1. Product Overview
The NOKLEAD 5253 is a digital thermohygrometer designed to accurately monitor indoor temperature and humidity levels. It features a large LCD display, multiple mounting options, and a comfort level indicator to help you maintain a healthy and comfortable indoor environment.

Figure 1: Device display showing temperature, humidity, time, date, and comfort level.
Key Features:
- Large LCD Display (88.84mm)
- Temperature and Humidity Monitoring
- Comfort Level Indicator (DRY, COMFORT, WET)
- °C/°F Switchable
- 12/24 Hour Time Display
- Date Display
- Fast 10-second Refresh Rate
- Multiple Mounting Options: Strong Magnet, Wall Stick, Durable Stand
- Powered by CR2032 Button Battery

Figure 2: Overview of device features.
2. Setup
2.1 Before First Use
Locate the battery compartment on the back of the device. Pull out the plastic insulation tab from the battery compartment to activate the pre-installed battery.
2.2 Installing/Replacing Battery
- Open the battery compartment cover on the back of the device.
- Insert one CR2032 button battery, ensuring the correct polarity (+ side up).
- Close the battery compartment cover securely.
- When the screen becomes dim or blank, it's time to replace the battery.
2.3 Mounting Options
The NOKLEAD 5253 offers versatile placement options:
- Magnetic Attachment: The device has a built-in magnet, allowing it to be directly attached to any metallic surface (e.g., refrigerator).
- Wall Mounting: Use the provided adhesive pad. Stick one side of the pad to the iron plate on the back of the humidity meter, then stick the other side to your desired non-metallic wall surface.
- Desktop Stand: Utilize the built-in foldable stand to place the device upright on any flat surface like a desk or shelf.

Figure 3: Multiple mounting options.
3. Operating Instructions
3.1 Date and Time Setting
- In normal display mode, press and hold the SET button for 3 seconds to enter the setting mode. The year number will begin to flash.
- Press the SET button repeatedly to adjust the year.
- After setting the year, press SET again. The month number will flash. Press SET to adjust the month.
- Repeat this process for setting the Day, Hour, and Minute.
- After setting the minutes, press SET to confirm all settings and exit the time setting mode.
- If no operation is performed for 15 seconds during setting, the device will automatically exit the setting mode.
3.2 12/24 Hour Time Format
In normal display mode, briefly press the SET button to switch between 12-hour and 24-hour time formats.
3.3 Celsius/Fahrenheit Selection
In normal display mode, briefly press the °C/°F button to switch the temperature unit between Celsius (°C) and Fahrenheit (°F).
3.4 Comfort Level Indicator
The device features a visual comfort level indicator bar on the display, categorized as:
- DRY: Humidity below 30%
- COMFORT: Humidity between 30% and 69% (inclusive)
- WET: Humidity 70% or above

Figure 4: Practical Comfort Level Indicator.
3.5 Calibration (Advanced)
If you believe the readings are inaccurate, you can calibrate the device:
- Press and hold the SET and °C/°F buttons simultaneously for 3 seconds to enter calibration mode. The temperature number will begin to flash.
- Press the SET button to adjust the temperature value.
- Press the °C/°F button to switch to humidity calibration. The humidity number will begin to flash.
- Press the SET button to adjust the humidity value.
- To save your calibration and exit, press and hold the SET button for 3 seconds.
- If no operation is performed for 15 seconds, the device will automatically exit calibration mode without saving.
Note: Calibration settings will be cleared if the battery is removed.
4. Maintenance and Precautions
4.1 Battery Care
- Only use CR2032 button batteries. Do not mix different types of batteries.
- If the device will not be used for an extended period, remove the battery to prevent leakage.
- Replace the battery when the screen display becomes dim or blank.
4.2 Cleaning
Wipe the surface of the device with a soft, dry cloth. Do not use corrosive liquids, abrasive cleaners, or chemical solvents, as these may damage the display or casing.
4.3 General Precautions
- This product is not waterproof. Do not immerse it in water or use it in environments with extremely high humidity (e.g., directly in a shower).
- Avoid dropping the product from a high place, as this may cause damage.
- Do not expose the unit to extreme temperatures (hot or cold) or direct sunlight for prolonged periods, as this can affect accuracy and device lifespan.
- Keep out of reach of children.
5. Troubleshooting
- Display is dim or blank: The battery may be low or depleted. Replace the CR2032 battery.
- Readings seem inaccurate:
- Ensure the device is not placed near heat sources (e.g., radiators, direct sunlight) or cold sources (e.g., air conditioning vents, open windows) that could affect local readings.
- Ensure proper air circulation around the device.
- Perform a calibration as described in Section 3.5.
- Buttons are unresponsive: Remove and reinsert the battery to reset the device. If the issue persists, contact customer support.
6. Specifications
| Feature | Specification |
|---|---|
| Model | 5253 |
| Temperature Range | -9.9°C to 60°C (14.2°F to 140°F) |
| Temperature Accuracy | ±1°C |
| Humidity Range | 10% to 95% RH |
| Humidity Accuracy | ±5% RH |
| Refresh Rate | 10 seconds |
| Display Type | Digital LCD |
| Display Size | 88.84mm (diagonal) |
| Power Source | 1 x CR2032 Button Battery |
| Battery Life | 6-12 Months (typical) |
| Product Dimensions | Approx. 81 x 70 x 14 mm |
| Product Weight | Approx. 84g |
| Certification | CE |

Figure 5: Accuracy specifications and environmental monitoring.
7. User Tips
- For the most accurate readings, place the thermohygrometer in a central location within the room, away from direct sunlight, drafts, or heat sources.
- Allow the device about 15-30 minutes to stabilize after placement or battery change to get accurate readings of the ambient environment.
- Regularly check the comfort level indicator to ensure your indoor environment is within the optimal range (30-69% humidity) for health and comfort.
8. Warranty and Support
8.1 Money-Back Guarantee
NOKLEAD offers a 60-Day Money-Back Guarantee. You may return your undamaged product and packaging within 60 days of purchase to receive a full refund for any reason.
8.2 Product Warranty
This product is covered by an 18-Month Warranty for quality-related issues. NOKLEAD will take care of all quality-related issues with a replacement or full refund.
8.3 Customer Support
For any questions, concerns, or warranty claims, please contact our customer service team:
Email: support@noklead.com
Please have your order number and product model (5253) ready when contacting support for faster service.
For additional information or to download the original user manual, please refer to the official product page or the provided PDF document: User Manual (PDF)