1. Important Safety Instructions
Please save these instructions.
This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information.
WARNING
Indicates a potentially dangerous condition. Use extreme caution when performing this task.
CAUTION
Indicates a critical procedure for safe and proper operation of the controller.
NOTE
Indicates a procedure or function that is important to the safe and proper operation of the controller.
1.1 General Safety Information
- Read all of the instructions and cautions in the manual before beginning the installation.
- There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair the controller.
- Do NOT allow water to enter the controller.
- Make sure all connections going into and from the controller are tight.
1.2 Charge Controller Safety
- NEVER connect the solar panel array to the controller without a battery. Battery must be connected first.
- Ensure input voltage does not exceed 190 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to make sure the voltage does not exceed this value when connecting panels together.
1.3 Battery Safety
- Use only sealed lead-acid, flooded, gel or lithium batteries which must be deep cycle.
- Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases.
- Be careful when working with large lead acid batteries. Wear eye protection and have fresh water available in case there is contact with the battery acid.
- Carefully read battery manuals before operation.
- Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Recycle battery when it is replaced.
WARNING
- Connect battery terminals to the charge controller BEFORE connecting the solar panel(s) to the charge controller. NEVER connect solar panels to charge controller until the battery is connected.
- Do NOT connect any inverters or battery charger into the load terminal of the charge controller.
- Once equalization is active in the battery charging, it will not exit this stage unless there is adequate charging current from the solar panel. There should be NO load on the batteries when in equalization charging stage.
2. Overview
The PowMr HHJ-60A is an advanced MPPT (Maximum Power Point Tracking) solar charge controller designed for efficient and reliable solar power systems. It features a powerful MPPT solution with a 60A charging current and an impressive 99.9% tracking efficiency. Its high-performance DSP controller ensures fast digital signal processing, making it a robust choice for various solar setups.
Video: Introduction to the PowMr HHJ-60A Solar Charge Controller, highlighting its key features and benefits.
2.1 Key Features
- High Efficiency: Up to 99.9% MPPT tracking efficiency and 98% peak conversion efficiency.
- Wide System Voltage: Automatically adapts to 12V, 24V, 36V, and 48V battery systems.
- High Charging Current: Provides a robust 60A charging current.
- Advanced Control: Equipped with a high-performance DSP controller for fast and accurate signal processing.
- Comprehensive Protection: Includes PV over current, PV short circuit, PV reverse polarity, battery over voltage, battery over discharge, load over current, load short circuit, and over temperature protection.
- Battery Compatibility: Compatible with various battery types including sealed lead-acid, flooded, gel, and lithium-ion (LiFePO4).
- 3-Stage Charging: Optimizes battery life with Equalize, Boost, and Float charging stages.
- Fault Diagnosis: Built-in system for easy troubleshooting.

Figure 2.1: Comparison of PowMr MPPT Controller vs. Others, highlighting 99% efficiency, 12V/24V/36V/48V battery support, and higher current/PV voltage limits (Max.PV 160VDC).
3. Setup and Installation
3.1 Dimensions
The controller has compact dimensions for easy integration into your solar system.
| Measurement | Value (mm) | Value (inches) |
|---|---|---|
| Length | 214 | 8.43 |
| Width | 115 | 4.53 |
| Height | 50 | 1.97 |
3.2 Wiring Diagram
Follow the diagram below for correct system connections. Ensure all connections are secure and observe polarity.

Figure 3.1: System connection diagram showing PV Solar Panels, MPPT Charge Controller, Battery, DC Load, AC Load, and Inverter. Includes Max.PV Input 160VDC and Max.PV Input Power for 12V (720W), 24V (1440W), 36V (2100W), and 48V (2800W) systems.
3.3 Connection Steps
Always connect components in the specified order to prevent damage.
- Install Air Circuit Breakers: Install air circuit breakers between the controller and batteries, and between the controller and PV modules. Ensure they are OFF before making connections.
- Connect Batteries (1st Step): Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol). If the system is 12V, ensure your battery voltage is above 12V for the controller to boot up.
- Connect Solar Panels (2nd Step): Ensure PV modules are protected from incident light. Verify that the solar panel voltage does not exceed the maximum permissible input current (Max.PV Input 160VDC). Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
- Connect Loads (3rd Step): Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol). To avoid any voltage on the wires, connect the wire to the load before connecting to the controller.
- Final Check & Tightening: Tighten all cables connected to the controller. Ensure there is a space of approximately 5.91 inches (15 cm) around the controller for proper ventilation.
- Power Up Sequence:
- Turn ON the air circuit breaker between the controller and batteries.
- Turn ON the air circuit breaker between the controller and PV modules.
- The controller will enter self-test mode. The LCD will display parameters if all connections are correct, and the RUN lamp (under the fan) will flash every second. If there is no response, re-check all connections and refer to the troubleshooting section.
3.4 Air Circuit Breaker and Wires Requirement
We strongly recommend connecting a fuse directly to the battery to protect against short circuits. Use insulated tools and ensure wire diameter is appropriate for expected currents.
| Model | Copper Wires | Air Circuit Breakers |
|---|---|---|
| HHJ-60A | 6mm²x2PCS | 100A |
4. Operating Instructions
4.1 LCD Display
The LCD provides real-time information about your solar system's status. It has a main interface and sub-interfaces for detailed settings and monitoring.

Figure 4.1: Detailed view of the controller's functional design, including the Backlight LCD Screen sub-interface (Load Timer, Floating Voltage, Absorption Voltage, Battery Type, Calibration Voltage, Low Voltage Disconnect) and Working Modes.
| Item | Description |
|---|---|
| PV voltage / Output power | Displays current PV input voltage and power output. |
| Battery voltage / Charging current | Shows current battery voltage and charging current. |
| Working mode / Temperature | Indicates the current operating mode and controller temperature. |
| Fault code | Displays error codes if any faults are detected. |
4.2 Working Modes
| Mode Code | Description |
|---|---|
| 3.0 | Night Mode, No Charging |
| 4.0 | MPPT Mode (Maximum Power Point Tracking) |
| 7.0 | Absorption Mode |
| 8.0 | Floating Mode |
4.3 3-Stage Charging
The controller employs a 3-stage charging algorithm to optimize battery performance and extend its lifespan.

Figure 4.2: Illustration of 3-stage charging (Equalize Charge, Boost Charge, Float Charge) for Sealed Lead Acid, Vented Gel, and Lithium Batteries.
- Equalize Charge: Periodically overcharges the battery to balance cell voltages and remove sulfate crystals. (Typically for flooded batteries).
- Boost Charge: Charges the battery at its maximum current until it reaches a set voltage, ensuring a rapid charge.
- Float Charge: Maintains the battery at a lower voltage to keep it fully charged without overcharging, compensating for self-discharge.
4.4 Manual Settings
Reminder: The controller will work fine under default settings except for lithium batteries. All manual setting steps must be carried out when the PV modules are disconnected from the controller.
- D00 (Load Working Time): Press PRG, LCD shows D00. Default is 24-hour. Press ENT until numbers flash, then UP/DOWN to set time. Long-press ENT to confirm. This output voltage is the same as the battery. For small DC loads less than 5A.
- D01 (Floating Charging Voltage): Press UP, LCD shows 13.8 (default for 12V battery). Press ENT until numbers flash, then UP/DOWN to set desired voltage. Long-press ENT to confirm. (Note: For multiple batteries in series, the controller automatically multiplies this value, but the LCD only displays the per-battery voltage).
- D02 (Absorption Charging Voltage): Continue pressing UP, LCD shows 14.5 (highest absorption charging voltage for 12V battery). Set as per D01.
- D03 (Battery Discharge Protection Voltage): Continue pressing UP, LCD shows 10.0 (protection value for 12V battery). Set as per D01. If battery voltage drops below this, output power from OU+ and OU- will cease.
- D04 (Battery Voltage Calibration): Continue pressing UP, LCD shows C12.2. Adjust this value to match the controller's detected battery voltage with the actual battery voltage.
- D05 (Battery Type Setting): Continue pressing UP, LCD shows battery type. Default is USE (User-defined). Select from the table below. When selecting SEL, GEL, or FLd, the controller automatically detects system voltage.
| Type Code | Battery Type |
|---|---|
| SEL | Sealed Lead-Acid Battery |
| GEL | Gel Sealed Lead-Acid Battery |
| FLd | Flooded Lead-Acid Battery |
| L04 | 4-series Lithium Iron Phosphate Battery |
| L08 | 8-series Lithium Iron Phosphate Battery |
| L15 | 15-series Lithium Iron Phosphate Battery |
| L16 | 16-series Lithium Iron Phosphate Battery |
| USE | User-defined Battery Type |
- D06 (System Voltage for USE Type): If D05 is set to USE, you must manually configure the system voltage (12V/24V/36V/48V) in D06.
Press ESC to exit the setting menu. After setting, disconnect and reconnect the battery to verify settings. Then connect PV modules.
5. Maintenance
The PowMr HHJ-60A MPPT Solar Charge Controller is designed for minimal maintenance. However, regular checks can ensure optimal performance and longevity.
- Visual Inspection: Periodically inspect the controller for any visible damage, loose connections, or signs of overheating.
- Cleanliness: Keep the controller clean and free from dust and debris. Ensure the cooling fan and vents are unobstructed for proper airflow.
- Connection Checks: Annually check all wiring connections (PV, battery, load) to ensure they are tight and free from corrosion.
- Environmental Conditions: Ensure the controller is installed in a well-ventilated area, away from direct sunlight, moisture, and flammable materials.
6. Troubleshooting
The controller has a built-in fault diagnosis system. Refer to the table below for common issues and their solutions.
6.1 Fault Codes and Solutions
| Code | Description | How to solve |
|---|---|---|
| 18 | Input PV voltage is low | Increase the PV voltage |
| 60 | Over-temperature protection | Fan will work and temperature reduction automatically |
| 63 | Battery voltage is high | Battery high voltage protection and wait for recovery |
| 65 | Battery voltage is low | Battery over-discharge and wait for recovery |
| 71 | Input PV voltage is high | Decrease the PV voltage |
| 73 | Over-charging current | Decrease the PV power |
6.2 Protection Features
- PV Over Current: The controller will limit charging power to its rated capacity. An oversized PV array will not operate at maximum power point.
- PV Short Circuit: If a PV short circuit occurs, the controller will stop charging. Remove the short to resume normal operation.
- PV Reverse Polarity: Full protection against PV reverse polarity. No damage to the controller. Correct the connection to start normal operation.
- Battery Over Voltage: If battery voltage exceeds 15.5V (for 12V system), the controller will stop charging to protect the battery from overcharging.
- Battery Over Discharge: When battery voltage drops to the low voltage disconnect point, the controller will stop discharging to protect the battery.
- Load Over Current Protection: If the load current exceeds 1.25 times the maximum load current rating, the controller will disconnect the load.
- Load Short Circuit Protection: If a load short circuit occurs, the protection will activate automatically.
- Over Temperature Protection: The controller will activate its fan and reduce temperature if it overheats.
7. Specifications
Detailed technical specifications for the PowMr HHJ-60A MPPT Solar Charge Controller.
| Parameter | Value |
|---|---|
| Charging Mode | 3-stage |
| Max. PV Input Power | |
| 12V System | 720W |
| 24V System | 1440W |
| 36V System | 2100W |
| 48V System | 2800W |
| Input Specification DC | |
| 12V System | 20V~80V |
| 24V System | 37V~105V |
| 36V System | 50V~160V |
| 48V System | 72V~160V |
| Battery Voltage Automatic Recognition | |
| 12V System | DC9V~DC15V |
| 24V System | DC18V~DC29V |
| 36V System | DC30V~DC39V |
| 48V System | DC40V~DC60V |
| Overcharging Protection Voltage | 60V |
| Limited Current Protection | 61A |
| Max Efficiency | ≥98.1% |
| PV Utilization | ≥99% |
| Protection Function | |
| Temperature Protection | 75°C / 167°F |
| Fan-on Temperature | >45°C / 104°F |
| Fan-off Temperature | <40°C / 95°F |
| Properties | |
| Size (mm)/(in) | 214x115x50mm / 8.43x4.53x1.97in |
| Net Weight (Kg)/(lb) | 1.1 / 2.43 |
| Gross Weight (Kg)/(lb) | 1.2 / 2.65 |
| Electromagnetic Compatibility | EN61000, EN55022, EN55024 |
| Enclosure | IP21 |
| Environmental Temperature | -20°C ~ +55°C |
| Storage Temperature | -40°C ~ +75°C |
8. User Tips
- Ventilation is Key: Always ensure adequate airflow around the controller. Overheating can reduce efficiency and lifespan.
- Check Connections Regularly: Periodically inspect all wiring for tightness and corrosion, especially in systems exposed to varying weather conditions.
- Monitor Battery Health: Pay attention to your battery's performance. Proper charging settings (especially for lithium batteries) are crucial for battery longevity.
- Understand Your System: Familiarize yourself with the LCD display and fault codes to quickly diagnose and resolve minor issues.
9. Warranty and Support
9.1 Warranty Regulations
PowMr provides the following warranty for the HHJ-60A MPPT Solar Charge Controller:
- 30-Day Replacement: Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal usage conditions (with authorization from technical personnel).
- 2-Year Repair: Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.
Note: Disassembling the product privately will void the warranty.