1. Introduction
The ATORCH AT085 is a compact and versatile Type-C digital display voltage ammeter power meter designed for testing various Type-C digital devices. It provides real-time measurements of voltage, current, power, and capacity, and supports advanced features like PD3.1 protocol testing, real-time curve display, and gravity-sensing screen rotation. This manual provides essential information for the safe and effective use of your AT085 device.
Figure 1: ATORCH AT085 CC Tester, highlighting 50V, 12A (short-term peak), 600W capabilities, curve lock screen, gravity sensing, and PD3.1 support. Features a durable metal aluminum shell.
2. Safety Information
Please read and understand all safety instructions before using the AT085. Failure to follow these instructions may result in electric shock, fire, or damage to the device or connected equipment.
- Do not disassemble or modify the device.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight.
- Keep the device away from water and other liquids.
- Use the device within its specified voltage and current ranges to prevent damage.
- Ensure proper connection of Type-C cables to avoid short circuits.
3. Product Overview
The AT085 features a clear digital display and intuitive controls. Below is an overview of its main components and interface.
Figure 2: Interface Function Diagram of the ATORCH AT085.
3.1. Interface Components
- C Male Input/Output: Connects to the power source (e.g., charger) or device being charged.
- C Female Input/Output: Connects to the device being tested (e.g., phone, laptop).
- Up/In/Back Button: Used for navigation and settings.
- Down/Zero/Confirm Button: Used for navigation, resetting values, and confirmation.
- Data Display Area: TFT screen showing real-time measurements and curves.
Figure 3: Key features of the ATORCH AT085, including PD3.1 recording, alloy shell, real-time electrical parameter curve, gravity induction rotary screen, bidirectional current detection, battery capacity calculation, and support for multiple fast charging protocols.
4. Specifications
The ATORCH AT085 offers precise measurements and robust performance:
| Parameter | Value |
|---|---|
| Model Number | AT085 |
| Working Voltage | DC 4.5~50V |
| Working Current | 0~6A (short-term peak 12A) |
| Power Display | 0~600W |
| Energy Display | 0~9999WH |
| Capacity Display | 0~99999mAh |
| Self Power Consumption | <0.15W |
| Sampling Resistor | 0.001R |
| Accuracy Class | 1% (Software calibration technique) |
| Data Retention Period | TA=55°C 20 years |
| Operating Temperature | 0~45°C / 32~113°F |
| Dimensions | 43mm*25mm*10mm |
| Display Type | Digital Only (TFT Color Screen) |
| Screen Size | 0.85 inch |
| Backlight Adjustment | Yes |
| G-Sensor | Yes (for screen rotation) |
| Screen Shutdown Function | Yes |
| Button Mode | Double key button |
| Peak Recording | Current, voltage, and power Peak recording |
| Certification | CE |
Figure 4: Accuracy evaluation of AT085 against professional instruments, showing high precision for voltage and current measurements.
5. Setup
The AT085 is designed for plug-and-play operation. Follow these steps to begin testing:
- Connect Power Source: Plug the C Male input/output of the AT085 into your Type-C power source (e.g., wall charger, power bank).
- Connect Device: Plug the C Female input/output of the AT085 into the Type-C port of the device you wish to test (e.g., smartphone, tablet, laptop).
- Power On: The meter will automatically light up and display measurements once a load protocol is detected and voltage is output from the charger.
Important Notice: When using a USB-C port charger, the meter will only light up for display when both the charger and the mobile phone are connected simultaneously.
Figure 5: The AT085 connected to various Type-C devices for testing.
6. Operating Instructions
6.1. Button Functions
- Up/In/Back Button:
- Short Press: Scrolls up through display pages or adjusts values in settings.
- Long Press: Enters settings menu or returns to the previous function. (Warm tip: Long pressing this button on the first two display pages will turn the screen black and white.)
- Down/Zero/Confirm Button:
- Short Press: Scrolls down through display pages or adjusts values in settings.
- Long Press: On different pages, long press to select capacity Zero, curve pause, confirmation, or zero no-load current.
- Quick Press (5 times): Quickly pressing this key five times will lock or unlock the screen display direction (gravity sensing).
6.2. Display Modes and Features
- Real-time Data: The main display shows voltage (U), current (I), power (P), and accumulated energy (E) or capacity (Wh/mAh).
- Real-time Curve Display: The AT085 can display real-time voltage and current curves, allowing for analysis of fluctuations during charging. This feature can be paused by long-pressing the Down/Zero/Confirm button.
- Gravity Sensing: The screen display direction automatically rotates based on the device's orientation. This can be locked/unlocked by quickly pressing the Down/Zero/Confirm button five times.
- PD3.1 Protocol Testing: The device supports testing for various fast charging protocols, including PD2.0, PD3.0, PPS, QC2.0, QC3.0, FCP, SCP, AFC, PE, DASH VOOC, and SuperVOOC. It is compatible with future PD3.1 48V high-voltage protocols.
- Peak Recording: The AT085 records peak values for current, voltage, and power.
- Battery Capacity Calculation: The device can estimate battery capacity.
Figure 6: Real-time voltage and current curve display on the AT085.
Figure 7: AT085 displaying PD3.1 compatibility and supported fast charging protocols.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Avoid Impact: While the device features a durable metal aluminum shell, avoid dropping or subjecting it to strong impacts.
8. Troubleshooting
8.1. Frequently Asked Questions
- Question 1: Why does the product not display when plugged into the charger separately?
- Answer: The Type-C port of most chargers defaults to no voltage output when no load is connected. The AT085 will only display when a load protocol is detected and the charger outputs voltage. Ensure both the charger and a device are connected.
- Question 2: Why can't the test meter measure 10A or 120W on my product charger?
- Answer: The values displayed by this product are real-time charging parameters during the charging process. The parameters marked on the charger are typically the maximum possible power parameters, and the charger may not always output such large parameters in real-time, depending on the connected device's requirements.
- Question 3: Why does it occasionally display a current of 0.01-0.02A when the output is not connected to a load?
- Answer: This product uses bidirectional current detection, and a small no-load current reading is a normal phenomenon. This can be reset by quickly touching the current reset interface three times (using the Down/Zero/Confirm button).
9. User Tips
Based on user feedback, here are some helpful tips for using your AT085:
- The device is very compact and portable, making it convenient for on-the-go testing.
- The display is bright and clear, with a high refresh rate for real-time data.
- Despite its small size, the graphic display for voltage/current curves is functional and useful for analysis.
- It provides comprehensive information, including max values and battery capacity estimation, which users find very helpful.
- The device is generally considered easy to use.
10. Warranty and Support
For detailed warranty information and customer support, please refer to the official product documentation or contact your retailer. A user manual in PDF format is available for download and further reference:
User manual (PDF): View PDF Manual