PowMr POW-PSTAR

Contents

PowMr Pstar Series Solar Charge Controller User Manual

Models: Pstar-30A, Pstar-60A, Pstar-80A

1. Introduction

Thank you for choosing the PowMr Pstar Series of Solar Power Controllers. This controller features numerical control technology design, an LCD display, and automatic operation. Its Pulse-Width Modulation (PWM) type battery charging mode, along with advanced control technology, significantly extends battery life.

This controller is designed for independent solar energy systems, automatically managing the charging and discharging processes. The battery charging and discharging processes are optimized to prolong battery life and enhance system performance. Built-in self-test and electronic protection functions prevent controller damage from installation errors and system failures.

The Pstar series solar controller package includes one controller and a user manual. It is versatile, compact, and lightweight, delivering up to 80A charging current. It supports a wide range of system voltages (12V, 24V, 36V, 48V) and battery types (Lithium and Lead-acid), optimizing battery performance with a three-stage charging algorithm. The LCD display and keypad allow easy parameter configuration and system monitoring. With its built-in protection features and accurate fault code reporting system, it ensures stable and safe operation, providing reliable energy management for your solar system.

Video: PowMr Pstar Series Solar Charge Controller Overview

2. Important Safety Instructions

WARNING: CAREFULLY READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  • Carefully read the manual before the controller is installed and operated; retain the manual in a safe place for future reference.
  • The controller must not be installed or operated by the following persons, unless they are under strict instruction and supervision:
    • Anyone who lacks the appropriate knowledge, experience or competence, required for safe installation and/or usage.
    • Anyone with compromised/reduced physical, sensory or mental capabilities, which may affect safe installation and/or usage (including children).

Controller Installation and Operation

  1. There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair the controller.
  2. Install the controller in a location with good natural airflow/ventilation and sufficient unobstructed space around it; refer to the "3 Installation and Connection" section for more detail.
  3. Install the controller on a non-flammable substrate and ensure there are no heat-sensitive items in the immediate vicinity; it is normal for the controller to become hot during operation.
  4. Install the controller in a location where it is protected from environmental conditions such as direct sunlight, water, high moisture and dust, and also located well away from any flammable liquids or gasses. Controller is for indoor use only.
  5. Do not install or place/operate the controller on top of the battery, directly above the battery, or in a sealed compartment with the battery; batteries can emit explosive gasses.
  6. Do not cover or place any other items on top of the controller.

Battery Installation and Charging

  1. Install and charge the battery in a location with good natural airflow/ventilation.
  2. Ensure that there are no ignition sources near the battery; batteries can emit explosive gasses.
  3. Battery acid is corrosive; if battery acid comes into contact with skin immediately rinse with water.
  4. Do not charge non-rechargeable batteries. And Do Not charge Li-ion batteries if the battery temperature is below 0°C. Never charge a frozen battery.
  5. Ensure that the unit is properly set up for the type of battery intended to be charged.

Battery DC Connections

  1. Ensure that the DC system is fully shut down/isolated prior to disconnection of any existing cabling and/or new connections are made to the battery/DC system.
  2. Use flexible multi stranded copper cable with sufficient cross sectional area, inline with an appropriate fuse or circuit breaker; refer to the "3.4 Wiring Specification and Breaker Type" section for more detail.
  3. NEVER connect the solar panel array to the controller without a battery. Battery must be connected first.

Controller Setup

  1. Refer to the battery manufacturers instructions and specifications to ensure the battery is suitable for use with this controller and confirm the recommended charge settings.
  2. The integrated charge modes combined with adaptive charge logic are well suited for most common battery types; such as flooded lead-acid, Gel and LiFePO4.

3. Product Overview

The PowMr Pstar series solar charge controller features a clear LCD display and intuitive function keys for easy operation and monitoring. The unit is designed for wall mounting with a heatsink backplane for efficient cooling.

PowMr Pstar Solar Charge Controller Front and Back View with Labeled Parts

Image: Front and back view of the PowMr Pstar Solar Charge Controller with numbered components.

Component Identification

No.DescriptionNo.Description
1LCD display5Load port
2Function keys6USB port
3PV input port7Mounting hole (4 x Ø5mm)
4Battery port8Heat sink

4. Installation and Connection

4.1 Unpacking and Inspection

Before unpacking, check the package for damage. After unpacking, verify that the contents are complete and undamaged. The package should contain:

  • Controller
  • User manual

4.2 Preparing for Installation

The Pstar Controller range is designed for wall mounting using flanges on the heatsink backplane.

Select the Mount Location:

Before mounting, consider the following for a suitable and safe location:

  1. Install the controller in a location with good natural airflow/ventilation.
  2. Ensure sufficient unobstructed space around the controller. The minimum spacing between the top, bottom, and sides of the controller is 150mm.
Diagram showing recommended 150mm spacing around the solar charge controller for proper ventilation.

Image: Recommended 150mm spacing around the controller for optimal airflow.

  1. Install the controller on a non-flammable substrate, away from heat-sensitive items. The controller may become hot during operation.
  2. Install the controller in a location protected from direct sunlight, water, high moisture, and dust. It should also be well away from flammable liquids or gases. This controller is for indoor use only.
  3. Do not install or operate the controller on top of the battery, directly above the battery, or in a sealed compartment with the battery, as batteries can emit explosive gases.
  4. Do not cover or place any other items on top of the controller.
  5. Install the unit by screwing four M5 screws.

4.3 Things You Need

Ensure you have all necessary parts for installation and connection:

ItemQuantity
Pstar Controller (included)1
DC-cable to connect the positive DC connection (+) of the Pstar Controller to the positive polarity of DC input or DC output3
DC-cable to connect the negative DC connection (-) of the Pstar Controller to the negative polarity of DC input or DC output3
DC breaker3
Screw fitting (Ø5mm) to mount the controller to a surface. Use mounting materials suitable to carry the weight of the Pstar Controller.4
PV array. See section "4.4 PV Module Selection" for the configuration of solar panels1
Battery pack.1

4.4 Wiring Specification and Breaker Type

Determine the maximum PV input current based on the configured system voltage and by referring to the "6 Technical Specification" section. Note: The voltage in series shall not exceed maximum PV input open-circuit voltage.

ModelMax. DC output CurrentWire DiameterCircuit Breaker Spec
Pstar-30A20A10AWG2P-20A
Pstar-60A35A8AWG2P-35A
Pstar-80A50A6AWG2P-50A

The cables and circuit breakers of the battery should be selected based on the maximum charging current of the battery you connected.

4.5 PV Module Selection

When selecting proper PV modules, consider the following parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the controller.
Controller ModelPstar-30APstar-60APstar-80A
Max. PV array open circuit voltage of controller100Vdc100Vdc100Vdc
  1. Open circuit Voltage (Voc) of PV modules should be higher than Min. battery voltage.

4.6 Wiring Precautions

  1. Installation and connection work should be performed by a licensed electrician.
  2. To avoid short circuit and reverse polarity connection, ensure that the positive cable is connected to the positive polarity port (+) of the device, and the negative cable is connected to the negative polarity port (-) of the device.
  3. Too-thin cables and/or loose connections can cause dangerous overheating of the cables and/or terminals. Therefore, tighten all connections well to limit transition resistance. Use cables of the correct size. Refer to the "4.4 Wiring Specification and Breaker Type" section for details.
  4. Do not connect the inverter to the load side of the controller. Otherwise, irreversible damage may be caused to the device. If you need to install an inverter, see the following system application diagram of the controller.
Wiring diagram for the solar charge controller, showing connections for PV array, battery, load, and optional inverter.

Image: System application wiring diagram for the solar charge controller.

4.7 Installation and Connection Step-By-Step

  1. Mark the position of the mounting spots on the wall based on the mount holes of the controller. Then make 4 mounting holes in the wall with an electric drill according to the spots. Refer to the "4.2 Preparing for Installation" section for installation locations.
  2. Insert the expansion rubber screw plug into the mounting holes.
  3. Mount the controller vertically to the ground with terminals facing down; secure using the 4 mounting holes/slots on the base. To aid installation, it is recommended to 'hang' the unit using the 2 upper screws and then add the 2 lower screws, before fully securing all 4 screws. Recommend screws size is M5.
  4. Battery Connection: Connect the battery to the controller with the cables.
  5. PV Connection: Connect the PV array to the controller with the cables.
  6. DC Output Connection: Connect the load to the controller with the cables.
  7. Check before starting up: Refer to the wiring diagram. If everything is correct and all wires are firmly connected, close the circuit breakers at the battery side, PV module side, and load side in sequence to start up the controller.

NOTICE

  • All wiring must be performed by qualified personnel.
  • For safe operation and standard application, a circuit breaker of the corresponding specifications must be installed on the cable connecting to the controller. Confirm that the wire used is thick enough. Refer to "4.4 Wiring Specification and Breaker Type" section for selection of wiring and circuit breaker specifications.
  • Ensure that all circuit breakers are open until all cables are connected.
  • Connect the positive cable terminal to the positive port and the negative cable terminal to the negative port.
  • The above precautions also apply to the wiring of the PV side and the load side.

WARNING: Risk of electric shock!

  • Make sure that all power is turned off before connection, and then follow the corresponding inspections and operations.

5. Operation Mode

5.1 Charge Algorithm

The battery charging controller is equipped with an intelligent 3-stage charge characteristic for optimal battery charging. When switched on, the Pstar Controller always starts at the Bulk stage.

Graph illustrating the three-stage charging algorithm: Bulk Charge, Boost Charge, and Float Charge.

Image: Three-stage charging algorithm (Bulk, Boost, Float) showing battery voltage and current over time.

There are 3 integrated charge modes: Bulk, Boost, and Float. These three stages ensure fast, efficient, and safe battery charging, effectively extending battery life. The integrated charge modes, combined with adaptive charge logic, are well-suited for most common battery types, such as flooded lead-acid, Gel, and LiFePO4. The charging mode parameters can be set as required via the LCD screen. Refer to the "5.4 Browse and Configuration Parameter Step-By-Step" section for more information.

Charge Stages:

  • Bulk charge: The battery is charged at maximum current until the voltage reaches the configured boost charging voltage. The duration depends on the battery's discharge level, capacity, and charge current.
  • Boost charge: The battery is charged at the configured boost charging voltage, with the current slowly decreasing as the battery approaches full charge. The default boost stage duration is adaptive, intelligently varying based on the battery's discharge level. When the photovoltaic module is reconnected, a new charging cycle begins. If the battery is full, it directly enters the boost charging stage (Stage B), with a duration of 30 minutes.
  • Float charge: After the boost stage, the controller reduces the charging current to maintain the battery at the floating charging voltage, ensuring a full charge state. In this stage, loads can draw power from the solar panel. If loads exceed available power, the controller may not maintain the float voltage, and if the battery voltage drops below the Recharge Voltage, the system will return to the Bulk charging stage.

5.2 Alarm Function

The battery controller includes an integrated alarm function. For details on protection and fault alarms, refer to the "6 Protection" section.

5.3 Operation Interface Introduction

IconDescription
☀️Indicates the PV input state: daytime state/night state.
PV Input Voltage/Current/PowerIndicates the PV input voltage/ PV input current/ PV input power.
Battery CapacityIndicates the remaining battery capacity.
Battery Voltage/Temp/TypeIndicates the current battery voltage/ equipment temperature/ battery calibration voltage/ battery type/ boost charging voltage/ float charging voltage/ low DC cut-off recovery voltage/ low DC cut-off voltage.
DC Output Mode/DurationIndicates DC output mode and DC output operation duration.
Fault CodesIndicates the fault codes.

5.4 Browse and Configuration Parameter Step-By-Step

After connecting cables and starting the device, perform initial configuration based on your specific setup.

Function Keys:

KeyFunction
PV / ▲To switch PV input parameters information / Return to previous option.
BAT / ▼To switch charging information / Enter the next option.
SET / ⚙To adjust DC output mode and duration / Confirm and reserve settings.

NOTICE

  • The screen backlight automatically turns off after 20 seconds of inactivity to save power. Press any button to reactivate.
  • The display will automatically return to the default screen (PV input voltage & current, battery voltage & load enable duration) after 100 seconds of no button presses.

5.4.1 PV side - Checking PV input Information

Press "PV / ▲" key to switch PV information (PV input voltage, PV input current, and PV input power) in sequence.

5.4.2 Battery side - Checking Battery Information

Press "BAT / ▼" key to switch battery information (current battery voltage, equipment temperature, battery calibration voltage, battery type, boost charging voltage, float charging voltage, low DC cut-off recovery voltage, low DC cut-off voltage) in sequence.

Step 2. Calibrate battery voltage

The battery calibration voltage parameter corrects the current battery voltage measured by the controller. Operations:

  1. Once the parameter switches to the “battery calibration voltage” item, press and hold "BAT / ▼" key to enter the battery voltage calibration setting.
  2. Then press the "PV / ▲" or "BAT / ▼" keys to calibrate the battery voltage parameters of the controller according to the battery voltage measured by a multimeter. Finally press "SET / ⚙" to confirm.
Image showing a multimeter measuring battery voltage next to the solar charge controller for calibration.

Image: Battery voltage calibration using a multimeter.

Step 3. Select the Battery Type

Adjust battery type parameters based on the connected battery:

  1. Once the parameter switches to the battery type item, press and hold "BAT / ▼" key to enter the battery type adjustment setting.
  2. Then press "PV / ▲" or "BAT / ▼" to adjust the battery type. Finally press "SET / ⚙" to confirm. The operating voltage varies according to battery types.
  3. For details, refer to "5.5 Key Points of Battery Parameter Settings" section.
SequenceDisplayBattery Type
1SELSealed lead acid battery
2USEUser-defined
3N14Ternary lithium battery 14 strings
4N13Ternary lithium battery 13 strings
5N07Ternary lithium battery 7 strings
6N06Ternary lithium battery 6 strings
7N03Ternary lithium battery 3 strings
8L16Lithium iron phosphate battery 16 strings
9L15Lithium iron phosphate battery 15 strings
10L08Lithium iron phosphate battery 8 strings
11L04Lithium iron phosphate battery 4 strings
12FLdVented lead acid battery
13GELColloidal lead acid battery
Step 4. Customize configured voltage parameters
NOTICE
  • This step is required only when the battery type is set to "USE".

Once the battery type is set to "USE", the configurable parameters are presented in the following order. Increment of each click is 0.1V.

ItemSetting Range
Nominal system voltage12V/24V/36V/48V (optional)
Boost charging voltage9~17V
Float charging voltage9~17V
Low DC cut-off recovery voltage9~17V
Low DC cut-off voltage8.4~17V
CAUTION
  • The preceding parameter ranges apply to a 12V battery. For 24V/36V/48V systems, the range values are 2/3/4 times this range, respectively. The LCD only displays 12V battery voltage values.
WARNING
  • The above settings must follow the logic: Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage.

5.4.3 Load side - Configurate load enable duration

  1. Press and hold "SET / ⚙" key to enter the load mode setting.
  2. Then press "PV / ▲" or "BAT / ▼" to adjust load state or load enable duration.
  3. Finally press "SET / ⚙" to confirm.
Load Mode Options:
  • 00H: Solar light control mode (Loads supply power after dark and stop working after dawn).
  • 24H (Default): Turn on load immediately. A short press of the "DC / ▼" key immediately shuts off the load output.
  • 01H~23H: Adjust the load enable duration. Setting range is from 0 hour to 24 hours. Increment of each click is 1 hour.

5.5 Key Points of Battery Parameter Settings

5.5.1 The logic for setting battery voltage parameters

  1. Before customizing battery parameters, confirm the following parameters of the connected battery:
    • Max charging voltage
    • Discharging protection voltage
  2. After confirming the battery information, you can set the four key parameters according to the following logic: Max. charging voltage > Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage > Discharge protection voltage

5.5.2 Battery parameters of different types

For lead-acid battery & User define:
ParameterFLdGELSELUSE
Boost charging voltage14.6V14.2V14.4V14.4V
Float charging voltage13.8V13.8V13.8V13.8V
Low DC cut-off voltage11.0V11.0V11.0V11.0V
Low DC cut-off recovery voltage12.6V12.6V12.6V12.6V
For Ternary lithium battery:
ParameterN03N06N07N13N14
Boost charging voltage12.5V25.0V29.2V54.2V58.3V
Float charging voltage12.2V24.4V28.5V52.9V56.9V
Low DC cut-off voltage8.4V16.8V19.6V36.4V39.2V
Low DC cut-off recovery voltage9.0V18.0V21.0V39.0V42.0V
Lithium iron phosphate battery:
ParameterL04L08L15L16
Boost charging voltage14.5V29.0V54.4V58.0V
Float charging voltage13.8V27.6V51.8V55.2V
Low DC cut-off voltage11.2V22.4V42.0V44.8V
Low DC cut-off recovery voltage12.0V24.0V45.0V48.0V

6. Protection Features

6.1 Protection Provided

No.ProtectionDescription
1Battery Reverse PolarityFully protected against battery reverse polarity; no damage to the controller will result. Correct the miswire to resume normal operation.
2Maximum Charging Current limitEnsures safe charging current to prevent battery damage. Protects battery performance and prolongs battery life.
3Over Discharge ProtectionThe controller shuts down output for one minute.
4Short Circuit ProtectionThe controller shuts down output for one minute.
5Controller OverheatingWhen the equipment temperature exceeds 85°C, the control automatically stops charging. Charging resumes when the temperature is 75°C.

7. Troubleshooting

In case of a failure, the Pstar Controller display shows an error signal to help you find its source.

Fault codePossible CauseWhat to do
E65Battery undervoltageCharge the battery and wait until the battery voltage is higher than the low voltage cut-off voltage recovery point. Refer to "5.5.2 Battery parameters of different types" section for detail.
E63Battery overvoltageMeasure whether the battery voltage exceeds the rated voltage and turn off the photovoltaic array air switch.
E73Charging current is too highReduce the number of PV panels connected to the controller to reduce the PV input.
E60Controller over temperatureWhen the temperature of the device is cooled below the recovery temperature, normal charge and discharge control is resumed.
E81Controller overloadReduce the amount of load on controller connections.

8. Maintenance

The following inspections and maintenance tasks are recommended at least two times per year for best performance:

  • Make sure the controller is firmly installed in a clean and dry ambient.
  • Ensure no block on air-flow around the controller. Clear up any dirt and fragments on the heat sink.
  • Check all naked wires to ensure insulation is not damaged due to solarization, frictional wear, dryness, insects, or rodents. Repair or replace damaged wires if necessary.
  • Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
  • Confirm that all system components are grounded tightly and correctly.
  • Confirm that all terminals have no corrosion, insulation damage, high temperature, or burnt/discolored signs, and tighten terminal screws.
  • Check for dirt, nesting insects, and corrosion. If found, clear up in time.

WARNING: Risk of electric shock!

  • Make sure that all power is turned off before performing any maintenance operations, and then follow the corresponding inspections and operations.

9. Technical Specifications

FeaturePstar-30APstar-60APstar-80A
PV Input
Max Open Voltage of PV Module100V
PV Operation Voltage Range>System voltage and ≤100V
Max. Input Power:
For 12V system≤360W≤720W≤960W
For 24V system≤720W≤1440W≤1920W
For 36V system≤1080W≤2160W≤2880W
For 48V system≤1440W≤2880W≤3840W
Charge Mode
Charging technologyPWM
Charge Algorithm3-Stages
Self-consumption≤20mA
Nominal System Voltage12V/24V/36V/48V
Rated Charging Current30A60A80A
DC Output
Rated Output Current20A35A50A
USB Interface5V/2A*2
Environment
Operating Temperature Range-20°C ~ +55°C
Humidity Range≤90%, Non-condensing
General Specification
Protection ClassIP30
Dimension187*94*49mm187*132*60mm187*132*60mm
Net weight0.49kg0.77kg0.79kg

10. User Tips

  • Always ensure proper ventilation around the controller to prevent overheating, especially in warmer climates.
  • Double-check all wiring connections for polarity and tightness before powering on the system to avoid damage.
  • Regularly monitor the LCD display for any fault codes and address them promptly using the troubleshooting guide.
  • For optimal battery health, ensure the correct battery type is selected in the controller settings. If using a custom battery, carefully configure the voltage parameters.
  • Consider using appropriate fuses and circuit breakers as specified in the manual for all connections to protect your system.

11. Warranty and Support

The PowMr Pstar series solar charge controllers come with a 12-month warranty, as indicated on the product packaging.

For further assistance, technical support, or inquiries, please contact:

  • Company: SHENZHEN HEHEJIN INDUSTRIAL CO., LTD
  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Website: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

A detailed user manual in PDF format is also available for download: Download User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.