PowMr HHJ-60A

Contents

PowMr MPPT 60A Solar Charge Controller User Manual

Model: HHJ-60A

1. Important Safety Information

Please save these instructions.

This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information:

IconDescription
WARNINGIndicates a potentially dangerous condition. Use extreme caution when performing this task.
CAUTIONIndicates a critical procedure for safe and proper operation of the controller.
NOTEIndicates a procedure or function that is important to the safe and proper operation of the controller.

1.1 General Safety Information

  • Read all of the instructions and cautions in the manual before beginning the installation.
  • There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair the controller.
  • Do NOT allow water to enter the controller.
  • Make sure all connections going into and from the controller are tight.

1.2 Charge Controller Safety

  • NEVER connect the solar panel array to the controller without a battery. Battery must be connected first.
  • Ensure input voltage does not exceed 160 VDC to prevent permanent damage. Use the Open Circuit Voltage (Voc) to make sure the voltage does not exceed this value when connecting panels together.

1.3 Battery Safety

  • Use only sealed lead-acid, flooded, gel or lithium batteries which must be deep cycle.
  • Explosive battery gases may be present while charging. Be certain there is enough ventilation to release the gases.
  • Be careful when working with large lead acid batteries. Wear eye protection and have fresh water available in case there is contact with the battery acid.
  • Carefully read battery manuals before operation.
  • Do NOT let the positive (+) and negative (-) terminals of the battery touch each other. Recycle battery when it is replaced.
  • Over-charging and excessive gas precipitation may damage the battery plates and activate material shedding on them. Too high of an equalizing charge or too long of one may cause damage. Please carefully review the specific requirements of the battery used in the system.
  • Equalization is carried out only for non-sealed / vented/ flooded / wet cell lead acid batteries.
  • Do NOT equalize VRLA type AGM / Gel / Lithium cell batteries UNLESS permitted by battery manufacturer.

WARNING

Connect battery terminals to the charge controller BEFORE connecting the solar panel(s) to the charge controller. NEVER connect solar panels to charge controller until the battery is connected.

Do NOT connect any inverters or battery charger into the load terminal of the charge controller.

Once equalization is active in the battery charging, it will not exit this stage unless there is adequate charging current from the solar panel. There should be NO load on the batteries when in equalization charging stage.

2. Overview

The PowMr MPPT series solar charge controller is based on advanced Maximum Power Point Tracking (MPPT) technology, designed for solar systems. It boasts a charge controller conversion efficiency of up to 97%.

PowMr MPPT 60A Solar Charge Controller with key features

Image: PowMr MPPT 60A Solar Charge Controller highlighting 60A Max Charge Current, 12V-48V Battery Voltage Range, 160VDC Max PV Input, and ≥99% PV Utilization.

2.1 Key Features

  • MPPT 60A solar charge controller
  • 100% MPPT technology
  • Built-in DSP controller with high performance for fast digital signal processing
  • Automatic switch for 12V/24V/36V/48V battery bank
  • 3-stage charging optimizes battery performance (Equalize, Boost, Float)
  • Comprehensive protection features: Overcharge protection, input PV polarity reverse protection, output limited current protection, over-temperature protection, PV over current, PV short circuit, battery over voltage, battery over discharge, load over current, load short circuit.
  • Troubleshooting promotion function
  • Suitable for battery types such as sealed lead acid, vented gel, NiCd, and lithium battery.
  • Easy to be mounted

Video: Product introduction highlighting 60A charging current, 99.9% MPPT efficiency, DSP controller, wide system voltage range (12V/24V/36V/48V), segmented charging, built-in protections, fault diagnosis, and compatibility with lithium-ion and lead-acid batteries.

3. Installation and Setup

3.1 Dimensions

Controller dimensions and internal components

Image: The controller measures 21.4cm (8.43in) in length, 11.5cm (4.53in) in width, and 5cm (1.97in) in height. Internal components include Capacitance and Copper Coil Transformer.

3.2 Instruction Notes

CAUTION: Please use only the provided screws. Using other screws may damage the internal PCB due to strong torque. Ensure proper torque when pushing screws into the casing.

Wiring Sequence:

  1. Connect the batteries (1st step): Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (marked with the battery symbol). If the system is 12V, ensure your battery voltage is more than 12V for the controller to boot up.
  2. Connect the solar panel (2nd step): Ensure that the PV modules are protected from incident light. Ensure that the solar panel doesn't exceed the maximum permissible input current. Connect the PV modules connection cable to the correct polarity of the left pair of terminals on the solar charge controller (marked with the PV modules symbol).
  3. Connect loads (3rd step): Connect the load cable to the correct polarity of the right pair of terminals on the solar charge controller (marked with the lamp symbol). To avoid any voltage on the wires, connect the wire to the load before connecting to the controller.
  4. Final check (4th step): Tighten all cables connected to the controller and remove all debris around the controller, leaving a space of approximately 5.91 inches (15cm) for ventilation.
Wiring diagram for solar system components

Image: Wiring diagram showing connections between PV Solar Panels, MPPT Solar Charge Controller, Battery, DC Load, AC Load, and Inverter. It also illustrates support for parallel connection of two 60A controllers to achieve 120A. Max PV Input 160VDC. Max PV Input Power: 12V system (720W), 24V system (1440W), 36V system (2100W), 48V system (2800W).

3.3 Air Circuit Breaker Installation

We strongly recommend connecting a fuse directly to the battery to protect against any short circuit at the battery wiring. Solar PV modules generate current whenever light strikes them. The current varies with light intensity, but even at low light levels, full voltage is present. Protect solar modules from incident light during installation. Never touch uninsulated cable ends, use only insulated tools, and ensure the wire diameter is appropriate for the expected currents of the solar charge controller. Connections must always be made in the sequence described above.

Air Circuit Breaker and Wires Requirement

ModelsCopper wiresAir circuit breakers
MPPT-60A6mm²x2PCS100A

3.4 Connection Reminder

It's better to connect two wires to two PV+ and another two wires to two PV-. For BAT+ and BAT-, it's the same way to connect wires.

  1. Install air circuit breaker between controller and batteries. Turn off the circuit breaker, then connect batteries to controller with correct polarity.
  2. Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity is correct, then connect wires between PV modules and controller.
  3. Turn on the air circuit breaker between controller and batteries.
  4. Turn on the air circuit breaker between controller and PV modules.
  5. The controller goes into the self-test mode. Its LCD displays the parameters if all is correct. And the RUN lamp (under the fan inside of casing) will flash every one second. If the controller is not responsive, please read the full manual again for reinstalling or contact support for help.

4. Operation

4.1 LCD Display

The controller features a backlight LCD screen for displaying various parameters and settings. The main interface shows PV voltage, output power, battery voltage, charging current, working mode, temperature, and fault codes. The sub-interface allows access to settings like Load Timer, Floating Voltage, Absorption Voltage, Battery Type, Under-voltage Disconnection Voltage, and Calibration Voltage.

Detailed LCD display interface and working modes

Image: Detailed LCD display interface showing Battery Voltage, Charging Current, Temperature, Production, Working Mode (Night Mode, MPPT Fashion, Absorption Fashion, Floating Mode), Load Timer, Floating Voltage, Absorption Voltage, Battery Type, Under-voltage Disconnection Voltage, and Calibration Voltage. Also highlights fan cooling and high-airflow exhaust fan design.

Main Interface Display Items:

  1. PV voltage / Output power
  2. Battery voltage / Charging current
  3. Working mode / Temperature
  4. Fault code

Working Modes:

Mode CodeDescription
3.0Night mode, no charging
4.0MPPT mode
7.0Absorption mode
8.0Floating mode

4.2 Battery Charge Voltage Reference

The controller supports various battery types with specific absorption and floating voltage settings. The default settings are suitable for most batteries, except for lithium batteries which require manual adjustment.

Battery TypeAbsorption Voltage (Constant Voltage)Floating Voltage
12V24V48V12V24V48V
Vented14.2V28.6V57.2V13.2V26.4V52.80V
Sealed14.4V28.8V57.6V13.8V27.6V55.2V
Gel14.4V28.8V57.6V13.8V27.6V55.2V
NiCd14.2V28.6V57.2V14.0V28.0V56.0V
Lithium or othersDefined by users

4.3 Manual Settings

Reminder: The controller will work fine under default setting except lithium battery.

CAUTION!

All steps must be carried out when the PV modules are disconnected from the controller.

  1. Step 1: D00 (Load Working Time)
    Press the PRG button, then the LCD displays D00. This is for setting the load working time (Default is 24-hour). Press ENT until numbers flash, then press UP/DOWN to set the desired time. Long-press ENT to confirm. This output voltage is the same as the battery voltage. The load is only for small DC loads less than 5A current. If no load, just leave it.
  2. Step 2: D01 (Floating Voltage)
    Press the UP button, the LCD shows 13.8. This is the default value for floating charging. Press ENT until numbers flash, then press UP/DOWN to set the desired voltage. Long-press ENT to confirm.
  3. Step 3: D02 (Absorption Charging Voltage)
    Continue to press the UP button, the LCD shows 14.5. This is the highest absorption charging voltage for the battery. Press ENT until numbers flash, then press UP/DOWN to set the desired voltage. Long-press ENT to confirm.
  4. Step 4: D03 (Battery Discharge Protection Value)
    Continue to press the UP button, the LCD shows 10.0. This is the protection value for battery discharge. Press ENT until numbers flash, then press UP/DOWN to set the desired voltage. Long-press ENT to confirm. This means the controller is protected when a 12V battery is less than 10.0V, and there is no output power from OU+ and OU-.
  5. Step 5: D04 (Battery Type)
    Continue to press the UP button, the LCD shows 00.00, which is the default for acid batteries. If using a lithium battery, press ENT until numbers flash, then press UP/DOWN to choose 01. Long-press ENT to confirm. Note that Step 2 (D01) is not used when you choose 01 for lithium battery. The voltage set in Step 3 (D02) will be the highest charging voltage for the lithium battery.
  6. Step 6: D05 (Battery Voltage Calibration)
    Continue to press the UP button, the LCD shows C+ "the currently detected battery voltage". This setting item is used to calibrate the battery voltage by adjusting the value, ensuring that the battery voltage detected by the controller matches the actual battery voltage.

Press ESC to exit the setting menu.

Reminder: When you set up all steps, please disconnect the battery. Then reconnect the controller to see if all settings are successful. Once all settings are confirmed, then connect the PV modules to the controller.

CAUTION!

This value is for one 12V battery. If there are many batteries in series, the controller will multiply them in proportion automatically and the LCD only displays the voltage of one battery (For example, if your battery is 4x12V, and if you set the voltage at 14.1, the charge voltage will be 4x14.1 automatically, but the LCD only displays 14.1).

5. Troubleshooting

5.1 Fault Diagnosis System

The controller includes a fault diagnosis system to help identify and resolve issues. The LCD will display specific codes for different problems.

CodeDescriptionHow to solve
18Input PV voltage is lowIncrease the PV voltage
60Over-temperature protectionFan will work and temperature reduction automatically
63Battery voltage is highBattery high voltage protection and wait for recovery
65Battery voltage is lowBattery over-discharge and wait for recovery
71Input PV voltage is highDecrease the PV voltage
73Over-charging currentDecrease the PV power

5.2 Built-in Protections

The controller is equipped with multiple protection mechanisms to ensure safe and reliable operation:

  1. PV Over Current: The controller will limit charging power to the rated charge power. An over-sized PV array will not operate at its maximum power point.
  2. PV Short Circuit: When a PV short circuit occurs, the controller will stop charging. Remove the short circuit to resume normal operation.
  3. PV Reverse Polarity: Full protection against PV reverse polarity is provided, causing no damage to the controller. Correct the connection to start normal operation.
  4. Battery Over Voltage: If other energy sources charge the battery, and the battery voltage exceeds 15.5V (for 12V system), 31.0V (for 24V system), 46.5V (for 36V system), or 62.0V (for 48V system), the controller will stop charging to protect the battery from overcharging damage. (Note: "Stop charging" means the charging current is very low).
  5. Battery Over Discharge: When the battery voltage drops to the set low voltage disconnect point, the controller will stop discharging to protect the battery from over-discharging damage.
  6. Load Over Current Protection: If the load current exceeds 1.25 times the maximum load current rating, the controller will disconnect the load.
  7. Load Short Circuit Protection: Once a load short circuit happens, the load short circuit protection will activate automatically.
  8. Over Temperature Protection: The controller will automatically manage its temperature. The fan will turn on if the temperature exceeds 45°C (104°F) and turn off when it drops below 40°C (95°F). The maximum operating temperature is 75°C (167°F).

6. Specifications

FeatureDetails (HHJ-60A)
Charging mode3-stage: constant current (MPPT), 4-constant voltage, Floating
Max.PV Input Power12V system720W
24V system1440W
36V system2100W
48V system2800W
Input specification DC12V system20V~80V
24V system37V~105V
36V system50V~160V
48V system72V~160V
Battery voltage automatic recognition12V systemDC9V~DC15V
24V systemDC18V~DC29V
36V systemDC30V~DC39V
48V systemDC40V~DC60V
Overcharging protection voltage60V
Limited current protection61A
Max efficiency≥98.1%
PV utilization≥99%
Protection function
Temperature protection75°C / 167°F
Fan-on temperature>45°C / 104°F
Fan-off temperature<40°C / 95°F
Properties
Size (mm)/(in)214x115x50mm / 8.43x4.53x1.97in
Net weight(Kg)/(lb)1.1 / 2.43
Gross weight(Kg)/(lb)1.2 / 2.65
Electromagnetic compatibilityAccord to EN61000, EN55022, EN55024
EnclosureIP21
Environmental temperature-20°C ~ +55°C
Storage temperature-40°C ~ +75°C

7. User Tips

  • Battery Type Setting: Remember that the default settings are suitable for most battery types, but lithium batteries require manual adjustment (Step 5: D04).
  • Battery Voltage Calibration: If you notice discrepancies in battery voltage readings, use the D05 setting to calibrate the battery voltage for accurate display.
  • Post-Setup Check: After completing all manual settings, always disconnect the battery and then reconnect it to the controller to ensure all settings have been successfully applied before connecting the PV modules.
  • MPPT Tracking: If the PV or battery data is constantly changing, do not worry. This indicates the controller is actively finding the Maximum Power Point (MPPT). If this persists or you suspect insufficient PV input power/voltage, contact technical support.
  • PDF Manual: A detailed user manual in PDF format is available for download. You can find it at: PowMr MPPT Solar Charge Controller User Manual (PDF).

8. Warranty and Support

8.1 Warranty Regulations

Any damaged unit caused by the user's failure to install, disassemble, or incorrect use of this product may void maintenance.

  1. Within 30 days from the date of purchase, a faulty controller will be replaced free of charge under normal use (with authorization from technical personnel).
  2. Within 2 years from the date of purchase, a faulty controller will be repaired free of charge.

Notes: Disassembly by unauthorized personnel voids the warranty.

8.2 Liability Disclaimer

The manufacturer shall not be liable for damages, especially to the battery, caused by use other than as intended or as mentioned in this manual, or if the recommendations of the battery manufacturer are neglected. The manufacturer shall not be liable if service or repair has been carried out by any unauthorized person, or due to unusual use, wrong installation, or bad system design.

8.3 Contact Information

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD

  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.