1. Introduction

The Aideepen DTS6619-WIFIPV 100A is a smart 3-phase, four-wire overvoltage and undervoltage current limiting protector designed for home and industrial applications. Developed by the Electric Condition Institute, this device offers advanced protection features and remote control capabilities via a mobile application. It is built with high-quality, flame-retardant materials and a smart chip, ensuring durability and reliable performance. The device automatically recloses the power supply once a fault is cleared, minimizing downtime and enhancing safety.

Aideepen Smart 3-Phase Circuit Breaker with mobile app control
The Aideepen Smart 3-Phase Circuit Breaker, showing its digital display and connectivity with a mobile application for remote control.

2. Key Features

  • High-Quality Construction: Made from flame-retardant materials with a built-in smart chip, offering wear-resistance, anti-interference, high strength, and durability.
  • Digital LCD Display: Features an LCD screen that simultaneously displays 3 real-time data points (voltage, current, power) for accurate and readable information.
  • Easy Installation: Compact size suitable for distribution box or wall mounting, with guide rail type snap mounting that requires no screws.
  • Automatic Reclosing Protection: Automatically cuts off power during over-voltage or over-current events and recloses once the fault is cleared.
  • Multiple Protections: Includes over-voltage, under-voltage, current limit, phase break, zero drift, phase sequence, voltage imbalance, and current imbalance protections.
  • Mobile APP Control: Remote threshold setting and switching via a mobile app (Tuya app) for convenience.
  • Convenient Wiring: Extra-large wiring port design facilitates quicker and easier wiring.
  • Physical Button Design: Allows customization of threshold values with sensitive operation.

3. Specifications

ParameterValue
Product NameAutomatic Reclosing Protector
Model NumberDTS6619-WIFIPV 100A
MaterialPlastic
DisplayLCD Display
Rated Voltage80-380V
Rated Current100A
Rated Frequency50Hz
ConnectionWiFi + Tuya APP
Operating Temperature-20℃ to 60℃
TypeConventional Circuit Breaker, Smart Circuit Breaker
Is Smart DeviceYes
CertificationCE
Dimensions (W x H x D)75.3mm x 89.5mm x 58.3mm

4. Package Contents

  • Circuit Breaker x 1

5. Safety Warnings and Precautions

  • This product does not have an isolation function. Always disconnect the front stage power supply when repairing the circuit breaker switch.
  • The zero line (N line) of this product is directly connected without a disconnection function.
  • The protector must be wired strictly according to the markings on the device. Incorrect wiring can lead to malfunction or damage.
  • While this product has a limited current protection function, it cannot replace dedicated circuit breakers. For short circuit protection, it is recommended to install circuit breakers such as DZ47 and C65 at the front end of the line.
  • Before use, ensure all clamp screws are tightened to prevent poor contact and potential product damage.

6. Installation

6.1. Installation and Usage Conditions

  • Temperature: -20°C to 60°C
  • Humidity: ≤85%
  • Altitude: Not exceeding 2000m
  • Pollution Level: Level 3
  • Design: Modular design for exterior and guide rail installation.
  • Wiring Capacity: Insulated copper wire of 35 square millimeters and below.

6.2. Wiring and Dimensions

The device is designed for easy installation on a DIN rail. Refer to the diagrams below for wiring connections and physical dimensions.

Side view of the circuit breaker showing input and output terminals for L1, L2, L3, and N lines.
Side view of the circuit breaker with clearly labeled input (IN) and output (OUT) terminals for L1, L2, L3, and N lines.
Diagram showing the dimensions of the circuit breaker: 75mm width, 89.5mm height, and 35mm depth for the main body, with a total depth of 45mm including the display.
Physical dimensions of the circuit breaker (Width: 75mm/2.95in, Height: 89.5mm/3.52in, Depth: 45mm/1.77in, Mounting Depth: 35mm/1.38in).

7. Initial Setup and WiFi Configuration

7.1. App Installation

Download the Tuya Smart app from your mobile device's app store (Google Play Store for Android or Apple App Store for iOS).

7.2. WiFi Connection

  1. Ensure the circuit breaker is powered on.
  2. On the circuit breaker's display, navigate to the "Voltage" interface.
  3. Long press and hold the setting button (gear icon) to enter the WiFi configuration mode. The WiFi indicator will flash.
  4. Open the Tuya Smart app on your smartphone.
  5. Follow the in-app instructions to add a new device. Select the appropriate device type (e.g., "Circuit Breaker" or "Energy Meter").
  6. Confirm the device's WiFi indicator is flashing as instructed by the app.
  7. Enter your WiFi network credentials (SSID and password).
  8. The app will attempt to connect to the device. Once connected, the WiFi indicator on the circuit breaker will show a steady light.

7.3. WiFi Indicator Status

  • 1 flash: Waiting for WiFi signal to be detected.
  • 2 slow flashes: WiFi offline status.
  • 3 long lights: WiFi is connected.
Mobile phone displaying the Tuya app interface for controlling the smart circuit breaker.
Mobilephone APP Control: After downloading the app, you can set thresholds or switch remotely.

8. Operation

8.1. Digital LCD Display

The circuit breaker features a digital LCD display that shows real-time electrical parameters for each phase (L1, L2, L3).

Close-up of the circuit breaker's LCD display showing voltage readings for L1, L2, and L3.
Digital LCD Display: Shows 3 real-time data points simultaneously.

8.2. Physical Button Control

The device includes physical buttons for navigation and setting adjustments. Threshold values can be customized as needed.

Close-up of the circuit breaker's physical buttons for settings and navigation.
Physical button design allows for sensitive operation and customization of threshold values.

8.3. Displaying Parameters

Press the up and down buttons on the device to switch and display the voltage, current, power, power factor, and frequency of the three phases.

8.4. Multi-Protections

The device offers comprehensive protection against various electrical anomalies.

Image highlighting the multi-protection features of the circuit breaker.
Multi-protections: Includes overvoltage, undervoltage, current limit, phase-break, zerolost, phase sequence, voltage unbalance, and current unbalance protections.

9. Function Settings

9.1. General Setting Procedure

  1. Long press and hold the setting button (gear icon) to enter the setting status display page. The set data bits will flash.
  2. Use the up and down buttons to set the content of the flashing bit.
  3. Short press the setting key to switch to the next setting bit.
  4. Short press OK to confirm the settings on the current page and jump to the next settings page.
  5. Long press OK to exit the setting state and save the settings.

9.2. Detailed Parameter Settings

The following tables detail the various protection functions and their adjustable parameters.

Table detailing voltage-related protection settings for the circuit breaker.
Voltage-related protection settings, including delay, upper/lower voltage limits, and under/over voltage protection delay.
Table detailing current-related protection settings for the circuit breaker.
Current-related protection settings, including overload delays, upper/lower current limits, uneven voltage/current balance protection, and phase sequence protection.

10. Maintenance

  • Regularly check all wiring connections to ensure they are tight and secure. Loose connections can lead to poor contact and potential damage.
  • Keep the device clean and free from dust and debris to ensure proper ventilation and operation.
  • If the device requires repair, always disconnect the front stage power supply before attempting any work, as the product does not have an isolation function.

11. Troubleshooting

11.1. Fault Record

The device records instances of overvoltage, undervoltage, overload, low current protection, voltage imbalance, current imbalance, and phase sequence protection. These records can be accessed via the Tuya App.

11.2. WiFi Connection Issues

  • WiFi indicator 1 flash: The device is waiting for a WiFi signal to be detected. Ensure your router is on and within range.
  • WiFi indicator 2 slow flashes: The device is offline. Check your WiFi network status and re-attempt connection via the Tuya app.
  • No connection: Ensure you are long-pressing the setting button on the device to enter WiFi configuration mode before attempting to pair with the app.

12. User Tips

  • For initial WiFi setup, make sure to long-press the setting button on the device until the WiFi indicator starts flashing, then proceed with the Tuya app pairing process.
  • Regularly check the Tuya app for firmware updates to ensure optimal performance and access to new features.

13. Warranty and Support

13.1. Guarantee Period

  • Within 12 months from the date of production: If there are any product quality issues and the strip is intact, our factory will provide free replacement.
  • Within 36 months: If there are product quality issues and the seal is intact, our factory will provide free repair.

13.2. Further Assistance

For further assistance, technical support, or warranty claims, please contact your retailer or the manufacturer directly.

A PDF version of the user manual is available for download: User manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?