1. Important Safety Instructions

WARNING: CAREFULLY READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  • Carefully read the manual before the controller is installed and operated; retain the manual in a safe place for future reference.
  • The controller must not be installed or operated by any of the following persons, unless they are under strict instruction and supervision:
    • Anyone who lacks the appropriate knowledge, experience or competence, required for safe installation and/or usage.
    • Anyone with compromised/reduced physical, sensory or mental capabilities, which may effect safe installation and/or usage (including children).
  • Controller installation and operation
    1. There are no serviceable parts for this controller. Do NOT disassemble or attempt to repair the controller.
    2. Install the controller in a location with good natural airflow/ventilation and sufficient unobstructed space around it; refer to the "2 Installation and Connection" section for more detail.
    3. Install the controller on a non-flammable substrate and ensure there are no heat-sensitive items in the immediate vicinity; it is normal for the controller to become hot during operation.
    4. Install the controller in a location where it is protected from environmental conditions such as direct sunlight, water, high moisture and dust, and also located well away from any flammable liquids or gasses. Controller is for indoor use only.
    5. Do not install or place/operate the controller on top of the battery, directly above the battery, or in a sealed compartment with the battery; batteries can emit explosive gasses.
    6. Do not cover or place any other items on top of the controller.
  • Battery installation and charging
    1. Install and charge the battery in a location with good natural airflow/ventilation.
    2. Ensure that there are no ignition sources near the battery; batteries can emit explosive gasses.
    3. Battery acid is corrosive; if battery acid comes into contact with skin immediately rinse with water.
    4. Do not charge non-rechargeable batteries or Li-ion batteries if the battery temperature is below 0°C. Never charge a frozen battery.
    5. Ensure that the unit is properly set up for the type of battery intended to be charged.
  • Battery DC connections
    1. Ensure that the DC system is fully shut down/isolated prior to disconnection of any existing cabling and/or new connections are made to the battery/DC system.
    2. Use flexible multi stranded copper cable with sufficient cross sectional area, line with an appropriate fuse or circuit breaker; refer to the "2.4 Wiring Specification and Breaker Type" section for more detail.
    3. NEVER connect the solar panel array to the controller without a battery. Battery must be connected first.
  • Controller setup
    1. Refer to the battery manufacturers instructions and specifications to ensure the battery is suitable for use with this controller and confirm the recommended charge settings.
    2. The integrated charge modes combined with adaptive charge logic are well suited for most common battery types; such as flooded lead-acid, Gel and LiFePO4.

2. Product Overview and Features

The PowMr 60A MPPT Solar Charge Controller (POW-M60-ULTRA) utilizes numerical control technology design, an LCD display, and automatic operation. Its Maximum Power Point Tracking (MPPT) battery charging mode and advanced control technology significantly extend battery life. The controller features a smart tracking algorithm that maximizes energy harvest from solar PV modules to charge the battery.

This controller is suitable for independent solar energy systems, automatically managing the charging and discharging processes. Its optimized battery charging and discharging prolong battery life and enhance system performance. Self-diagnostics and electronic protection functions prevent controller damage from installation errors and system failures. The humanized LCD screen display algorithm allows all parameters to be monitored and configured on a single layer of pages.

2.1 Key Features

  • Integrated Charge Presets: Combined with adaptive charge logic, well-suited for common battery types like LiFePO4, Gel, and flooded lead-acid.
  • Flexible Application: Compatible with 12V/24V/36V/48V system voltage.
  • Multi-stage Charge Algorithm: Specifically engineered to optimize each recharge cycle and charge maintenance over extended periods.
  • MPP Tracking Technology: Tracks the array's maximum power point voltage (Vmp) to ensure maximum power is harvested from the array throughout the day.
  • High Efficiency: Innovative MPPT technology with up to 99% tracking efficiency and 98% peak conversion efficiency, resulting in lower power usage, less heat, and cooler operation.
  • Adaptive Boost Charge: Monitors battery response during initial charging to determine appropriate boost charge duration, ensuring full recharge without excessive voltage time.
  • Durable and Safe: Includes protections such as maximum charging current limit, PV array short circuit, PV input overcurrent, controller overload, load short circuit, PV reverse polarity, battery reverse polarity, and over-temperature protection.
  • Silent Operation: No cooling fan or moving parts; cooling is via natural convection.
  • Lithium Battery Activation: Supports Li-ion (LiFePO4) batteries. The controller can activate a protected lithium battery using solar panel energy within its protection voltage and current range.

Video: Overview of the PowMr MPPT Solar Charge Controller, highlighting its compact design, LCD display, heat sink, battery type support, 3-stage charging, and protection features.

2.2 Product Components

PowMr MPPT 60A Solar Charge Controller

Image: PowMr MPPT 60A Solar Charge Controller, showing two controllers connected to batteries, with text indicating parallel connection capability (up to 12 units) and a maximum VOC of 160V.

Controller Component Overview
No.Component
1LCD display screen
2Function keys
3PV input terminal
4Battery terminal
5Load terminal
6Mount hole
7Heat sink

3. Installation and Connection

3.1 Unpacking and Inspection

Before unpacking the controller, check whether the package is damaged. After unpacking, check whether the contents of the package are damaged or missing. You should have received the following items:

  • Controller
  • User manual
  • Screws/bolts

3.2 Preparing for Installation

The controller is designed for wall mounting using the flanges that protrude from the heatsink. Select a suitable and safe location with good natural airflow/ventilation. Ensure a minimum clearance of 75mm above and below the controller for proper heat dissipation. Install on a non-flammable substrate, away from heat-sensitive items, flammable liquids, or gasses. The controller is for indoor use only. Do not install on top of or directly above the battery, or in a sealed compartment with the battery, as batteries can emit explosive gases. Do not cover the controller.

Solar Connect Diagram

Image: Solar Connect Diagram, illustrating the connection of solar panels, MPPT controller, battery, load, and inverter. This diagram also shows how multiple controllers can be connected in parallel.

3.3 Things You Need

Required Items for Installation
ProductQuantity
POW-M60-PRO Controller (included)1
DC-cable to connect the positive DC connection (+) of the controller to the positive pole of the DC-distribution3
DC-cable to connect the negative DC connection (-) of the controller to the negative pole of the DC-distribution3
DC breaker3
Screws / bolts (Ø5mm) to mount the cabinet to a surface. Use mounting materials which are suitable to carry the weight of the controller. (included)4
PV array. See section "2.5 PV Module Selection" for the configuration of solar panels1
Battery pack.1

3.4 Wiring Specification and Breaker Type

Determine the maximum PV input current based on the configured system voltage and by referring to "6 Technical Specification". The voltage in series shall not exceed maximum PV input open-circuit voltage.

Recommended Input Wire Diameter and Switch Type for DC Output (DC Load)
ModelMax. DC output CurrentWire DiameterCircuit Breaker Spec
POW-M60-PRO8A14AWG2P-8A

The cables and circuit breakers for the battery should be selected based on the maximum charging current of the battery you connected.

3.5 PV Module Selection

When selecting proper PV modules, consider the following parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the controller.
  2. Open circuit Voltage (Voc) of PV modules should be higher than the Min. battery voltage.
Max. PV Array Open Circuit Voltage
Controller modePOW-M60-PRO
Max. PV array open circuit voltage of controller160V

3.6 Wiring Precautions

  • Installation and connection work must be performed by a licensed electrician.
  • To avoid short circuit and reverse polarity connection, ensure that the positive cable is connected to the positive polarity port (+) of the device, and the negative cable is connected to the negative polarity port (-) of the device.
  • Too-thin cables and/or loose connections can cause dangerous overheating of the cables and/or terminals. Therefore, tighten all connections well to limit transition resistance. Use cables of the correct size. Refer to "2.4 Wiring Specification and Breaker Type" section for details.
  • Do not connect the inverter to the load side of the controller. Otherwise, irreversible damage may be caused to the device. If an inverter is needed, refer to the system application diagram.
Parallel Operation Schematic

Image: Parallel Operation Schematic, showing how up to 12 MPPT controllers can be connected in parallel to a single battery bank (12V/24V/36V/48V System) and multiple solar arrays. Includes labels for Parallel Communication Cable, Positive Power Cable, and Negative Power Cable.

3.7 Installation and Connection Step-By-Step

  1. Mark the position of the mounting spots on the wall based on the mount holes of the controller. Then make 4 mounting holes in the wall with an electric drill according to the spots. Refer to the "2.2 Preparing for Installation" section for installation locations.
  2. Insert the expansion rubber screw plug into the mounting holes.
  3. Mount the controller vertically to the ground with terminals facing down; secure using the 4 mounting holes/slots on the base. To aid installation, it is recommended to 'hang' the unit using the 2 upper screws and then add the 2 lower screws, before fully securing all 4 screws. Recommend screws size is M5.
  4. Battery Connection: Connect the battery to the controller with the cables.
  5. PV Connection: Connect the PV array to the controller with the cables.
  6. DC Output Connection: Connect the load to the controller with the cables.
  7. Check before starting up: See the wiring diagram below for details. If everything is all right, and all the wires are firmly connected, close the circuit breakers at the battery side, PV module side, and load side in sequence to startup controller.

WARNING: Risk of electric shock!

Make sure that all the power is turned off before performing any operations, and then follow the corresponding inspections and operations.

Wiring Diagram for Solar Charge Controller

Image: A simplified wiring diagram showing the connection sequence: Battery (1), PV Array (2), and Load (3) to the solar charge controller.

4. Charging Mode

The charging controller is equipped with an intelligent 3-stage charge characteristic for optimal battery charging. When switched on, the controller always starts at the Bulk stage.

Efficient Charging Diagram

Image: Efficient Charging diagram, illustrating 99% High Tracking Efficiency and 98% Peak Conversion Efficiency. It shows the 3-stage charging process (Bulk Charge, Absorption Charge, Float Charge) and notes a maximum charging current of 60A with an adjustable range of 2-60A.

4.1 Multi-Stage Charging Algorithm

  • Bulk Charge: The battery is charged at maximum current until the voltage reaches the configured boost charge voltage. The duration depends on the battery's discharge level, capacity, and charge current.
  • Boost Charge: The battery is charged at the configured boost charging voltage, with the charge current slowly decreasing as the battery approaches full charge. The default boost stage duration is adaptive and intelligently varied based on the battery's discharge level. If the battery is in full state, this stage will be entered directly. The duration of this stage is 30 minutes.
  • Float Charge: After the boost charging stage, the controller reduces the charging current to maintain the battery at the floating charging voltage, ensuring a full charge state. In this stage, loads can draw power from the solar panel. If loads exceed the solar power, the system will exit float charge and return to bulk charge if the battery voltage drops below the Recharge Voltage.

4.2 Applicable Battery Types

Applicable Battery Types Table

Image: Applicable Battery Type table, listing 14 integrated charge presets for various battery types including Sealed Lead Acid, Gel Sealed Lead Acid, Flooded Lead-Acid, Lithium Iron Phosphate (4, 7, 8, 15, 16 strings), Ternary Lithium-ion (3, 6, 7, 13, 14 strings), and User-Defined.

5. Operation Instruction

5.1 Icon Display on LCD Screen

LCD Display Icons and Functions
No.Function
1Day or night indicating icon
2Indicates the remaining battery capacity
3Working mode
4Periodic running status of the load and warning state
5Indicate PV input voltage/power
6Indicate Current battery voltage/Charging current/Equipment temperature/Battery calibration voltage/Battery type/Boost charging voltage/Float charging voltage/Low DC cut-off recovery voltage/ Low DC cut-off voltage.
7Indicate working mode of load.

5.2 Function Keys

Controller Function Keys
IconDescription
PV / ▦To switch the PV input parameters information
BAT / ▲To switch the charging information/ Return the previous option.
DC / ▼To adjust DC output mode and DC output operation duration/ Enter the next option.
SET / ⚙Confirm and reserve the settings.

5.3 Browse and Configuration Step-By-Step

After cables are connected and the device is started, perform the initial configuration according to the following steps based on the actual situation.

NOTICE:

  • The screen will automatically turn off the backlight after about 25 seconds without pressing a button to save power consumption. The backlight display can be activated by operating any key again.

5.3.1 PV side

Step 1. Checking PV input Information: Press "PV / ▦" key to switch PV information, which is PV input voltage and PV input power in sequence.

5.3.2 Battery side

Step 1. Checking Battery Information: Press "BAT / ▲" key to switch battery information, which is current battery voltage, charging current, equipment temperature, battery calibration voltage, battery type, boost charging voltage, float charging voltage, low DC recovery cut-off voltage, low DC cut-off voltage in sequence.

Step 2. Calibrate battery voltage: The battery calibration voltage parameter is used to correct the current battery voltage measured by the controller.

  1. Once the parameter switches to "battery calibration voltage" item, press and hold "BAT / ▲" key to enter the battery voltage calibration setting.
  2. Then press the "BAT / ▲" or "DC / ▼" keys to calibrate the battery voltage parameters of the controller according to the battery voltage measured by the multimeter. Finally press "SET / ⚙" to confirm.

Step 3. Select the Battery Type: Adjust battery type parameters based on the battery you connected:

  1. Once the parameter switches to the battery type item, press and hold "BAT / ▲" key to enter the battery type adjustment setting.
  2. Then press "BAT / ▲" or "DC / ▼" adjust battery type, finally press "SET / ⚙" to confirm. The operating voltage varies according to battery types.
  3. For details, please refer "4.5.2 Battery parameters of different types" section.
Battery Type Selection
SequenceDisplayBattery Type
1SELSealed lead acid battery
2GELColloidal lead acid battery
3FLdVented lead acid battery
4L04Lithium iron phosphate battery
5L07Lithium iron phosphate battery
6L08Lithium iron phosphate battery
7L15Lithium iron phosphate battery
8L16Lithium iron phosphate battery
9N03Ternary lithium battery
10N06Ternary lithium battery
11N07Ternary lithium battery
12N13Ternary lithium battery
13N14Ternary lithium battery
14USEUser-defined

Step 4. Customize configured voltage parameters: This step is required only when the battery type is set to "USE".

  1. Once the battery type is set to "USE", the configurable parameters are presented in the following order. Increment of each click is 0.1V.
Customizable Voltage Parameters
ItemSetting Range
Nominal system voltage12V/24V/36V/48V (optional)
Boost charging voltage10.0~17.0V
Float charging voltage10.0~17.0V
Low DC cut-off recovery voltage10.0~15.0V
Low DC cut-off voltage10.0~15.0V
  1. Press "BAT / ▲" key to select parameter item which you need to adjust.
  2. Then press and hold "BAT / ▲" key to enter related parameter, then press "BAT / ▲" or "DC / ▼" adjust voltage value.
  3. Finally press "SET / ⚙" to confirm. Refer "4.5 Key Points Battery Parameter Settings" section for the logic for setting battery voltage parameters.

NOTICE:

  • The 5 parameters as shown above can be set only when the battery type is "USE". If "USE" is selected, you need to manually set the system voltage.

CAUTION:

  • The preceding parameter ranges apply to the 12V battery. When the connected battery voltage is 24V/36V/48V, the range values are 2/3 times of this range, respectively. And the LCD only display the voltage of the 12V battery.

WARNING:

  • The above Settings must follow the following logic: Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage.

5.3.3 Load side

Step 1. Configure load enable duration:

  1. Press and hold "DC / ▼" key to enter the load mode setting.
  2. Then press "BAT / ▲" or "DC / ▼" adjust load state or load enable duration.
  3. Finally press "SET / ⚙" to confirm.
  • 00H: The solar light control mode. (Loads start to supply power after dark and stop working after dawn.)
  • 24H (Default): Turn on load immediately. A short press of the "DC / ▼" key immediately shuts off the load output.
  • 01H-23H: Adjust the load enable duration. Setting range is from 0 hour to 24 hours. Increment of each click is 1 hour.

5.4 Working Mode

Controller Working Modes
CodeDescription
3.0Night mode, no charging
4.0Bulk charging mode (MPPT mode)
7.0Boost charging mode
8.0Float charging mode

5.5 Key Points Battery Parameter Settings

5.5.1 The logic for setting battery voltage parameters:

  1. Before you customize battery parameters, confirm the following parameters of the connected battery:
    • Max charging voltage
    • Discharging protection voltage
  2. After confirming the battery information, you can set the 4 key parameters according to the following logic: Max. charging voltage > Boost charging voltage > Float charging voltage > Low DC cut-off recovery voltage > Low DC cut-off voltage > Discharge protection voltage

6. Protection

6.1 Protection Provided

Protection Features and Behavior
ProtectionBehavior
PV Array Short CircuitWhen PV short circuit occurs, the controller will stop charging. Clear it to resume normal operation.
PV Input OvercurrentThe controller will limit the battery charging current to the maximum battery current rating. Therefore, an overcurrent solar array will not operate at peak power.
Controller OverloadIf the current exceeds the maximum load current rating of 21A, the controller will disconnect the load. Overloading must be cleared up by reducing the load and restarting the controller.
Load Short CircuitFully protected against the load wiring short-circuit. Once the load short circuit (more than quadruple rated current), the load short circuit protection will start automatically. After 5 automatic load reconnect attempts, the faults must be cleared by restarting the controller.
PV Reverse PolarityThe controller will not operate if the PV wires reverse polarity. Wire them correctly to resume normal controller operation.
Battery Reverse PolarityThe controller will not operate if the battery wires reverse polarity. Wire them correctly to resume normal controller operation.
Over-TemperatureIf the temperature of the controller heat sink exceeds 65°C, the controller will automatically start reducing the charging current and shut down when temperature exceeds 80°C.

7. Maintenance

The following inspections and maintenance tasks are recommended at least two times per year for best performance:

  • Make sure controller is firmly installed in a clean and dry ambient.
  • Make sure no block on air-flow around the controller. Clear up any dirt and fragments on radiator.
  • Check all the naked wires to make sure insulation is not damaged for serious solarization, frictional wear, dryness, insects or rats etc. Repair or replace some wires if necessary.
  • Tighten all the terminals. Inspect for loose, broken, or burnt wire connections.
  • Confirm that all the system components are ground connected tightly and correctly.
  • Confirm that all the terminals have no corrosion, insulation damaged, high temperature or burnt/discolored sign, tighten terminal screws to the suggested torque.
  • Check for dirt, nesting insects and corrosion. If so, clear up in time.

WARNING: Risk of electric shock!

Make sure that all the power is turned off before performing any operations, and then follow the corresponding inspections and operations.

8. Troubleshooting

In case of a failure, the controller display shows an error signal to help you find its source. The controller is also equipped with an integrated alarm function (refer to section 3.1 Alarm Function).

Troubleshooting Guide
Fault codePossible CauseWhat to do
18Input PV voltage is lowIncrease the number of photovoltaic panels; or increase the photovoltaic input voltage value in series.
60Over-temperature protectionWhen the temperature of the device is cooled below the recovery temperature, normal charge and discharge control is resumed.
63Battery voltage is highMeasure whether the battery voltage exceeds the rated voltage and turn off the photovoltaic array air switch.
65Battery voltage is lowCharge the battery and wait until the battery voltage is higher than the low voltage cut-off voltage recovery point, refer to "4.5.2 Battery parameters of different types" section for detail.
71Input PV voltage is highReduce the number of PV panels connected to the controller to reduce the PV input; or reduce the voltage or current value by changing the series or parallel mode.
73Over-charging currentReduce the number of PV panels connected to the controller to reduce the PV input; or reduce the voltage or current value by changing the series or parallel mode.

9. Technical Specifications

PowMr POW-M60-PRO Technical Specifications
CategoryParameterValue (POW-M60-PRO)
PV InputMax. Input Power (12V system)720W
Max. Input Power (24V system)1440W
Max. Input Power (36V system)2100W
Max. Input Power (48V system)2800W
Max. PV input open circuit voltage160Vdc
Input Voltage RangeFor 12V System20V~80V
For 24V System37V~105V
For 36V System50V~160V
For 48V System72V~160V
Charge ModeCharging TechnologyMPPT
Charge Algorithm3-Stage
Nominal System Voltage12V/24V/36V/48V
Battery Voltage Range9~70V
Rated Charging Current60A
Conversion EfficiencyConversion Efficiency≤98%
MPP Tracking EfficiencyMPP Tracking Efficiency>99%
Self-consumptionSelf-consumption0.7W-1.2W
DC OutputRated Output Current6A
Max. DC Output Current8A
Max. Capacitive Load Capacity10000μF
EnvironmentOperating Temperature Range-35°C~+45°C
Humidity Range≤95%, Non-condensing
Altitude<3000m
General SpecificationProtection ClassIP32
Dimension230*165*72mm (9.1*6.5*2.8in)
Net Weight1.33kg (2.9lbs)

10. User Tips

  • LiFePO4 Battery Compatibility: This controller is fully compatible with LiFePO4 batteries and offers specific charge cycle settings for them.
  • Custom Battery Settings: The controller allows for user-defined battery settings, providing flexibility for various battery chemistries and configurations (e.g., 8S Lipo).
  • Solar Panel Sizing: The controller supports a maximum PV input voltage of 160Vdc and a maximum PV input wattage of 2800W. For example, three 100W, 18V panels (total 300W, 54V) are well within the controller's limits.

11. Support and Contact Information

For technical support or inquiries, please contact:

  • Manufacturer: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.