1. About This Manual

1.1 Purpose

This manual describes the assembly, installation, operation, and troubleshooting of your PowMr Hybrid Solar Inverter Charger. Please read this manual carefully before installation and operation. Keep this manual for future reference.

1.2 Scope

This manual provides safety and installation guidelines, as well as information on tools and wiring required for the inverter.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

3. Product Overview

The PowMr Hybrid Solar Inverter Charger is a multi-function device combining inverter, solar charger, and battery charger functions to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings like battery charging current, AC/solar charger priority, and acceptable input voltage.

3.1 Features

  • Pure sine wave inverter output.
  • Configurable input voltage range for home appliances and personal computers via LCD setting.
  • Configurable battery charging current based on applications via LCD setting.
  • Configurable AC/Solar Charger priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Auto restart while AC is recovering.
  • Overload/Over temperature/Short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • WIFI/GPRS (Optional) for remote monitoring.
  • Can connect to lithium batteries.

3.2 Basic System Architecture

The inverter integrates with PV modules, a battery system, and can draw power from a generator or utility grid to supply power to home appliances.

PowMr Hybrid Solar Inverter Charger Front View
Figure 1: PowMr Hybrid Solar Inverter Charger (Two Models)
Inverter LCD Display showing real-time data
Figure 2: Real-Time Display of Information Data on LCD
Inverter Input and Output Modes Diagram
Figure 3: Four Safe Charging Modes (Solar, Utility, Solar Priority, Solar+Utility) and Three Output Modes (PV Priority, Utility Priority, Inverter Priority)

3.3 Product Overview - Components

The inverter features an LCD display, status indicators, function buttons, and various input/output ports.

  • LCD Display: Shows operational status and settings.
  • Status Indicator: LED for operational status.
  • Charging Indicator: LED for charging status.
  • Fault Indicator: LED for fault conditions.
  • Function Buttons: ESC, UP, DOWN, ENTER for navigation and setting adjustments.
  • Power On/Off Switch: Main power control.
  • AC Input: Terminal for grid or generator connection.
  • AC Output: Terminal for connecting loads.
  • PV Input: Terminal for solar panel connection.
  • Battery Input: Terminal for battery bank connection.
  • RS-232 Communication Port: For data communication and monitoring.

Video 1: Unboxing and Product Overview. This video demonstrates the contents of the package, highlights key features such as the 3000W max output power, 230V rated output voltage, 80A max charging current, compatibility with Lithium-ion and Lead-acid batteries, 24V system voltage, 30-400V MPPT voltage range, and 3000W max PV input power.

4. Setup (Installation)

4.1 Unpacking and Inspection

Before installation, inspect the unit for any damage. The package should contain:

  • The inverter unit x 1
  • User manual x 1

4.2 Preparation

Before connecting any wiring, remove the bottom cover by unscrewing two screws.

4.3 Mounting the Unit

Consider the following points for installation:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install at eye level for easy LCD display reading.
  • Allow approximately 20 cm clearance on sides and 50 cm above/below for proper air circulation.
  • Ambient temperature should be between $0^{\circ}C$ and $55^{\circ}C$.
  • Mount vertically on the wall.
  • Ensure sufficient space for heat dissipation and wiring.

NOTE: Suitable for mounting on concrete or other non-combustible surfaces only. Use M4 or M5 screws for mounting.

4.4 Battery Connection

CAUTION: Install a separate DC over-current protector or disconnect device between the battery and inverter. All wiring must be performed by qualified personnel. Use appropriate cable sizes for safety and efficient operation.

Recommended Battery Cable Sizes:

ModelWire SizeCable (mm²)Torque Value (max)
2.0KVA 12V1 x 4AWG222 Nm
3.2KVA 24V1 x 6AWG142 Nm

Connection Steps:

  1. Remove 18 mm insulation sleeve from positive and negative conductors.
  2. Use bootlace ferrules with a proper crimping tool.
  3. Connect all battery packs as per the provided diagram (series for 24V, parallel for increased capacity).
  4. Insert battery wires into inverter connectors, ensuring bolts are tightened to 2 Nm. Verify correct polarity (+ to + and - to -) at both battery and inverter.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

4.5 AC Input/Output Connection

CAUTION: Install a separate AC breaker between the inverter and AC input power source. Do NOT mis-connect input and output connectors. All wiring must be performed by qualified personnel. Use appropriate cable sizes.

Suggested AC Cable Requirements:

ModelGaugeTorque Value
2.0KVA 12V14 AWG0.5~0.6Nm
3.2KVA 24V12 AWG1.2 Nm

Connection Steps:

  1. Open DC protector or disconnector before AC connection.
  2. Remove 10mm insulation sleeve for conductors. Shorten phase L and neutral N by 3mm.
  3. Insert AC input wires according to polarities (L, N, Ground) and tighten terminals.
  4. Insert AC output wires according to polarities (L, N) and tighten terminals.

4.6 PV Connection

CAUTION: Install a separate DC circuit breaker between the inverter and PV modules. All wiring must be performed by qualified personnel. Use appropriate cable sizes.

Suggested PV Cable Requirements:

ModelWire SizeTorque Value (max)
2.0KVA 12V / 3.2KVA 24V1x16AWG1.2 Nm

PV Module Selection Parameters:

  • Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter (400Vdc).
  • Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
  • PV Array MPPT Voltage Range: 30Vdc-400Vdc.

Connection Steps:

  1. Remove 10 mm insulation sleeve from positive and negative conductors.
  2. Use bootlace ferrules with a proper crimping tool.
  3. Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive to positive and negative to negative.

4.7 Final Assembly

After connecting all wirings, replace the bottom cover by screwing four screws.

5. Operating

5.1 Power ON/OFF

Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the side of the case) to turn on the unit.

5.2 Operation and Display Panel

The front panel includes three indicators (Status, Charging, Fault), four function keys (ESC, UP, DOWN, ENTER), and an LCD display showing operating status and power information.

5.3 LCD Display Icons

The LCD display provides detailed information on input source, configuration, fault codes, output information, and battery status. Icons represent AC input, PV input, input voltage/frequency/power, warning/fault codes, output voltage/frequency/load, battery level, and operational modes (utility, PV, bypass, charging, inverter).

5.4 LCD Setting

Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs and ENTER to confirm. ESC exits the setting mode. Key settings include:

  • Output Source Priority (Program 01): Configure how loads are powered (Utility first, Solar first, SBU priority).
  • Maximum Charging Current (Program 02): Set total charging current from solar and utility.
  • AC Input Voltage Range (Program 03): Select range for appliances or UPS.
  • Battery Type (Program 05): Select AGM, Flooded, or User-Defined.
  • Auto Restart (Programs 06, 07): Enable/disable auto restart after overload or over-temperature.
  • Output Frequency (Program 09): Set to 50Hz or 60Hz.
  • Output Voltage (Program 10): Set to 220V, 230V, or 240V.
  • Battery Equalization (Program 30-36): Enable, set voltage, time, timeout, and interval for battery equalization.

5.5 Display Setting

Press UP or DOWN to cycle through various display screens showing input voltage, output voltage, input frequency, PV voltage, charging current, charging power, battery voltage, load percentage, load in Watt/VA, and DC discharging current.

5.6 Operating Mode Description

The inverter operates in several modes:

  • Standby Mode: Inverter is off, but can charge batteries.
  • Power Saving Mode: Output turns off when load is low.
  • Line Mode: Unit provides power from mains and charges battery.
  • Battery Mode: Unit provides power from battery and PV.
  • Fault Mode: Indicates internal or external errors.

5.7 Battery Equalization Description

Equalization reverses negative chemical effects like stratification and removes sulfate crystals, improving battery capacity and lifespan. It is recommended to equalize batteries periodically.

How to Apply Equalization Function:

  1. Enable battery equalization in LCD setting program 30.
  2. Set equalization interval in program 35.
  3. Activate equalization immediately in program 36.

6. Maintenance

6.1 Clearance and Maintenance for Anti-Dust Kit (Optional)

The inverter comes with a pre-installed anti-dust kit. This kit helps keep dust out and activates an internal thermal sensor to adjust temperature, enhancing product reliability.

Maintenance Steps:

  1. Remove screws securing the dustproof case.
  2. Remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case.
  4. Re-assemble the dust-kit back to the inverter.

NOTICE: The anti-dust kit should be cleaned every one month.

7. Troubleshooting

Refer to the table below for common issues and their solutions.

ProblemExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup.Battery voltage too low (<1.91V/Cell).1. Re-charge battery. 2. Replace battery.
No response after power on.1. Battery voltage far too low (<1.4V/Cell). 2. Internal fuse tripped.1. Contact repair center for fuse replacement. 2. Re-charge battery. 3. Replace battery.
Mains exist but unit works in battery mode.Insufficient quality of AC power.1. Check AC wires. 2. Check generator/input voltage range.
When unit turns on, internal relay switches on/off repeatedly.Battery is disconnected.Check if battery wires are connected well.
Fault code 07 (Overload).Inverter is overloaded 110% and time is up.Reduce connected load.
Fault code 05 (Output short circuited).Output short circuited.Check wiring and remove abnormal load.
Fault code 02 (Over temperature).Internal converter temperature over $120^{\circ}C$.Check air flow or ambient temperature.
Buzzer beeps continuously and red LED is on.Battery is over-charged / Battery voltage is too high.Check battery specifications.
Fault code 01 (Fan fault).Fan fault.Replace the fan.
Fault code 08/09/53/57 (Internal components).Internal components failed.Return to repair center.
Fault code 51 (Over current).Over current or surge.Restart unit; if error persists, return to repair center.

8. Specifications

8.1 Line Mode Specifications

Feature2.0KVA-12V3.2KVA-24V
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage (UPS)170Vac±7V
Low Loss Voltage (Appliances)90Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto sensing)
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time (UPS)10ms typical
Transfer Time (Appliances)20ms typical

8.2 Inverter Mode Specifications

Feature2.0KVA-12V3.2KVA-24V
Rated Output Power2000VA/1600W3200VA/3000W
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac ±5%
Output Frequency50Hz
Peak Efficiency94%
Nominal DC Input Voltage12Vdc24Vdc
Cold Start Voltage11.5Vdc23.0Vdc
No Load Power Consumption<25W<35W

8.3 Charge Mode Specifications

Feature2.0KVA-12V3.2KVA-24V
Charging Algorithm3-Step
AC Charging Current (Max)60Amp
Bulk Charging Voltage (Flooded)14.6Vdc29.2Vdc
Bulk Charging Voltage (AGM/Gel)14.1Vdc28.2Vdc
Floating Charging Voltage13.5Vdc27Vdc
PV Array MPPT Voltage Range30~400Vdc
Max. PV Array Open Circuit Voltage400Vdc
Max Charging Current (AC + Solar)80Amp

8.4 General Specifications

Feature2.0KVA-12V3.2KVA-24V
Safety CertificationCE
Operating Temperature Range-10°C to 50°C
Storage Temperature-15°C ~ 60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm357X273X95
Net Weight, kg4.64.8

9. User Tips

  • WiFi Connectivity: Some models offer WiFi connectivity for remote monitoring. Check your specific model's features or product packaging for WiFi module inclusion.
  • Two-Phase Input: This inverter is designed for single-phase input (phase and neutral). It does not support two-phase input directly.

10. Warranty & Support

For technical support, warranty claims, or service, please contact PowMr customer service.

  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.