1. Introduction
This manual provides detailed instructions for the Aideepen 5A 35W Adjustable Electronic Load Tester. This device is designed for testing batteries, power supplies, and other electrical components by providing a controllable discharge load. It features stable performance, a wide application range, and comprehensive protection mechanisms.
2. Product Features
- High-quality materials for guaranteed quality and stable performance.
- Compact size and exquisite appearance.
- Easy to use with a clear LCD screen.
- Wide application range for various testing scenarios.
- Adjustable discharge current via a potentiometer.
- Intelligent temperature-controlled fan and aluminum heat sink for efficient cooling.
- Automatic statistics for discharge capacity and time with power-off storage.
- Comprehensive software and hardware protection mechanisms.
- Anti-reverse connection protection for both power supply and load input ports.
3. Specifications
| Parameter | Value |
|---|---|
| Load Power Supply Voltage | DC5.0V (with anti-reverse connection) |
| Load Power Supply Current | <=200mA |
| Load Input Voltage | DC1.5V-25V (with anti-reverse connection) |
| Load Input Current | 0.00A-5.00A |
| Voltage Accuracy | ± (1%+1 word), calibratable |
| Current Accuracy | ± (1%+1 word), calibratable |
| Cooling Method | Intelligent temperature-controlled fan + aluminum heat sink |
| Fan Speed | 8000rpm |
| Working Environment Temperature | -15°C to 50°C |
| Undervoltage Protection (LVP) Threshold | Default 1.5V (adjustable 1.5V-24.5V) |
| Overvoltage Protection (OVP) Threshold | Default 25.0V (adjustable 1.5V-25.0V) |
| Overcurrent Protection (OCP) Threshold | Default 4.10A/5.10A (adjustable) |
| Overpower Protection (OPP) Threshold | Default 25.5W/35.5W (adjustable) |
| Overtemperature Protection (OTP) | Activates when load temperature exceeds 80°C |
4. Setup
Before operation, ensure all connections are secure and correct. The module features anti-reverse connection protection for safety.
- Power On: Connect the micro USB cable to the tester's power input. The LCD screen will light up, displaying the initial voltage and current.
- Connect Load: Connect the battery or power source you wish to test to the input terminals (IN+ and IN-). Ensure correct polarity.
- Initial Check: Verify the input voltage displayed on the LCD.


5. Operating Instructions
The tester features an LCD screen for displaying various parameters and several buttons for control and settings.

5.1 Basic Operation
- Adjust Discharge Current: Use the potentiometer (labeled 'I-ADJ') to adjust the desired discharge current.
- Open/Close Load: Short press the ON/SET button to open or close the load. When the load is active, the RUN indicator light remains on.
- Switch Display Interface: Short press the SELECT button to switch between different display interfaces (e.g., voltage, current, power, capacity, discharge time). Long press SELECT to switch to the upper display interface (e.g., temperature).
5.2 Resetting Statistics
To reset the discharge capacity or discharge time statistics, long press the SELECT button when the respective value is displayed on the LCD screen. It is recommended to reset statistics to zero before starting a new test.
5.3 Setting Parameters
- Enter Setting Mode: Long press the ON/SET button to enter the setting interface.
- Switch Parameters: Short press the SELECT button to cycle through various setting parameters (e.g., LVP, OVP, OCP, OPP, OAH, OHP, OTP).
- Adjust Parameter Value: Use the + and - buttons to increase or decrease the value of the selected parameter.
- Exit Setting Mode: Long press the ON/SET button again to exit the setting interface and save changes.
5.4 Operation Video
For a visual guide on connecting the battery, adjusting discharge current, switching display interfaces, and setting parameters, please refer to the official operation video:
Video 1: ZK-FX25/35 Operation Video. Demonstrates power-on, battery connection, current adjustment, display switching, and setting protection parameters.
6. Protection Mechanisms
The electronic load tester incorporates comprehensive software and hardware protection features to ensure safe operation.
6.1 Hardware Protection
- Anti-Reverse Connection Protection: Both the module power supply port (USB) and the load input port (IN+/IN-) are protected against reverse polarity connections.
6.2 Software Protection (Adjustable Thresholds)
- Undervoltage Protection (LVP): Default 1.5V. If the input voltage drops below this threshold, the load will automatically shut off. Adjustable between 1.5V and 24.5V.
- Overvoltage Protection (OVP): Default 25.0V. If the input voltage exceeds this threshold, the RUN indicator light flashes and the LCD displays "OVP". Adjustable between 1.5V and 25.0V.
- Overcurrent Protection (OCP): Default 4.10A/5.10A. If the input current exceeds this threshold, the RUN indicator light flashes and the LCD displays "OCP". Adjustable by the user.
- Overpower Protection (OPP): Default 25.5W/35.5W. If the discharge power exceeds this threshold, the RUN indicator light flashes and the LCD displays "OPP". Adjustable by the user.
- Overtemperature Protection (OTP): Activates when the load temperature exceeds 80°C. The fan will automatically start when the load discharge power is greater than 10W or the load temperature is greater than 40°C.
- Over-Capacity Protection (OAH): Can be set to ON/OFF. When ON, a maximum discharge capacity threshold can be set. If the accumulated discharge capacity exceeds this threshold, the load will automatically shut off.
- Over-Time Protection (OHP): Can be set to ON/OFF. When ON, a maximum discharge time threshold can be set. If the accumulated discharge time exceeds this threshold, the load will automatically shut off.
When any software protection is triggered, the buzzer emits a beep alarm sound and the RUN indicator light flashes. The output is turned off.
7. Maintenance
- Keep the device clean and free from dust and moisture.
- Avoid exposing the device to extreme temperatures or direct sunlight.
- Do not attempt to disassemble or repair the device yourself, as this may void the warranty and cause damage.
- Store in a cool, dry place when not in use.
8. Troubleshooting
- Device not powering on: Ensure the micro USB power supply is connected correctly and providing 5V. Check the cable for damage.
- No discharge: Verify the load is connected correctly to IN+ and IN-. Ensure the load is turned on by short pressing the ON/SET button. Check if any protection (LVP, OVP, OCP, OPP) is active.
- Buzzer beeping and RUN light flashing: This indicates a protection mechanism has been triggered. Check the LCD for the protection code (OVP, OCP, OPP) and address the issue (e.g., reduce current, check voltage).
- Fan not spinning: The fan automatically starts when the discharge power exceeds 10W or the load temperature exceeds 40°C. If these conditions are met and the fan is still not spinning, contact support.
- Statistics not resetting: Ensure you are long-pressing the SELECT button when the discharge capacity or time is displayed.
9. User Tips
- Always reset discharge statistics before starting a new test to ensure accurate measurements.
- Familiarize yourself with the protection settings (LVP, OVP, OCP, OPP, OAH, OHP) to prevent damage to the device or the tested component.
- For precise current adjustment, make small turns on the potentiometer.
10. Warranty and Support
For any technical assistance, warranty claims, or further inquiries, please contact the seller or manufacturer directly. Keep your purchase records for reference.
User manual (PDF) is available for download: View PDF Manual