1. Introduction
This manual provides essential information for the safe and effective operation of your OWON DGE1000 Series Single-Channel Arbitrary Waveform Generator. Please read this manual thoroughly before use and keep it for future reference.
The OWON DGE1000 series offers a 3.6-inch LCD display, frequency output up to 60MHz, and a sample rate of up to 300MSa/s. It supports various waveform outputs and modulation functions, making it a versatile tool for electrical testing and development.

Front view of the OWON DGE1000 Series Arbitrary Waveform Generator, showing the display and control panel.
2. General Safety Requirement
Before any operations, please read the following safety precautions to avoid any possible bodily injury and prevent this product or any other products connected from damage. In order to avoid any contingent danger, this product is only used within the range specified.
- Check the input power supply Settings according to the power supply voltage standards in your country.
- Only the qualified technicians can implement the maintenance.
- To avoid Fire or Personal Injury:
- Use Proper Power Cord. Use only the power cord supplied with the product and certified to use in your country.
- Product Grounded. This instrument is grounded through the power cord grounding conductor. To avoid electric shock, the grounding conductor must be grounded. The product must be grounded properly before any connection with its input or output terminal.
- Check all Terminal Ratings. To avoid fire or shock hazard, check all ratings and markers on the instrument. Refer to the user's manual for more information about ratings before connecting the instrument. Do not exceed any of ratings defined in the following section.
- Do not operate without covers. Do not operate the instrument with covers or panels removed.
- Use Proper Fuse. Use only the specified type and rating fuse for this instrument.
- Avoid exposed circuit. Do not touch exposed junctions and components when the instrument is powered.
- Do not operate if in any doubt. If you suspect damage occurs to the instrument, have it inspected by qualified service personnel before further operations.
- Use your instrument in a well-ventilated area. Inadequate ventilation may cause an increasing of temperature or damages to the instrument. Please keep the instrument well ventilated, and inspect the air outlet and the fan regularly.
- Do not operate in wet conditions.
- Do not operate in an explosive atmosphere.
- Keep instrument surfaces clean and dry.
- BNC output ports not allowed to input any signal such as voltage, current and other electrical signal, otherwise, it will be burned.
3. Safety Terms and Symbols
Safety Terms in this Manual:
- Warning: Indicates conditions or practices that could result in injury or loss of life.
- Caution: Indicates conditions or practices that could result in damage to this product or other property.
Safety Terms on the Product:
- Danger: Indicates an injury or hazard may immediately happen.
- Warning: Indicates an injury or hazard may be accessible potentially.
- Caution: Indicates a potential damage to the instrument or other property might occur.
Safety Symbols on the Product:
- ⚠ Hazardous Voltage
- ⎔ Refer to Manual
- ⏚ Protective Earth Terminal
- ⏚ Chassis Ground
- ⏚ Test Ground
4. General Inspection
After receiving your new generator, it is recommended that you perform the following checks:
- Check for damage caused by transportation: If the packaging carton or foam plastic protection cushion shows serious damage, do not discard it until the device and its accessories have passed electrical and mechanical property tests.
- Check the Accessories: Refer to the 'Accessories' section of this manual to verify all items are present and undamaged. If any accessory is missing or damaged, contact your distributor or local office.
- Check the Complete Instrument: If the instrument appears damaged, does not work normally, or fails performance tests, contact your distributor or local office. Keep the packaging if damage was caused by transportation.

Image showing the accessories included in the package: Host Machine, BNC to Alligator Clip, USB Cable, USB to DC Cord, Power Adapter, Quick Guide, and Packaging.
5. Quick Start
Front Panel Overview

Angled view showing the display and controls of the waveform generator.
| No. | Component | Description |
|---|---|---|
| 1 | LCD | Displays the user interface. |
| 2 | Menu selection keys | 5 keys to activate corresponding menus. |
| 3 | Operation keys | Mode: output the modulated waveform. |
| 4 | Knob | Changes selected values, selects arbitrary waveform types and data file names. |
| 5 | Direction key | Moves the cursor of the selected parameter. |
| 6 | Utility | Sets utility functions. |
| 7 | Power button | Turns the waveform generator on/off. |
| 8 | Number keypad | Inputs parameters. |
| 9 | Output terminal | Outputs channel signal. |
| 10 | On/Off button | Turns the output of the channel on or off. Backlight indicates status. |
| 11 | Waveform Selection area | Includes Sine, Square, Ramp, Pulse, Noise, Arbitrary Wave. |
Rear Panel Overview

Rear view of the waveform generator showing ports and power input.
| No. | Component | Description |
|---|---|---|
| 1 | Air vents | Ensures proper ventilation for the device. |
| 2 | Power connector | DC power input connector. |
| 3 | Foot Stool | Tilts the signal generator for easy operation. |
| 4 | USB Device interface | Used to connect a USB type B controller. Can be connected with PC, the signal generator can be controlled by the host computer software. |
Power On
- Connect the instrument to the AC power using the DC power adapter provided.
- Press the power button on the front panel. The backlight of the power channel switch will light up, and the buzzer will sound.
Warning: To prevent electric shock, make sure the instrument is properly grounded.
User Interface
The user interface displays channel name, load, current modulation mode, and indicators for USB Host connection. It also features menu titles, current waveform/mode settings, and parameters like frequency/period, amplitude/high level, offset/low level, and phase.

Close-up of the 3.6-inch LCD display showing waveform output and menu settings.
6. Panel Operation
Channel Setting
Press the On/Off button on the front panel to turn on/off the corresponding channel output. The backlight of the button will light up when it is set to output.
Waveform Setting
Sine, square, ramp, pulse, noise, or arbitrary waves can be set and output. Press the waveform selection button on the front panel to choose the desired waveform type. The waveform parameters can be set via the menu on the right.
Output Sine Wave
Press the Sine waveform selection button. The screen displays the user interface for the sine wave. Parameters such as Frequency/Period, Amplitude/High Level, Offset/Low Level, and Phase can be adjusted using the menu selection buttons and the knob or numeric keypad.
Output Square Wave
Press the Square waveform selection button. The screen displays the user interface for the square wave. Parameters such as Frequency/Period, Amplitude/High Level, Offset/Low Level, and Phase can be adjusted.
Output Ramp Wave
Press the Ramp waveform selection button. The screen displays the user interface for the ramp wave. Parameters such as Frequency/Period, Amplitude/High Level, Offset/Low Level, Phase, and Symmetry can be adjusted.
Output Pulse Wave
Press the Pulse waveform selection button. The screen displays the user interface for the pulse wave. Parameters such as Frequency/Period, Amplitude/High Level, Offset/Low Level, Phase, Width/Duty, Rise, and Fall can be adjusted.
Output Noise Wave
The noise wave generated is white noise with a bandwidth of 20MHz. Parameters such as Amplitude/High Level and Offset/Low Level can be adjusted.
Output Arbitrary Wave
Press the Arbitrary waveform selection button. The screen displays the user interface for the arbitrary wave. Parameters such as Frequency/Period, Amplitude/High Level, Offset/Low Level, Phase, Built-in, and Store can be adjusted.

Display showing arbitrary waveform selection (DC, AbsSine, AmpALT, NegRamp, SineTra) and modulation modes (AM, FM, PM, FSK), and sweep function.
Generate Sweep (Sweep)
In sweep mode, the generator varies its output from a start frequency to a stop frequency within a specified sweep time. Sweep can be generated by Sine, Square, Ramp, or Arbitrary waves (except DC). The sweep type can be Linear or Logarithmic.
Generate Burst (Burst)
Burst pulse train can produce various waveform functions. Burst can last for a certain number of waveform cycles (N-Cycle Burst) or be continuous. Burst can apply to Sine, Square, Ramp, Pulse, and Arbitrary waveforms (except DC).
Output the Modulated Waves
Supported modulation types include AM (Amplitude Modulation), FM (Frequency Modulation), PM (Phase Modulation), and FSK (Frequency Shift Keying). Press the Mode function key to select the modulation type and enter the setup menu.
Utility Function Setting
Press the Utility function key to enter the utility menu. You can set parameters such as display settings, channel settings, and system settings. Press Utility again to exit the utility menu.
- Display Settings: Adjust Brightness Control (0-100%) and Screen Saver (On/Off, time range 1-999 minutes).
- Channel Settings: Set the load value (1Ω to 10kΩ).
- System Settings: Change Language, Beeper (On/Off), and USB Device Type (PC/USBTMC).
- Restore to Factory Setting: Reset all settings to default.
- Firmware Update: Use the rear-panel USB port to update firmware via a USB memory device.
7. Communication with PC
The DGE1000 Series supports communication with a computer via a USB port. Using the Waveform Editor software installed on the computer, you can control the signal generator, write files to it, and save instrument settings.
- Set USB device protocol type: Press Utility → System → USB Dev, switch to PC.
- Connection: Connect the USB Device interface on the rear panel of the signal generator to the USB interface of the computer with a USB cable.
- Install the driver: Run Waveform Editor software on the computer and follow instructions to install the driver. The driver path is typically in the USBDRV folder within the Waveform Editor software directory.
- Host computer communication port setting: Open the Waveform Editor software, click "Communications" in the menu bar, select "Ports-Settings", and choose "USB" as the communication port. A green connection status prompt indicates success.
Video demonstrating various measurement functions of an OWON multimeter, including DC/AC voltage, current, resistance, continuity, diode test, capacitance, frequency, temperature, MAX/MIN/average, and relative value measurements, as well as data recording and PC connectivity.
8. Troubleshooting
- The screen is still black and there is no display after pressing the power switch:
- Check whether the power is connected correctly.
- Check that the voltage selector is in the correct gear.
- Check whether the fuse below the power connector meets the specified type and rating and is in good condition.
- Restart the instrument. If the problem persists, contact us for service.
- The measured value of the output signal amplitude does not match the displayed value:
- Check whether the actual load value of the signal is consistent with the load value set in the instrument. Refer to 'Channel Settings' in the 'Panel Operation' section.
If you encounter other problems, please try to restart the instrument. If it still cannot work properly, please contact us for service.
9. Specifications
All technical specifications are guaranteed when the following conditions are met, unless otherwise stated:
- The signal generator must be operated continuously for more than 30 minutes at the specified operating temperature (20°C to 30°C).
- The signal generator is in the calibration internal and has performed a self-calibration.

Table of product specifications for models DGE1030 and DGE1060, detailing channel, frequency output, sample rate, vertical resolution, waveform types, frequency range, stability, amplitude, DC offset, load impedance, and modulation types.
Waveforms
| Parameter | DGE1030 | DGE1060 |
|---|---|---|
| Bandwidth | 30 MHz | 60 MHz |
| Sample Rate | 125 MSa/s | 300 MSa/s |
| Vertical Resolution | 14 bits | |
| Channel | 1 | |
| Standard Waveforms | Sine wave, square wave, ramp wave, pulse wave, noise | |
| Arbitrary Waveforms | Sinc, exponential rise, exponential decline, electrocardiogram, Gaussian, semi-positive, Lorentz, dual audio, DC voltage totaling more than 160 kinds | |
Frequency Characteristics
| Waveform | DGE1030 | DGE1060 |
|---|---|---|
| Sine wave | 1 μHz ~ 30MHz | 1 μHz ~ 60MHz |
| Square wave | 1 μHz ~ 15MHz | 1 μHz ~ 20MHz |
| Pulse wave | 1 μHz ~ 15MHz | 1 μHz ~ 20MHz |
| Ramp wave | 1 μHz - 1 MHz | 1 μHz - 2 MHz |
| Noise wave (-3 dB) | 20 MHz BW(AWGN) | |
| Arbitrary wave | 1 μHz - 10 MHz | |
| Frequency resolution | 1 μHz or 7 significant figures | |
| Frequency stability | ±30 ppm at 0±40°C | |
| Frequency aging rate | ±30 ppm per year | |
Amplitude Characteristics
| Parameter | DGE1030 | DGE1060 |
|---|---|---|
| Output amplitude (into 50Ω Load) | 1mVpp - 10Vpp (≤10MHz) 1mVpp - 4Vpp (≤30MHz) | 1mVpp - 10Vpp (≤10MHz) 1mVpp - 4Vpp (≤60MHz) |
| Output amplitude (high resistance) | ±(10 Vpk - Amplitude Vpp/2) (≤10MHz) ±(4Vpk - Amplitude Vpp/2) (≤30MHz) | ±(10 Vpk - Amplitude Vpp/2) (≤10MHz) ±(4Vpk - Amplitude Vpp/2) (≤60MHz) |
| DC Offset Range (AC+DC) | ±(5 Vpk - Amplitude Vpp/2) (≤10MHz) ±(2 Vpk - Amplitude Vpp/2) (≤30MHz) | ±(5 Vpk - Amplitude Vpp/2) (≤10MHz) ±(2 Vpk - Amplitude Vpp/2) (≤60MHz) |
| DC Offset Resolution | 1mV or 4 digits | |
| Load Impedance | 50Ω (Typical) | |
| DC Offset Accuracy | ±(1% of |setting| + 1 mV + Amplitude Vpp * 0.5%) | |
Modulation Characteristics
| Modulation Type | Description |
|---|---|
| AM, FM, PM, FSK | Comprehensive modulation functions |
| Internal modulation frequency | 2 mHz to 100 kHz |
| Depth (AM) | 0.0% to 100.0% |
| Phase deviation (PM) | 0° to 180° |
| FSK rate | 2 mHz to 1MHz |
Sweep Characteristics
| Parameter | Value |
|---|---|
| Sweep Time | 1 ms to 500 s ± 0.1% |
| Sweep Type | Linear, logarithmic |
| Trigger source | Internal, manual |
Burst Characteristics
| Parameter | Value |
|---|---|
| Types | N-cycle |
| N-cycle trigger source | Internal, manual |
| Periodicity | 1 ~ 60000 (Max = Burst Period / Period) / infinite |
Input/Output Characteristics
| Parameter | Value |
|---|---|
| Communication Interface | USB Device |
General Specifications
| Parameter | Value |
|---|---|
| Display type | 3.6-inch color LCD display |
| Display resolution | 480 Horizontal x 272 Vertical pixels |
| Display color | 65536 colors, 16 bits, TFT |
| Voltage | DC 5V / 2A |
| Power consumption | Less than 10W |
| Working temperature | 0°C to 40°C |
| Storage temperature | -20°C to 60°C |
| Relative humidity | Less than 35°C: ≤ 90% relative humidity 35°C to 40°C: ≤ 60% relative humidity |
| Height | Operating 3,000 meters Non-operation 12,000 meters |
| Dimension (L×H×W) | 200mm × 68.5mm × 73.6mm |
| Weight | Approx. 0.5 kg |
| Adjustment interval | The recommended calibration interval is one year |
10. Accessories
The following accessories are included with your OWON DGE1000 Series Arbitrary Waveform Generator:
- 1 × BNC to alligator cable
- 1 × USB cable
- 1 × USB to DC cable
- 1 × Power adapter
- 1 × Quick Guide
- 1 × Packaging
11. General Care and Cleaning
General Maintenance
Do not store or leave the instrument where the liquid crystal display will be exposed to direct sunlight for long periods of time.
Caution: To avoid any damage to the instrument or probe, do not expose it to any sprays, liquids, or solvents.
Cleaning
Inspect the instrument and probes as often as operating conditions require. To clean the instrument exterior, perform the following steps:
- Wipe the dust from the instrument and probe surface with a soft cloth. Do not make any scuffing on the transparent LCD protection screen when cleaning the LCD screen.
- Disconnect power before cleaning your instrument. Clean the instrument with a wet soft cloth not dripping water. It is recommended to scrub with soft detergent or fresh water. To avoid damage to the instrument or probe, do not use any corrosive chemical cleaning agent.
Warning: Before powering on again for operation, it is required to confirm that the instrument has already been dried completely, avoiding any electrical short circuit or bodily injury resulting from the moisture.
12. Warranty and Support
General Warranty
The product is warranted to be free from defects in materials and workmanship for a period of 2 years from the date of purchase by the original purchaser. Accessories such as probes and batteries have a 12-month warranty. This warranty is non-transferable.
If the product is found defective during the warranty period, the company will either repair or replace it free of charge. Replaced parts become the property of the company.
To obtain service, notify the company of the defect before the warranty period expires. The customer is responsible for packaging and shipping the defective product to the designated service center, along with proof of purchase.
This warranty does not cover defects, failures, or damage caused by improper use, inadequate maintenance, unauthorized repairs, or modifications.
For product support, visit: www.owon.com.hk/download
You can also refer to the official user manual PDF for more detailed information: OWON DGE1000 Series User Manual (PDF)
Contact Information
Fujian LILLIPUT Optoelectronics Technology Co., Ltd.
No. 19, Heming Road
Lantian Industrial Zone, Zhangzhou 363005 P.R. China
Tel: +86-596-2130430
Fax: +86-596-2109272
Web: www.owon.com.cn
E-mail: info@owon.com.cn