Check now", and your mobile will receive a corresponding notification.

7. Troubleshooting

  • Device not connecting to Wi-Fi: Ensure your Wi-Fi network is 2.4GHz, not 5GHz. Check Wi-Fi password accuracy. Try Soft AP mode if Smartlink fails. Ensure the device is within Wi-Fi range.
  • No power: Verify the USB cable is securely connected to the detector and the power adapter, and that the adapter is plugged into a working power outlet. This device requires constant power via USB.
  • False alarms: Ensure the detector is not installed in areas with strong odors, excessive steam, or near exhaust fans (refer to Installation Location).
  • Sensor fault indicator (yellow blinking): If the sensor is faulty, perform a test. If the fault persists, the sensor may need replacement or professional servicing.
  • No app notifications: Check your phone's notification settings for the Smart Life app to ensure notifications are enabled. Verify the detector is connected to Wi-Fi and the internet.

8. Specifications

FeatureSpecification
Power SupplyMicro USB +5V/1A
Average Consumption1.5W (<200mA)
Detecting GasNatural gas (CH4), LPG
Working Temperature-10 to $55^{\circ}C$
Working Humidity<95%RH (non-condensing)
Gas Sampling MethodDiffusion
Gas Detection Range0-100%LEL
Alarm Density6%LEL (CH4)
Alarm Tolerance±3%LEL
Response Time≤ 30 seconds
Heat Alarm Value$57^{\circ}C$
Alarm Sound≥70dB/m
Alarm IndicationIndicator, sound, voice prompt, APP notification push
Valve/Manipulator Output12V/300mA output for 15 seconds
Warm-up Time180 seconds
Sensor Life5 years
Wi-Fi Standard802.11 b/g/n (2.4GHz)
MaterialABS plastic
Dimensions86x86x24.5mm

9. User Tips

  • Power Source: This device requires continuous power via its USB connection; it does not operate on batteries. Ensure it is always plugged into a reliable power source.
  • RV Use: The detector can be used in recreational vehicles (RVs) for gas leak detection, provided it has a stable 2.4GHz Wi-Fi connection and a continuous 5V USB power supply.
  • Regular Testing: Perform the self-test function regularly (e.g., monthly) to ensure the sensor and alarm system are working correctly.
  • Placement: Pay close attention to the installation guidelines for natural gas (near ceiling) versus LPG (near floor) to ensure optimal detection.

10. Safety Considerations and Warnings

  • Avoid Interference: Vapors from alcohol, sprays, intense cigarette smoke, torch gas, cleaning agents, strong odors, and excessive meal/water vapors can cause false alarms or malfunction.
  • Accident Reduction: This product is designed to reduce the risk of accidents but cannot guarantee complete prevention. It is a safety aid, not a substitute for vigilance.
  • Proper Use: Always use the detector as instructed. Pay attention to safety and security in your daily life, and do not solely rely on the detector for gas safety.
  • Electrical Switches: In case of a gas leak alarm, do NOT use any electrical switches or open flames. Immediately ventilate the area and contact emergency services.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the seller's terms of service or contact the point of purchase. Keep your proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.