ATORCH HDC-085C

Contents

ATORCH HDC-085C Type-C Power Meter User Manual

Model: HDC-085C

1. Introduction

The ATORCH HDC-085C is a multi-function digital display Type-C power meter designed to measure DC voltage, current, power, energy, and capacity. It supports the PD3.1 protocol and is ideal for testing cell phone charging performance and other USB-C powered devices. This manual provides detailed instructions for safe and effective use of your device.

ATORCH HDC-085C Type-C Power Meter

Figure 1: ATORCH HDC-085C Type-C Power Meter

2. Product Overview

2.1 Key Features

  • Wide Voltage Range: DC 4.5V to 50V
  • High Current Measurement: 0-6A (instant peak 12A)
  • High Power Measurement: Up to 600W
  • Supports PD3.1 Protocol
  • Multi-function Digital Display: Shows Voltage, Current, Power, Energy (Wh), Capacity (mAh), Timing, CPU Temperature, and Max/Min values.
  • 360° Four-way Rotation High-Definition Display Screen
  • Brightness Adjustment and Display Off Function
HDC-085C supporting 50V 12A 600W and PD3.1 protocol

Figure 2: High voltage, current, and power capabilities with PD3.1 support

HDC-085C showing multiple functional applications like voltage, current, power, energy, capacity, timing, and temperature

Figure 3: Multiple functional applications displayed

2.2 Interface Function Diagram

Diagram showing C Male input/output, C Female input/output, Data display area, Rotate screen buttons, and Function buttons

Figure 4: Interface Function Diagram

  • C Male input/output: Connects to the power source (charger).
  • C Female input/output: Connects to the load (device being charged).
  • Data display area: Shows all measurement parameters.
  • Rotate screen buttons: Used to rotate the display.
  • Function buttons: Click to switch interfaces; long press on different interfaces for data reset, empty load reset, brightness adjustment, etc.

3. Setup and Connection

Important Notice: When using a USB-C port charger, this meter will only light up and display when both the charger and the phone (or load) are connected at the same time!

3.1 Connection Methods

Diagram showing two operation methods for connecting the HDC-085C. Method 1: Mobile phone -> HDC-085C -> Charger. Method 2: Charger -> HDC-085C -> Mobile phone.

Figure 5: Connection Methods

  1. Operation Method 1: Connect the HDC-085C's C Male input/output to your mobile phone (or load). Then, connect the HDC-085C's C Female input/output to your charger.
  2. Operation Method 2: Connect the HDC-085C's C Male input/output to your charger. Then, connect the HDC-085C's C Female input/output to your mobile phone (or load).

4. Operating Instructions

4.1 Functional Operation

  • Function Key: Click to cycle through the different display interfaces. Press and hold for several functions in different screens, including data reset, empty load reset, and brightness adjustment. (Tip: Long press can also adjust brightness when in the large font interface on the second page).
  • Spin Key: Click to rotate the display in four directions (360° rotation).
HDC-085C showing 360 degree four-way rotation of the display screen

Figure 6: 360° Four-way Display Rotation

4.2 Display Interfaces

Click the function button to cycle through the following 5 interfaces:

Images of the five display interfaces: Main test interface, Large font display, Current Reset Zero, Display font switching colors, and Off Screen design.

Figure 7: Available Display Interfaces

  1. Main Test Interface: Displays Voltage (V), Current (A), Power (W), PVmAh, mWh, CPU temperature, and Max-V, Max-A, Max-W values.
  2. Large Font Display: Shows Voltage (V), Current (A), and Power (W) in a larger font for easier readability.
  3. Current Reset Zero: Displays '00.00A Zero No-load Current'. Use this to reset current readings.
  4. Display Font Switching Colors: Allows you to switch between different display color styles (e.g., white font or color font). Note: Brightness cannot be set in this mode.
  5. Off Screen Design: Turns the display off while the meter continues to function.
HDC-085C displaying white font on its screen

Figure 8: Example of White Font Display

4.3 Product Demonstration Video

Video 1: HDC-085C Product Overview and Operation

5. Specifications

Parameter Value
Product Name Type-C Tester
Model HDC-085C
Working Voltage DC 4.5~50V
Working Current 0~6A (short-term peak 12A)
Self Power Consumption <0.15W
Power Display 0~600W
Sampling Resistor 0.001R
Data Retention Period $T_{A}=55^{\circ}C$ 20 years
Energy Display 0~9999WH
Capacity Display 0~99999mAh
Working Temperature 0~45°C / 32~113°F
Product Size 43mm*25mm*10mm

6. User Tips

  • The device is very handy for measuring charging parameters, especially capacity.
  • Data acquired remains stored in its memory after a power cut, which is useful for long-term monitoring.
  • The display switches from white to color, offering visual preference.
  • It's a compact and sturdy device, making it convenient for everyday use and travel.
  • Remember that the device requires both a charger and a load (e.g., phone) to be connected to power on and display readings.

7. Troubleshooting

Frequently Asked Questions

  1. Question 1: Why does the product not display when plugged into the charger separately?

    Answer: The Type-C port of most chargers defaults to no voltage output. At this time, the product has no power supply and no display. The charger will only have voltage output when the load protocol is detected, and the product will only display it at this time.

  2. Question 2: Why can't the test meter measure 10A or 120W on my product charger?

    Answer: The values tested by this product are real-time charging parameters during the charging process. The parameters marked on the charger are the maximum power parameters of the product, and not always output such large parameters.

  3. Question 3: Why occasionally displays a current of 0.01-0.02A when the output is not connected to a load?

    Answer: This product uses bidirectional current detection, and a small no-load current is a normal phenomenon. However, it can also be reset by quickly touching the current reset interface three times.

  4. Question 4: Why is the measured capacity value in this table significantly different from the nominal battery capacity value of the mobile phone?

    Answer: The measured capacity value in this table is the current voltage capacity value. If you need to know the capacity value of the phone's battery at 3.7V voltage, please use this table to display the power value and convert it according to the formula.

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Handling: Avoid dropping the device or subjecting it to strong impacts, as this may damage internal components or the USB-C port.

9. Warranty and Support

For any issues or support inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims.

© 2023 ATORCH. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.