PowMr POW-M60-MAX

Contents

PowMr MPPT 60A Solar Charge Controller User Manual

Model: POW-M60-MAX | Brand: PowMr

1. Introduction

Thank you for choosing the PowMr MPPT Solar Charge Controller. This controller utilizes numerical control technology and an LCD display for automatic operation. Its Maximum Power Point Tracking (MPPT) battery charging mode and advanced control technology are designed to significantly extend battery life.

The controller features a smart tracking algorithm that maximizes energy harvesting from solar PV modules to charge the battery. It is suitable for independent solar energy systems, automatically managing the charging and discharging processes. The optimized battery charging and discharging process prolongs battery life and enhances system performance. Built-in self-diagnostics and electronic protection functions prevent damage from installation errors and system failures.

The POW-M60-MAX model includes a user-friendly LCD screen display algorithm, allowing all parameters to be displayed, monitored, and configured through a single interface. This model has been optimized and upgraded to provide an improved user experience.

PowMr MPPT 60A Solar Charge Controller with key features highlighted: Bigger LCD Screen, Plug & Play Connection, Battery Activation, MPPT 60A.

Figure 1: PowMr MPPT 60A Solar Charge Controller with highlighted features.

2. Important Safety Instructions

WARNING: CAREFULLY READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  • Carefully read the manual before installation and operation; retain for future reference.
  • The controller must not be installed or operated by persons lacking appropriate knowledge, experience, or competence, or by those with compromised physical, sensory, or mental capabilities, unless under strict instruction and supervision.

Controller Installation and Operation Safety

  • There are no serviceable parts for this controller. DO NOT disassemble or attempt to repair.
  • Install in a location with good natural airflow/ventilation and sufficient unobstructed space (refer to Section 3.2 for details).
  • Install on a non-flammable substrate, ensuring no heat-sensitive items are nearby. The controller may become hot during operation.
  • Protect from direct sunlight, water, high moisture, and dust. Keep away from flammable liquids or gases. For indoor use only.
  • Do not install or operate on top of or directly above the battery, or in a sealed compartment with the battery, as batteries can emit explosive gases.
  • Do not cover or place other items on top of the controller.

Battery Installation and Charging Safety

  • Install and charge the battery in a location with good natural airflow/ventilation.
  • Ensure no ignition sources are near the battery; batteries can emit explosive gases.
  • Battery acid is corrosive; if contact occurs, immediately rinse skin with water.
  • Do not charge non-rechargeable batteries or Li-ion batteries if the temperature is below 0°C. Never charge a frozen battery.
  • Ensure the unit is properly set up for the type of battery intended to be charged.

Battery DC Connections Safety

  • Ensure the DC system is fully shut down/isolated before disconnecting existing cabling or making new connections.
  • Use flexible multi-stranded copper cable with sufficient cross-sectional area and an appropriate fuse or circuit breaker (refer to Section 3.4 for details).
  • NEVER connect the solar panel array to the controller without a battery. The battery must be connected first.

Controller Setup Safety

  • Refer to battery manufacturer instructions for compatibility and recommended charge settings.
  • The integrated charge modes are suitable for most common battery types: flooded lead-acid, Gel, and LiFePO4.

3. Setup and Installation

3.1 Unpacking and Inspection

Before unpacking, check for package damage. After unpacking, verify contents are undamaged and complete. The package should contain:

  • PowMr MPPT Solar Charge Controller
  • User manual
  • Screws/bolts for mounting
  • Special cables with terminals
  • Special cable terminals

Video 1: Unboxing and initial setup overview of the PowMr POW-M60-MAX.

Contents of the PowMr MPPT Solar Charge Controller package, including the controller, user manual, and various cables and terminals.

Figure 2: Package contents of the PowMr MPPT Solar Charge Controller.

3.2 Preparing for Installation

The controller is designed for wall mounting using the flanges on either side of the heatsink.

Select the Mount Location:

Consider the following for a suitable and safe installation location:

  • Good natural airflow/ventilation.
  • Sufficient unobstructed space around the controller; a minimum clearance of 75mm above and below is recommended.
  • Non-flammable substrate with no heat-sensitive items nearby.
  • Protected from direct sunlight, water, high moisture, and dust.
Diagram showing recommended clearances for installing the solar charge controller, with 75mm space above and below.

Figure 3: Recommended installation clearances for the controller.

3.3 Things You Need

Ensure you have the following parts for installation:

Product Quantity
POW-M60-MAX Controller 1
DC-cable for positive DC connection (+) 3
DC-cable for negative DC connection (-) 3
DC breaker 3
Screws / bolts (Ø5mm) for mounting 4
PV array (refer to Section 3.5) 1
Battery pack 1

NOTICE:

  • For all wiring and circuit specifications, refer to Section 3.4 DC Breaker Type.

3.4 DC Breaker Type

PV input circuit breaker type: Determine based on configured system voltage and "6. Technical Specification". Note: Voltage in series must not exceed maximum PV input open-circuit voltage.

Recommended specifications for DC circuit breakers for load output circuit:

Model Max. DC output Current Circuit Breaker Spec
POW-M60-MAX 30A 2P-32A

The DC circuit breakers for the battery should be selected based on the maximum charging current of the connected battery.

3.5 PV Module Selection

When selecting PV modules, consider the following:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the controller.
  2. Open circuit Voltage (Voc) of PV modules should be higher than the Min. battery voltage.
Controller mode POW-M60-MAX
Max. PV array open circuit voltage of controller 160V

3.6 Wiring Precautions

  • Installation and connection work must be performed by a licensed electrician.
  • Tighten all connections well to prevent dangerous overheating from loose connections. Use cables of the correct size (refer to Section 3.4).
  • Install separate circuit breakers for each circuit to enhance safety and facilitate maintenance.
  • Do not connect the inverter to the load side of the controller to avoid irreversible damage. If an inverter is needed, refer to the system application diagram below.
Wiring diagram for the PowMr MPPT Solar Charge Controller, showing connections for PV array, battery, and load, including circuit breakers and an optional inverter.

Figure 4: System application wiring diagram for the controller.

3.7 Installation and Connection Step-By-Step

  1. Mark the mounting spots on the wall using the controller's mount holes as a template. Drill 4 mounting holes.
  2. Insert expansion rubber screw plugs into the mounting holes.
  3. Mount the controller vertically with terminals facing down. Secure using the 4 mounting holes/slots on the base. It is recommended to hang the unit using the 2 upper screws first, then add the 2 lower screws, and finally secure all 4 screws. Recommended screw size is M5.
  4. Battery Connection: Connect the battery to the controller with the cables.
  5. PV Connection: Connect the PV array to the controller with the cables.
  6. DC Output Connection: Connect the load to the controller with the cables.
  7. Check before starting up: Refer to the wiring diagram below. If all wires are firmly connected, close the circuit breakers at the battery side, PV module side, and load side in sequence to start the controller.
Detailed connection diagram for the PowMr MPPT Solar Charge Controller, showing connections for PV array, battery, and load.

Figure 5: Detailed connection diagram.

WARNING: Risk of electric shock!

  • Make sure all power is turned off before performing any operations, then follow inspections and operations.

4. Operation Instructions

4.1 Charging Mode

The charging controller features an intelligent 3-stage charge characteristic for optimal battery charging. Upon startup, the controller always begins at the Bulk stage.

The three integrated charge modes (Bulk, Constant, Float) ensure fast, efficient, and safe battery charging, extending battery life. These modes, combined with adaptive charge logic, are well-suited for most common battery types, including flooded lead-acid, Gel, and LiFePO4.

Charging mode parameters can be set via the LCD screen. Any settings made are stored and will not be lost if the controller is disconnected from the battery or PV module.

Multi-stage Charge Algorithm:

  • Bulk charge: Battery charges at maximum current until voltage reaches the configured boost charge voltage. Duration depends on battery discharge level, capacity, and charge current.
  • Boost charge: Battery charges at the configured boost charge voltage, with current slowly decreasing as the battery approaches full charge. The default boost stage duration is adaptive, determined by the battery's discharge level. If the PV module is reconnected, a new charging cycle starts. If the battery is full, it directly enters stage B (boost charging voltage stage) for 30 minutes.
  • Float charge: After boost charging, the controller reduces current to maintain the battery at the floating charging voltage, keeping it fully charged. Loads can draw almost all power from the solar panel during this stage. If loads exceed power, the controller may not maintain float voltage. If battery voltage drops below Recharge Voltage, it returns to Bulk charging.

4.2 LCD Screen Display and Function Keys

The LCD screen provides various icons and numerical displays for monitoring and configuration.

LCD screen display of the PowMr MPPT Solar Charge Controller showing PV input, battery status, and load status icons and values.

Figure 6: LCD screen display overview.

No. Function
1 Day or night indicating icon
2 Indicates the remaining battery capacity
3 Working mode (See Section 4.4)
4 Periodic running status of the load and warning state (See Section 5.2 Troubleshooting)
5 Indicate PV input voltage/power
6 Indicate Current battery voltage/Charging current/Equipment temperature/Battery calibration voltage/Battery type/Boost charging voltage/Float charging voltage/Low DC cut-off recovery voltage/ Low DC cut-off voltage.
7 Indicate working mode of load.

Function Keys:

Image showing the four function buttons on the controller: PV, BAT/A, DC/V, SET/gear icon.

Figure 7: Controller function keys.

Icon Description
PV/ To switch the PV input parameters information
BAT / To switch the charging information/ Return the previous option.
DC / To adjust DC output mode and DC output operation duration/ Enter the next option.
SET/ Confirm and reserve the settings.

4.3 Browse and Configuration Step-By-Step

After connecting cables and starting the device, perform initial configuration based on your specific setup.

NOTICE:

  • The screen backlight automatically turns off after about 25 seconds of inactivity to save power. Press any key to reactivate.

4.3.1 PV Side Information

Press the "PV/" key to switch between PV input voltage and PV input power information.

4.3.2 Battery Side Information

Press the "BAT /" key to cycle through battery information: current battery voltage, charging current, equipment temperature, battery calibration voltage, battery type, boost charging voltage, float charging voltage, low DC recovery cut-off voltage, and low DC cut-off voltage.

4.3.3 Calibrate Battery Voltage

The battery calibration voltage parameter corrects the current battery voltage measured by the controller.

  1. When the display shows "battery calibration voltage", press and hold "BAT /" to enter calibration setting.
  2. Press "BAT /" or "DC /" to adjust the voltage to match a multimeter reading.
  3. Finally, press "SET/" to confirm.

4.3.4 Select Battery Type

Adjust battery type parameters based on your connected battery.

  1. When the display shows the battery type item, press and hold "BAT /" to enter the battery type adjustment setting.
  2. Press "BAT /" or "DC /" to adjust the battery type.
  3. Finally, press "SET/" to confirm. The operating voltage varies by battery type.

Refer to Section 4.5.2 for detailed battery parameters for different types.

4.3.5 Customize Configured Voltage Parameters

NOTICE:

  • This step is only required if the battery type is set to "USE" (User-defined).

If "USE" is selected, configurable parameters are presented in the following order. Each click increments by 0.1V.

  • Nominal system voltage (12V/24V/36V/48V optional)
  • Boost charging voltage (10.0~17.0V)
  • Float charging voltage (10.0~17.0V)
  • Low DC cut-off recovery voltage (10.0~15.0V)
  • Low DC cut-off voltage (10.0-15.0V)

Use "BAT /" to select the parameter, hold "BAT /" to enter adjustment, use "BAT /" or "DC /" to change value, then "SET/" to confirm.

WARNING:

  • Settings must follow this logic: Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage.

4.4 Working Mode

Code Description
3.0 Night mode, no charging
4.0 Bulk charging mode (MPPT mode)
7.0 Boost charging mode
8.0 Float charging mode

4.5 Key Points Battery Parameter Settings

4.5.1 Logic for Setting Battery Voltage Parameters

Before customizing battery parameters, confirm the following for the connected battery:

  • Max charging voltage
  • Discharging protection voltage

After confirming battery information, set the 4 key parameters according to this logic:

Max. charging voltage > Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage > Discharge protection voltage

4.5.2 Battery Parameters of Different Types

For lead-acid battery & User define:

Parameter FLd GEL SEL USE
Boost charging voltage 14.6V 14.2V 14.4V 10.0~17.0V
Float charging voltage 13.8V 13.8V 13.8V 10.0~17.0V
Low DC cut-off voltage 11.0V 11.0V 11.0V 10.0~15.0V
Low DC cut-off recovery voltage 12.6V 12.6V 12.6V 10.0~15.0V

For Ternary lithium battery:

Parameter N03 N06 N07 N13 N14
Boost charging voltage 12.5V 25.0V 29.2V 54.2V 58.3V
Float charging voltage 12.2V 24.4V 28.5V 52.9V 56.9V
Low DC cut-off voltage 8.4V 16.8V 19.6V 36.4V 39.2V
Low DC cut-off recovery voltage 9.0V 18.0V 21.0V 39.0V 42.0V

Lithium iron phosphate battery:

Parameter L04 L07 L08 L15 L16
Boost charging voltage 14.5V 25.4V 29.0V 54.4V 58.0V
Float charging voltage 13.8V 24.1V 27.6V 51.8V 55.2V
Low DC cut-off voltage 11.2V 19.6V 22.4V 42.0V 44.8V
Low DC cut-off recovery voltage 12.0V 21.0V 24.0V 45.0V 48.0V

5. Protection Features

The controller includes various protection mechanisms to ensure safe and reliable operation.

Protection Behavior
PV Array Short Circuit Controller stops charging. Clear the short circuit to resume normal operation.
PV Input Overcurrent Controller limits battery charging current to maximum rating. Overcurrent solar array will not operate at peak power.
Controller Overload If current exceeds 21A, controller disconnects load. Reduce load and restart controller to clear.
Load Short Circuit Fully protected. If load short circuit (more than quadruple rated current) occurs, protection activates. After 5 automatic reconnect attempts, restart controller to clear faults.
PV Reverse Polarity Controller will not operate. Correct wiring to resume normal operation.
Battery Reverse Polarity Controller will not operate. Correct wiring to resume normal operation.
Over-Temperature If heatsink temperature exceeds 65°C, charging current reduces. Shuts down if temperature exceeds 80°C.

6. Troubleshooting

In case of a failure, the controller display shows an error signal to help you find its source.

Fault code Possible Cause What to do
18 Input PV voltage is low Increase the number of photovoltaic panels; or increase the photovoltaic input voltage value in series.
60 Over-temperature protection When the temperature of the device is cooled below the recovery temperature, normal charge and discharge control is resumed.
63 Battery voltage is high Measure whether the battery voltage exceeds the rated voltage and turn off the photovoltaic array air switch.
65 Battery voltage is low Charge the battery and wait until the battery voltage is higher than the low voltage cut-off voltage recovery point, refer to "4.5.2 Battery parameters of different types" section for detail.
71 Input PV voltage is high Reduce the number of PV panels connected to the controller to reduce the PV input; or reduce the voltage or current value by changing the series or parallel mode.
73 Over-charging current Reduce the voltage or current value by changing the series or parallel mode.

7. Maintenance

Perform the following inspections and maintenance tasks at least twice a year for optimal performance:

  • Ensure the controller is firmly installed in a clean and dry environment.
  • Ensure no obstructions to airflow around the controller. Clean any dirt or fragments from the radiator.
  • Check all exposed wires for insulation damage (solarization, frictional wear, dryness, insects, rats, etc.). Repair or replace damaged wires as necessary.
  • Tighten all terminals. Inspect for loose, broken, or burnt wire connections.
  • Confirm all system components are properly grounded.
  • Confirm all terminals have no corrosion, insulation damage, high temperature, or burnt/discolored signs. Tighten terminal screws to the suggested torque.
  • Check for dirt, nesting insects, and corrosion. Clear promptly if found.

WARNING: Risk of electric shock!

  • Make sure all power is turned off before performing any maintenance operations, then follow the corresponding inspections and operations.

8. Specifications

Category Parameter POW-M60-MAX
PV Input Max. Input Power (12V system) 720W 20-80Vdc
Max. Input Power (24V system) 1440W 37-105Vdc
Max. Input Power (36V system) 2100W 50-160Vdc
Max. Input Power (48V system) 2800W 72-160Vdc
Input Voltage Range (all systems) 20V~160V (system dependent)
Charge Mode Charging Technology MPPT
Charge Algorithm 3-Stage
Nominal System Voltage 12V/24V/36V/48V
Battery Voltage Range 9~70V
Rated Charging Current 60A
Efficiency Conversion Efficiency ≥98%
MPP Tracking Efficiency ≥99%
Self-consumption 0.7W-1.2W
DC Output Rated Output Current 25A
Max. DC Output Current 30A
Max. Capacitive Load Capacity 10000μF
Environment & General Operating Temperature Range -35°C ~ +45°C
Humidity Range ≤95%, Non-condensing
Altitude <3000m
Protection Class IP32
Physical Dimension (L*W*H) 230*165*72mm (9.1*6.5*2.8in)
Net Weight 1.45kg (3lbs)

9. User Tips

  • Always double-check battery compatibility and voltage settings before connecting to prevent damage.
  • Ensure all wiring connections are secure and correctly polarized to avoid operational issues and potential hazards.
  • Regularly monitor the LCD display for system status and any fault codes to ensure optimal performance and address issues promptly.
  • For best performance, ensure adequate ventilation around the controller to prevent overheating, especially in warmer climates.

10. Warranty and Support

For technical support or warranty inquiries, please contact PowMr directly:

  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

A PDF version of this user manual is available for download: PowMr Solar Charge Controller User Manual (PDF).

© 2024 PowMr. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.