SENNUOPU M2

Contents

Sennuopu M2 Automotive Acoustic Measuring Instrument

Model: M2

Professional Measurement for Sound Systems

Overview

The Sennuopu M2 Automotive Acoustic Measuring Instrument is designed for precise acoustic measurement in automotive audio systems. This is crucial for improving sound quality, optimizing design, and ensuring an optimal user experience.

Acoustic measurements provide accurate and quantified data, such as frequency response, sound pressure level, and distortion, to objectively reflect the performance of a car audio system. This data helps users and professionals understand system performance, identify potential issues, and optimize system design by analyzing sound field distribution. It also ensures product consistency in manufacturing and allows for personalized tuning services based on user preferences.

The M2 is a compact, elegant, and portable instrument, compatible with most audio measurement software including TrueRTA, SMAART V8, SYSTUNE, SAT live, ARTA, REW, and AUDIO TOOL. It is driver-free for Windows/MAC OS X systems and can be used directly after connecting the data cable. It also supports Android and Apple phones. The M2 features one measurement input channel with a 48V phantom power switch and PAD switch, one single-channel output, and one 6.35mm headphone output, ensuring convenient operation.

Package Contents

The Sennuopu M2 package includes the following items:

  • Sennuopu M2 Acoustic Measuring Instrument
  • ECM8000 Measurement Microphone
  • USB Cable
  • XLR Cable
  • RCA Cables
  • Microphone Stand Adapter
  • Portable Carrying Case
Sennuopu M2 package contents including the M2 unit, ECM8000 microphone, various cables, and a carrying case.
Figure 1: Contents of the Sennuopu M2 package.

Interface Description

Familiarize yourself with the various ports and controls on the Sennuopu M2 unit:

Diagram showing the front and rear panels of the Sennuopu M2 with numbered labels for each interface component.
Figure 2: Front and Rear Panel Interface of the M2.
  1. Output Volume Control Knob (VOL): Adjusts the output volume.
  2. Headphone Monitor Output (Stereo Output): 6.35mm jack for monitoring audio.
  3. USB Interface: Connects the M2 to a computer or compatible device.
  4. Power Indicator: Illuminates when the device is powered on.
  5. MIC IN (Measure the Input Channel): XLR input for the measurement microphone.
  6. 48V Phantom Power Indicator: Illuminates when 48V phantom power is active.
  7. 48V Phantom Power Switch: Activates/deactivates 48V phantom power for the microphone.
  8. Input Channel Attenuation 10dB Switch (PAD): Reduces the input signal by 10dB to prevent clipping.
  9. OUT (Output Channel): XLR output for connecting to a DSP or other audio equipment.

Setup Instructions

Device Connection

Follow these steps to connect your Sennuopu M2 and ECM8000 microphone for car audio system measurement:

  1. Connect the ECM8000 acoustic measuring microphone to the MIC IN port of the M2 instrument using an XLR cable.
  2. Press the +48V switch on the M2 to provide phantom power to the microphone. The 48V Phantom Power Indicator will light up.
  3. Connect the OUT port of the M2 instrument to the RCA input of your Digital Sound Processor (DSP) using the provided RCA cables. Ensure your DSP is switched to a low-level input sound source.
  4. Connect the USB Interface of the M2 instrument to your notebook (Windows/MAC OS X) or compatible Android/Apple phone using the USB cable. The Power indicator on the M2 will turn on.
  5. Open your preferred measurement software (e.g., TrueRTA, SMAART V8) on your notebook and configure it to recognize the M2 as the audio interface and the ECM8000 as the input microphone.
  6. Adjust the VOL knob on the M2 to achieve the appropriate volume output for your measurement software.
Step-by-step visual guide for connecting the Sennuopu M2, ECM8000 microphone, DSP, and laptop for car audio measurement.
Figure 3: Detailed connection steps for the M2 system.
Diagram illustrating the complete connection setup for car audio system measurement, showing the M2, ECM8000, DSP, and laptop, with speaker placement in a car interior.
Figure 4: Car Audio System Measurement Connection Diagram.

Software Installation

The Sennuopu M2 is designed to be driver-free for Windows and MAC OS X systems. For measurement software, a program is typically included on a USB drive with your purchase. Insert the USB drive into your computer and follow the on-screen instructions for installation. If you encounter difficulties, refer to the software's specific documentation or contact technical support.

Play video
Watch video online

Video 1: Demonstration of device connection for car audio system measurement.

Operating Instructions

Once the M2 and microphone are connected and your measurement software is ready, you can begin acoustic measurements:

  1. Microphone Placement: Position the ECM8000 microphone at various listening positions within the car cabin to capture accurate sound field data.
  2. Software Configuration: In your chosen measurement software, select the Sennuopu M2 as your audio input/output device. Configure the software for Real-Time Analysis (RTA) or other desired measurement types.
  3. Signal Generation: Use the software to generate test signals (e.g., pink noise, sweeps) through your car audio system.
  4. Data Acquisition: The microphone will capture the sound, and the M2 will transmit the data to your software for analysis.
  5. Analysis and Adjustment: Analyze the frequency response, phase, and other acoustic parameters displayed by the software. Use this data to make adjustments to your DSP settings, speaker placement, or sound insulation to optimize the audio system.
  6. Monitoring: Use the headphone output on the M2 to monitor the audio signal during measurements.

User Tips

  • Software Source: Always check the included USB drive for the measurement software and any necessary drivers.
  • Calibration: While the device is designed for professional use, consider performing a microphone calibration within your software for the most precise measurements, especially if calibration data is not explicitly provided.
  • Loopback Functionality: Note that the M2 features a single-channel input and output and does not include an internal loopback function. External loopback may be required for certain measurement types.

Specifications

Sennuopu M2 Acoustic Measuring Instrument

FeatureSpecification
THD+N≤0.03%
Dynamic range (weighted by A)86dB
Input impedance3.3KΩ
Output impedance50Ω
Maximum output level+4dB
Frequency response±0.9dB (20Hz-20KHz)
Ear amplification thrust200mW/32Ω
Weight336g
Dimensions (L×W×H)120mm × 80mm × 50mm

ECM8000 Measurement Microphone

FeatureSpecification
TypeElectret Condenser
Polar PatternOmnidirectional
Impedance200 Ohms
Sensitivity70 dB
Frequency Response20-20000Hz
ConnectorGold-plated XLR
Phantom Power+15 to +48V
Weight136g

Troubleshooting

  • No Power Indicator: Ensure the USB cable is securely connected to both the M2 and your computer/device. Try a different USB port or cable.
  • Microphone Not Detected: Verify the XLR cable is firmly connected to the MIC IN port and the microphone. Ensure the +48V phantom power switch is ON and its indicator is lit.
  • No Sound Output/Input in Software: Check your measurement software's audio device settings to ensure the Sennuopu M2 is selected as both the input and output device. Adjust the VOL knob on the M2.
  • Software Installation Issues: If you have difficulty installing the measurement software from the provided USB drive, ensure your operating system is compatible. For persistent issues, refer to the software's documentation or contact Sennuopu support.
  • Distorted Audio: If the audio signal is distorted, try engaging the PAD switch on the M2 to attenuate the input signal by 10dB. Reduce the input gain within your software if available.

Frequently Asked Questions (FAQ)

Q: What measurement programs are compatible with the M2?
A: The M2 is compatible with most audio measurement software such as TrueRTA, SMAART V8, SYSTUNE, SAT live, ARTA, REW, and AUDIO TOOL.
Q: Can I measure electrical signals directly from amplifier outputs?
A: The Sennuopu M2 is primarily designed for acoustic measurements using the ECM8000 microphone. It is not intended for direct electrical signal measurement from amplifier outputs.
Q: Does the M2 have an internal loopback function?
A: The M2 features one measurement input channel and one single-channel output, but it does not have an internal loopback function.

Warranty & Support

The limited warranty complies with legal regulations. Failures or damages caused by overload or improper use are not covered by the warranty. Please return the defective product only with a valid proof of purchase and a detailed malfunction description. Technical specifications are subject to change without prior notice. Errors are reserved. For damages to the vehicle and the device caused by handling errors of the device, we cannot assume liability.

Contact Information

Manufacturer: Guangzhou Nisson Automobile Products Co., Ltd.

E-mail: sennuopu@nisson-auto.com

Website: https://www.sennuopu.com

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.